{"product_id":"serpentin-devaporateur-goodman-capfa4226d3-a-3-5-tonnes","title":"GOODMAN CAPFA4226D3 Evaporator A-Coil | 3.5 Tons","description":"\u003ch2\u003eThe CAPFA4226D3 in brief: 3.5 tons, 24-1\/2 in wide, R-32\u003c\/h2\u003e\n\u003cp\u003eIf you want a quick answer: the \u003cstrong\u003eCAPFA4226D3\u003c\/strong\u003e is the Goodman 3.5-ton (42,000 BTU\/h) coil in the wide 24-1\/2 in cabinet. It measures 24-1\/2 × 26 × 21 in, uses \u003cstrong\u003eR-32 refrigerant\u003c\/strong\u003e, mounts on a furnace or a blower cabinet, and connects to a Goodman outdoor unit of the same capacity.\u003c\/p\u003e\n\u003cp\u003eFor the details, the rest of the page answers the questions asked by homeowners in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e before choosing a system.\u003c\/p\u003e\n\n\u003ch3\u003eWhy this model rather than another?\u003c\/h3\u003e\n\u003cp\u003eThere are two main reasons, and they come down to two words: width and capacity.\u003c\/p\u003e\n\u003cp\u003eOn width, 24-1\/2 in matches the largest furnaces. On those units, a narrower cabinet would be surrounded by a transition that complicates the installation. On capacity, 3.5 tons is enough for spacious homes without climbing to the 4-ton or 5-ton size. It is a model suited to large single-storey homes and cottages with plenty of windows.\u003c\/p\u003e\n\n\u003ch3\u003eNext to its siblings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eAgainst the CAPFA4226B3 and the CAPFA4226C3:\u003c\/strong\u003e same 3.5-ton capacity, but a 17-1\/2 in or 21 in cabinet. The CAPFA4226D3 is the widest of the trio.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAgainst the CAPFA3626D3:\u003c\/strong\u003e same 24-1\/2 in width, but 3 tons instead of 3.5 tons.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAgainst the CAPFA6030D3:\u003c\/strong\u003e same width, but 5 tons. It suits much larger homes.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAgainst the CAPFA3022D3:\u003c\/strong\u003e same width, but 2.5 tons, for more modest homes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe practical rule: first find the width of your furnace, then let the load calculation set the capacity among the models that fit that width.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the coil does in the system\u003c\/h3\u003e\n\u003cp\u003eAn evaporator coil is a heat exchanger. Cold refrigerant circulates in its tubes, the blower pushes the house air over the fins, and the heat in the air passes into the refrigerant. The result: cooler, drier air distributed through the ducts.\u003c\/p\u003e\n\u003cp\u003eTo play this role well, the coil depends on its metering device. On this model, it is a piston, a simple and robust device that doses the refrigerant sent into the tubes.\u003c\/p\u003e\n\n\u003ch3\u003eHeat pump in \"add-on\" mode\u003c\/h3\u003e\n\u003cp\u003eIn winter, if the outdoor unit is a heat pump, the cycle reverses. The coil becomes the heat source that warms the house air. The furnace, which keeps its blower, filters and heating elements, steps in only when the outdoor temperature falls below a threshold set with you.\u003c\/p\u003e\n\u003cp\u003eThis approach avoids replacing the entire heating installation. It lowers the bill in mild periods and keeps a heat reserve for deep cold.\u003c\/p\u003e\n\n\u003ch3\u003ePoints on which we stay transparent\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil has no efficiency rating of its own; the published values are those of the matched system.\u003c\/li\u003e\n\u003cli\u003eNo R-32 match with this coil is listed with ENERGY STAR (dataset w7cv-9xjt, checked on 2026-11-26). AHRI remains the reference for the outdoor unit.\u003c\/li\u003e\n\u003cli\u003eGoodman advertises a 10-year limited parts warranty, with online registration within 60 days of installation (not required in Quebec).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCAPFA4226D3 spec sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil, CAPFA range;\u003c\/li\u003e\n\u003cli\u003esize: 3.5 tons (42,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-32, leak sensor for the life of the coil;\u003c\/li\u003e\n\u003cli\u003emetering device: piston;\u003c\/li\u003e\n\u003cli\u003epositions: upflow or downflow;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid, 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003edrain: 3\/4 in FNPT, primary and secondary;\u003c\/li\u003e\n\u003cli\u003edimensions: 24-1\/2 × 26 × 21 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat to look at in your home\u003c\/h3\u003e\n\u003cp\u003eThree points determine success: the blower, which must deliver the airflow of a 3.5-ton system; the plenum, which must receive a 24-1\/2 in cabinet; and the ducts, especially the return air, which must pass the necessary volume. We measure each point rather than assume.\u003c\/p\u003e\n\u003cp\u003eIf one of the three poses an obstacle, we say so out loud and look for the simplest fix before talking about replacement.\u003c\/p\u003e\n\n\u003ch3\u003eShort answers\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan it heat?\u003c\/strong\u003e Yes, with a heat pump. \u003cstrong\u003eDo I have to change my air conditioner?\u003c\/strong\u003e Yes, along with the coil, because R-32 requires the specified outdoor unit. \u003cstrong\u003eWhat if the width differs?\u003c\/strong\u003e We build an insulated transition on site.\u003c\/p\u003e\n\n\u003ch3\u003eAn example in a South Shore home\u003c\/h3\u003e\n\u003cp\u003eA large single-storey home on the South Shore, built around a wide furnace, with a half-finished basement and windows facing south. In summer, hot air settles in the living room, and the upper floor is never quite cool. The owner wants a central system without cutting new ducts.\u003c\/p\u003e\n\u003cp\u003eIn this case, a CAPFA4226D3 mounted directly on the furnace, without a transition, delivers the capacity needed with the ducts in place. If the owner also wants to cut heating consumption, the outdoor unit chosen is a heat pump, and the furnace stays on as backup.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we adjust after installation\u003c\/h3\u003e\n\u003cp\u003eOnce the system is running, we measure the air temperature at the outlet and the inlet, check the drain and test the thermostat. We then set the blower speed according to the home's ducts. This final step balances the airflow, limits noise at the grilles and makes sure each room gets its share of air.\u003c\/p\u003e\n\u003cp\u003eFinally, we give you the contact details of the technician who did the work, so you know whom to call if you have a question.\u003c\/p\u003e\n\n\u003ch2\u003eAirGreen's work, from the visit to commissioning\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01. Main steps:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasurement of the furnace, check of the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003emounting of the cabinet, sealing of the duct connections;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed piping, nitrogen test, vacuum;\u003c\/li\u003e\n\u003cli\u003econnection of the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and explanations at the house.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eOne last benchmark: this coil is not a prestige choice, it is a fitting choice. When the width of the furnace, the airflow of the blower and the load of the house all point in the same direction, it settles the question in one go. When one of the three diverges, we tell you and steer the choice toward another model in the series.\u003c\/p\u003e\n\n\u003cp\u003eFor homeowners comparing several sizes, we gladly prepare a side-by-side table with the models in the series that fit your furnace width.\u003c\/p\u003e\n\n\u003ch3\u003eChecklist before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCoil and outdoor unit with the same refrigerant, R-32, installed together.\u003c\/li\u003e\n\u003cli\u003ePublished ratings valid for the certified match only.\u003c\/li\u003e\n\u003cli\u003eBlower and plenum compatible with 3.5 tons and 24-1\/2 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eThe complete system determines eligibility for Hydro-Québec programs. We consult the official list against the installation date and explain what applies to you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest an estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402707038500,"sku":"CAPFA4226D3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAPFA_CAPFA4226D3_00_3_5_TONNES_42000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766078","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-capfa4226d3-a-3-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}