{"product_id":"serpentin-devaporateur-goodman-capfa4226b3-a-3-5-tonnes","title":"GOODMAN CAPFA4226B3 Evaporator A-Coil | 3.5 Tons","description":"\u003ch2\u003eWhen 3.5 tons must fit in 17-1\/2 in: the CAPFA4226B3\u003c\/h2\u003e\n\u003cp\u003eHere is a configuration that raises eyebrows: a capacity of 3.5 tons (42,000 BTU\/h) in the narrowest cabinet in the series. That is precisely what the \u003cstrong\u003eCAPFA4226B3\u003c\/strong\u003e offers, a Goodman cased evaporator A-coil running on \u003cstrong\u003eR-32 refrigerant\u003c\/strong\u003e. It measures 17-1\/2 in wide, 26 in tall and 21 in deep.\u003c\/p\u003e\n\u003cp\u003eYou find it in homes that need a lot of cooling but whose furnace is slim: large single-storey homes that are compact in width, cottages with a narrow plenum, townhouses with many rooms. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the capacity asks of the house\u003c\/h3\u003e\n\u003cp\u003eThe more the capacity goes up, the more air has to circulate through the coil. At 3.5 tons, the system calls for more generous airflow than the 2.5-ton or 3-ton sizes. That airflow comes from the furnace blower, and it has to be able to deliver it without straining.\u003c\/p\u003e\n\u003cp\u003eDuring the visit, we therefore measure three things: the blower capacity, the size of the plenum and the condition of the return air. A narrow plenum is not an obstacle in itself, but it requires careful attention to air distribution to avoid cold spots and noise.\u003c\/p\u003e\n\n\u003ch3\u003eQuick read of the four 3.5-ton and 3-ton models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCAPFA4226B3 (this one):\u003c\/strong\u003e 3.5 tons, 17-1\/2 in;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAPFA4226C3:\u003c\/strong\u003e 3.5 tons, 21 in;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAPFA4226D3:\u003c\/strong\u003e 3.5 tons, 24-1\/2 in;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAPFA3626B3:\u003c\/strong\u003e 3 tons, 17-1\/2 in, the same width with a lower capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 3-ton coil at 17-1\/2 in is enough if your needs remain modest. This one is preferable if the house is large, has lots of glass or faces south. For even bigger homes, the series offers a 4-ton model at 21 in and a 5-ton model at 24-1\/2 in.\u003c\/p\u003e\n\n\u003ch3\u003eAnatomy of the cabinet\u003c\/h3\u003e\n\u003cp\u003eThe insulated casing of the CAPFA4226B3 encloses the A-coil, the drain pan and the connections. Two sloped faces meet at the top: air rises in the centre and passes through both sides. Upflow and downflow positions are provided by the manufacturer. The liquid connection is 3\/8 in and the suction is 7\/8 in, while the pan drains through a 3\/4 in FNPT drain with a primary and a secondary outlet.\u003c\/p\u003e\n\u003cp\u003eAn R-32 refrigerant sensor, designed to last as long as the coil, watches for possible leaks.\u003c\/p\u003e\n\n\u003ch3\u003eHeat pump or air conditioner?\u003c\/h3\u003e\n\u003cp\u003eBoth choices are possible with this coil. Paired with a central air conditioner, it only cools in summer. Paired with a heat pump, it also heats in winter through the existing ducts, with the furnace staying on as backup for deep cold.\u003c\/p\u003e\n\u003cp\u003eThe choice depends on your current heat source. If you heat with electricity, the heat pump offers a notable gain; if you heat with gas, we compare the two options with you before recommending one.\u003c\/p\u003e\n\n\u003ch3\u003eEfficiency, ENERGY STAR and warranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil has no efficiency rating on its own; the ratings belong to the matched system and its AHRI number.\u003c\/li\u003e\n\u003cli\u003eNo R-32 match with this coil is listed with ENERGY STAR (dataset w7cv-9xjt, checked on 2026-11-26).\u003c\/li\u003e\n\u003cli\u003eGoodman's limited warranty covers parts for 10 years, with online registration within 60 days (not required in Quebec).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCAPFA4226B3 features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003enominal size: 3.5 tons (42,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-32;\u003c\/li\u003e\n\u003cli\u003emetering device: piston;\u003c\/li\u003e\n\u003cli\u003edimensions: 17-1\/2 × 26 × 21 in;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid and 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003edrain: 3\/4 in FNPT, primary and secondary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat we see in summer in a large house\u003c\/h3\u003e\n\u003cp\u003eIn a cottage on the South Shore, the upstairs bedrooms are often the last to cool down. A well-sized coil, with a blower that delivers the required airflow, reduces those differences. If the bedrooms stay warm despite good equipment, the distribution is often the cause, and we can propose precise adjustments to the duct network.\u003c\/p\u003e\n\n\u003ch3\u003eA word on noise and comfort\u003c\/h3\u003e\n\u003cp\u003eA 3.5-ton system moves a lot of air. If the ducts are too tight, the rush of air becomes audible at the grilles. We therefore measure the cross-section of the main ducts and the returns, then recommend a blower speed that balances comfort and quiet. This work is all the more useful with a narrow cabinet, where the plenum can concentrate the airflow.\u003c\/p\u003e\n\u003cp\u003eAn extra return air on the upper floor, for example, can relieve the whole network without changing equipment.\u003c\/p\u003e\n\n\u003ch3\u003eWhen to choose a wider model instead\u003c\/h3\u003e\n\u003cp\u003eIf your furnace measures 21 in or 24-1\/2 in, the CAPFA4226C3 or the CAPFA4226D3 offers the same capacity without a transition. We always prefer a cabinet that matches the existing unit. The CAPFA4226B3 is the right choice when the 17-1\/2 in width truly matches the furnace, not simply because it is the most compact.\u003c\/p\u003e\n\n\u003ch3\u003eA look at the energy bill\u003c\/h3\u003e\n\u003cp\u003eA coil well matched to its outdoor unit and to the blower works less hard for the same comfort. Conversely, a rough match makes the compressor run longer. That is one of the reasons we insist on the AHRI number: it attests that the components were tested together.\u003c\/p\u003e\n\n\u003ch3\u003eWhat people ask us most\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes R-32 refrigerant change anything for me?\u003c\/strong\u003e Mainly one point: the coil and the outdoor unit must share the same refrigerant, so they are replaced together.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat if the furnace is wide?\u003c\/strong\u003e We build an insulated transition on site, or we recommend a wider model in the series.\u003c\/p\u003e\n\n\u003ch3\u003eHow we handle a narrow plenum\u003c\/h3\u003e\n\u003cp\u003eA 17-1\/2 in plenum concentrates the air on a reduced surface. For the coil to work well, the air has to pass through it evenly, with no dead zones or currents that bypass it. We check that the cabinet is well centred, that the joints are tight and that the transition to the ducts doesn't create a choke point. Careful work at this spot translates into less noise and better cooling.\u003c\/p\u003e\n\n\u003ch2\u003eComplete installation by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. We measure the furnace, check the blower and the panel, install the coil, install the outdoor unit, braze the piping, pressure-test with nitrogen, pull a vacuum, connect the drain and the thermostat, then adjust the airflow.\u003c\/p\u003e\n\n\u003ch3\u003eTo confirm before placing your order\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil and the outdoor unit must both be R-32.\u003c\/li\u003e\n\u003cli\u003ePublished ratings apply to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the airflow of 3.5 tons, and the furnace must be able to take the 17-1\/2 in cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eEligibility for Hydro-Québec programs depends on the complete system. We check the official list against the installation date and tell you what applies.\u003c\/p\u003e\n\n\u003ch3\u003eEstimate and financing\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402705891620,"sku":"CAPFA4226B3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAPFA_CAPFA4226B3_00_3_5_TONNES_42000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765974","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-capfa4226b3-a-3-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}