{"product_id":"serpentin-devaporateur-goodman-capfa3626b3-a-3-tonnes","title":"GOODMAN CAPFA3626B3 Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003eGoodman CAPFA3626B3 coil: 3 tons in a narrow 17-1\/2 in cabinet\u003c\/h2\u003e\n\u003cp\u003eSome furnaces are slim. You find them in row houses, small bungalows from the sixties and utility closets where every inch counts. For those units, the \u003cstrong\u003eCAPFA3626B3\u003c\/strong\u003e is the 3-ton model in the Goodman CAPFA series that best fits the footprint: its cabinet is only 17-1\/2 in wide.\u003c\/p\u003e\n\u003cp\u003eIt is a 3-ton (36,000 BTU\/h) cased A-coil running on \u003cstrong\u003eR-32 refrigerant\u003c\/strong\u003e, designed to mount on a furnace or a blower cabinet. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhy width often decides the model\u003c\/h3\u003e\n\u003cp\u003eWhen shopping for a coil, people think of tons first. Yet in the field, width is what causes trouble first. A cabinet wider than the furnace forces us to build a transition, and a transition costs time and space. A cabinet well matched to the furnace sits straight, with short connections and a seal that is easier to get right.\u003c\/p\u003e\n\u003cp\u003eThe CAPFA3626B3 measures 17-1\/2 × 26 × 21 in. It therefore suits compact furnaces whose air rises through a narrow plenum. If yours is wider, we measure it at the visit and tell you honestly whether another model in the series would make more sense.\u003c\/p\u003e\n\n\u003ch3\u003eHow it compares with its neighbours in the series\u003c\/h3\u003e\n\u003cp\u003eThree coils in the family offer 3 tons. They share the A shape, R-32 refrigerant, the piston metering device and the same height. Only the width sets them apart:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCAPFA3626B3 (this one):\u003c\/strong\u003e 17-1\/2 in, the narrowest of the three;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAPFA3626C3:\u003c\/strong\u003e 21 in, for medium-width furnaces;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAPFA3626D3:\u003c\/strong\u003e 24-1\/2 in, for large furnaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAbove it, the series also offers three 3.5-ton models in these same widths, a 4-ton model at 21 in and a 5-ton model at 24-1\/2 in. Below it, there is a single 2.5-ton coil, at 24-1\/2 in. The CAPFA3626B3 is therefore the only one to combine 3 tons with the slimmest width in the whole range.\u003c\/p\u003e\n\n\u003ch3\u003eA typical installation day\u003c\/h3\u003e\n\u003cp\u003eIn the morning, we cut the power, remove the old coil if there is one, and measure the plenum. The insulated cabinet is then mounted on the furnace and sealed to the ducts. Meanwhile, the outdoor unit is set on its bracket, and the copper piping is carefully brazed between the two.\u003c\/p\u003e\n\u003cp\u003eIn the afternoon, we pressure-test with nitrogen, pull a vacuum, connect the condensate drain and the thermostat, then start the system. Before leaving, we adjust the airflow and go over the basic settings with you.\u003c\/p\u003e\n\n\u003ch3\u003eThe \"add-on\" mode: keeping your furnace\u003c\/h3\u003e\n\u003cp\u003eWith a heat pump, the coil and the furnace work as a team. The heat pump supplies most of the heat when the outdoor air is not too cold. The furnace, with its blower and filters, stays in place and takes over below a temperature threshold that we program with you.\u003c\/p\u003e\n\u003cp\u003eThe advantage is simple: no new ducts, no opened walls, and a backup heat source that already knows your home.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the coil doesn't tell you on its own\u003c\/h3\u003e\n\u003cp\u003eThe CAPFA3626B3 has no efficiency rating of its own. The published ratings belong to the matched system, the one that links this coil to a specific outdoor unit under an AHRI number. We confirm that number before ordering.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNo R-32 match with this coil is listed with ENERGY STAR (dataset w7cv-9xjt, checked on 2026-11-26); AHRI remains the reference for the outdoor unit chosen.\u003c\/li\u003e\n\u003cli\u003eGoodman offers a 10-year limited parts warranty, with online registration within 60 days of installation (not required in Quebec).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical data at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: CAPFA3626B3, cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003enominal capacity: 3 tons (36,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-32, leak sensor designed for the life of the coil;\u003c\/li\u003e\n\u003cli\u003emetering device: piston;\u003c\/li\u003e\n\u003cli\u003epositions: upflow or downflow;\u003c\/li\u003e\n\u003cli\u003e3\/8 in liquid connection, 7\/8 in suction connection;\u003c\/li\u003e\n\u003cli\u003econdensate drain: 3\/4 in FNPT, primary and secondary;\u003c\/li\u003e\n\u003cli\u003edimensions W × H × D: 17-1\/2 × 26 × 21 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhich home suits a 3-ton coil?\u003c\/h3\u003e\n\u003cp\u003eThe 3-ton size serves a large share of the bungalows and cottages in the region: furnace in the basement, ducts to every room, and an old central air conditioner or window units in summer. A two-storey row house with generous windows also falls in this category.\u003c\/p\u003e\n\u003cp\u003eA load calculation remains the best way to settle the question. A system that is too big shuts off and restarts constantly; one that is too small runs out of breath on hot days. We look for the happy medium.\u003c\/p\u003e\n\n\u003ch3\u003eWhat you gain from an insulated cabinet\u003c\/h3\u003e\n\u003cp\u003eThe CAPFA3626B3 ships in an insulated cabinet, ready to install on the furnace. This casing limits condensation on the walls and reduces air leaks between the plenum and the coil. Installation is faster than with an uncased coil that has to be enclosed on site, and the seal is easier to control.\u003c\/p\u003e\n\u003cp\u003eIn a tight space, that is a real advantage: fewer materials to handle, fewer joints to seal, fewer places for air to sneak through.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the coil be used for heating?\u003c\/strong\u003e Yes, with a heat pump. With a central air conditioner, it only provides cooling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan my old air conditioner stay?\u003c\/strong\u003e Generally no: R-32 requires the outdoor unit specified by the manufacturer, and we install the two together.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat if my furnace is wider than 17-1\/2 in?\u003c\/strong\u003e We measure the unit and, if needed, build an insulated transition on site, or steer you toward a wider model.\u003c\/p\u003e\n\n\u003ch3\u003eThe small constraints that matter in a tight space\u003c\/h3\u003e\n\u003cp\u003eIn a utility closet or a basement corner, you can't manoeuvre as you would in a large room. We plan access to the filter, the pan and the connections before we even start, and we leave the clearance a technician needs to come back for maintenance without taking everything apart. A system you can reach is a system you maintain.\u003c\/p\u003e\n\u003cp\u003eWe also avoid unnecessary elbows in the piping and insulate the refrigerant lines to limit condensation that could drip onto finished floors.\u003c\/p\u003e\n\n\u003ch2\u003eOur team, your project\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is covered by RBQ licence 5645-9605-01. Your project includes measuring the furnace, checking the blower and the electrical panel, installing the coil, the outdoor unit, the piping, the vacuum and commissioning.\u003c\/p\u003e\n\n\u003ch3\u003ePoints to confirm before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil and the outdoor unit both run on R-32 and are installed together.\u003c\/li\u003e\n\u003cli\u003eEfficiency ratings apply to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe 17-1\/2 in width and the blower must suit your furnace; we check everything on site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHydro-Québec incentives\u003c\/h3\u003e\n\u003cp\u003eEligibility depends on the complete system and not on the coil alone. We consult the official list against the installation date, then explain what applies.\u003c\/p\u003e\n\n\u003ch3\u003eGet your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402718343460,"sku":"CAPFA3626B3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAPFA_CAPFA3626B3_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765974","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-capfa3626b3-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}