{"product_id":"serpentin-devaporateur-goodman-capfa6030c3-a-4-tonnes","title":"GOODMAN CAPFA6030C3 Evaporator A-Coil | 4 Tons","description":"\u003ch2\u003eCAPFA6030C3: a 4-ton coil, 30 in tall, for large homes with a furnace\u003c\/h2\u003e\n\u003cp\u003eAt 4 tons (48,000 BTU\/h), you move into a different category. The \u003cstrong\u003eCAPFA6030C3\u003c\/strong\u003e is no longer a coil for the average home: it targets large multi-storey houses, sprawling single-storey homes and properties with a fully finished basement. Its cabinet measures 21 in wide, 30 in tall and 21 in deep. It runs on \u003cstrong\u003eR-32 refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is a cased A-coil from the Goodman CAPFA range, mounted on a furnace or a blower cabinet. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhat changes at 4 tons\u003c\/h3\u003e\n\u003cp\u003eA coil this size moves a lot of air. The airflow required is clearly higher than for the small sizes, and it is the furnace blower that has to deliver it. If it can't, the coil freezes or the house lacks comfort, which wastes the benefits of large equipment.\u003c\/p\u003e\n\u003cp\u003eThat is why the assessment visit matters as much as the product. We examine the blower, the plenum, the cross-section of the ducts and the return air. We confirm the size only after these checks.\u003c\/p\u003e\n\n\u003ch3\u003eA 30 in tall cabinet: what it means\u003c\/h3\u003e\n\u003cp\u003eThe 30 in height is the most visible characteristic of this model. A taller cabinet houses more heat-exchange surface, but it also needs more clearance above the furnace. In a basement with a low ceiling, we measure carefully before committing. If the clearance is insufficient, we offer solutions: changing the position of the cabinet, moving a duct or choosing another size.\u003c\/p\u003e\n\n\u003ch3\u003eWhere it sits among the nine models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eThe only 4-ton\u003c\/strong\u003e in the series: no other model shares this capacity.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e21 in width:\u003c\/strong\u003e the same as the CAPFA3626C3 (3 tons) and the CAPFA4226C3 (3.5 tons).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOne step up:\u003c\/strong\u003e the CAPFA6030D3, which offers 5 tons in a 24-1\/2 in cabinet.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOne step down:\u003c\/strong\u003e the CAPFA4226C3 or the CAPFA4226D3, at 3.5 tons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your furnace measures 21 in and the house calls for more than 3.5 tons, this is the model to look at. For 5 tons, you have to move to a wide cabinet.\u003c\/p\u003e\n\n\u003ch3\u003eDo you really need 4 tons?\u003c\/h3\u003e\n\u003cp\u003eThe question deserves to be asked frankly. A system that is too big runs in fits and starts, dries the air poorly and wears out its components faster. We prefer a serious load calculation to an impression. Sometimes it confirms 4 tons, especially in homes with large glass areas, high ceilings or several connected levels. Sometimes it recommends 3.5 tons, and we tell you so.\u003c\/p\u003e\n\n\u003ch3\u003eThe heat pump and the furnace together\u003c\/h3\u003e\n\u003cp\u003eWith a heat pump, the coil heats in winter through the existing ducts. The furnace stays in place with its blower, filters and heating elements, and takes over when the outdoor temperature drops below the threshold that we program together. It is a convenient solution for a large home: the heat pump does the bulk of the work, and the furnace covers the coldest periods.\u003c\/p\u003e\n\n\u003ch3\u003eEfficiency, ENERGY STAR, warranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil has no efficiency rating on its own; the ratings are those of the matched system, tied to an AHRI number.\u003c\/li\u003e\n\u003cli\u003eNo R-32 match with this coil is listed with ENERGY STAR (dataset w7cv-9xjt, checked on 2026-11-26); we consult AHRI for the outdoor unit.\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty, with online registration within 60 days (not required in Quebec).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCAPFA6030C3 technical features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003esize: 4 tons (48,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-32, leak sensor designed for the life of the coil;\u003c\/li\u003e\n\u003cli\u003emetering device: piston;\u003c\/li\u003e\n\u003cli\u003epositions: upflow or downflow;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid, 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003econdensate drain: 3\/4 in FNPT, primary and secondary;\u003c\/li\u003e\n\u003cli\u003edimensions: 21 × 30 × 21 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA large North Shore home, an example\u003c\/h3\u003e\n\u003cp\u003eTake a cottage on the North Shore with a finished basement, an open kitchen and a large picture window. In summer, heat builds up upstairs, and window units are no longer enough. A central system with a 4-ton coil, well matched and well tuned, spreads the cool air throughout the building using the existing ducts. What remains is to check that those ducts pass enough air; that is the point on which we spend the most time.\u003c\/p\u003e\n\n\u003ch3\u003eCommon questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs my electrical service sufficient?\u003c\/strong\u003e We check it at the visit, because the outdoor unit needs its own circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the furnace keep a role?\u003c\/strong\u003e Yes, as a backup source and as the blower.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my old air conditioner?\u003c\/strong\u003e Generally not, because of R-32.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat if my furnace is narrower?\u003c\/strong\u003e We build and insulate a transition on site.\u003c\/p\u003e\n\n\u003ch3\u003eThe role of return air in a large home\u003c\/h3\u003e\n\u003cp\u003ePeople talk a lot about supply registers, but it is often the return air that limits a large system. If air doesn't return easily enough to the furnace, the blower struggles, the coil gets too cold and comfort drops. In a multi-storey home, we check whether there is a return on each level and whether the grilles are big enough for the airflow of the CAPFA6030C3.\u003c\/p\u003e\n\u003cp\u003eA simple fix, such as an extra return or an enlarged duct, costs less than oversized equipment, and it improves the result of the whole system.\u003c\/p\u003e\n\n\u003ch3\u003eMaintaining a system of this size\u003c\/h3\u003e\n\u003cp\u003eA large coil collects dust faster if the filter is neglected. We recommend checking the filter regularly and scheduling a visit before the hot season. Checking the pan, the drain and the connections takes little time and avoids bad surprises. We give you a short guide on what to look at between visits.\u003c\/p\u003e\n\n\u003ch2\u003eThe AirGreen installation\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. For this coil, we measure the furnace, check the blower and the electrical panel, mount the cabinet, seal the duct connections, install the outdoor unit, braze the piping, pressure-test with nitrogen, pull a vacuum, connect the drain and the thermostat, then adjust the airflow and explain how it works.\u003c\/p\u003e\n\n\u003cp\u003eKeep in mind that a 4-ton coil is a significant investment: it is better to take an extra week to validate the sizing than to regret a poorly suited system. We remain reachable after the visit to answer your questions.\u003c\/p\u003e\n\n\u003ch3\u003eTo check before choosing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCoil and outdoor unit in R-32, installed together.\u003c\/li\u003e\n\u003cli\u003ePublished ratings valid for the certified match.\u003c\/li\u003e\n\u003cli\u003eBlower, plenum, 30 in height clearance and 21 in width to be confirmed during the visit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eEligibility for Hydro-Québec programs depends on the complete system, not on the coil alone. We check the official list against the installation date and tell you what applies to your project.\u003c\/p\u003e\n\n\u003ch3\u003eYour on-site estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402708218148,"sku":"CAPFA6030C3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAPFA_CAPFA6030C3_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766077","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-capfa6030c3-a-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}