{"product_id":"serpentin-devaporateur-goodman-capfa6030d3-a-5-tonnes","title":"GOODMAN CAPFA6030D3 Evaporator A-Coil | 5 Tons","description":"\u003ch2\u003eCAPFA6030D3: 5 tons, 24-1\/2 in, the largest coil in the CAPFA family\u003c\/h2\u003e\n\u003cp\u003eAt the top of the Goodman CAPFA series, the \u003cstrong\u003eCAPFA6030D3\u003c\/strong\u003e is rated at 5 tons (60,000 BTU\/h). Its cabinet measures 24-1\/2 in wide, 30 in tall and 21 in deep. It runs on \u003cstrong\u003eR-32 refrigerant\u003c\/strong\u003e, with a piston metering device, and mounts on a furnace or a blower cabinet, in upflow or downflow position.\u003c\/p\u003e\n\u003cp\u003eIt is a model for very large homes, for those that have grown through renovations, and for properties where a finished basement is added to two storeys. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eTwo checks first: electricity and air\u003c\/h3\u003e\n\u003cp\u003eAt this size, two points get settled before we talk about the model. First, the electrical service: the outdoor unit needs its own circuit, and the panel must be able to take it. Second, air distribution: the ducts, the returns and the blower must be able to deliver the airflow of a 5-ton system.\u003c\/p\u003e\n\u003cp\u003eWe assess both at the visit. If the air network is too tight, we propose corrections or, frankly, a system of two smaller zones, which might serve the home better than one big unit.\u003c\/p\u003e\n\n\u003ch3\u003eThe \"large\" model within the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 5 tons, the highest; the CAPFA6030C3 comes next with 4 tons, then the three 3.5-ton models (CAPFA4226B3, C3 and D3).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWidth:\u003c\/strong\u003e 24-1\/2 in, the same as the three other D3 models, namely the CAPFA3022D3, the CAPFA3626D3 and the CAPFA4226D3.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeight:\u003c\/strong\u003e 30 in, like the CAPFA6030C3; the only two models to reach this height are the models of the 6030 family.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CAPFA6030D3 is therefore the only coil in the series to combine the largest capacity and the largest width. If your home calls for 5 tons, there is no alternative in the range. If 4 tons is enough and your furnace is 21 in, look at the CAPFA6030C3.\u003c\/p\u003e\n\n\u003ch3\u003eWhy a coil this size isn't always the best idea\u003c\/h3\u003e\n\u003cp\u003eBigger doesn't mean better. A 5-ton unit in a home that only needs 3 or 4 tons starts and stops too often, dries the air poorly and leaves a clammy feeling. We prefer a load calculation to a rough rule, and we don't hesitate to recommend a smaller size when the numbers justify it.\u003c\/p\u003e\n\n\u003ch3\u003eThe refrigerant circuit, on the technical side\u003c\/h3\u003e\n\u003cp\u003eThe liquid arrives through the 3\/8 in connection and passes through the piston. It then evaporates in the coil tubes and returns to the outdoor unit through the 7\/8 in suction. The pan collects the condensation water and directs it to a 3\/4 in FNPT drain, with a primary and a secondary outlet. An R-32 refrigerant sensor, designed for the whole life of the coil, watches for leaks.\u003c\/p\u003e\n\n\u003ch3\u003eA heat pump for the whole year\u003c\/h3\u003e\n\u003cp\u003eConnected to a heat pump, the coil heats in winter and cools in summer. The furnace keeps its blower and filters and takes over in deep cold according to a threshold that we set with you. In a large home, this redundancy offers real peace of mind.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the published ratings are worth\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil has no efficiency rating of its own. The ratings belong to the matched system and its AHRI number, which we confirm before ordering.\u003c\/li\u003e\n\u003cli\u003eNo R-32 match with this coil is listed with ENERGY STAR (dataset w7cv-9xjt, checked on 2026-11-26).\u003c\/li\u003e\n\u003cli\u003eGoodman provides a 10-year limited parts warranty, with online registration within 60 days of installation (not required in Quebec).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCAPFA6030D3 features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003enominal size: 5 tons (60,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-32;\u003c\/li\u003e\n\u003cli\u003emetering device: piston;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid, 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003edrain: 3\/4 in FNPT, primary and secondary;\u003c\/li\u003e\n\u003cli\u003edimensions: 24-1\/2 × 30 × 21 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOver the course of a large job\u003c\/h3\u003e\n\u003cp\u003eA project of this scale always begins with a conversation. We visit the house, go upstairs, go down to the basement and talk about how you live in your home. We note where it's hot, where it's cold, where the noise is bothersome. Then we measure.\u003c\/p\u003e\n\u003cp\u003eOn installation day, the cabinet is mounted and sealed, the outdoor unit set in place, and the piping carefully brazed. The nitrogen test and the vacuum come before the system is opened, and we finish by adjusting the airflow room by room.\u003c\/p\u003e\n\n\u003ch3\u003eQuestions we get\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs it enough for the whole house?\u003c\/strong\u003e That is the job of the load calculation. \u003cstrong\u003eDo I have to change my panel?\u003c\/strong\u003e Maybe; we check. \u003cstrong\u003eIs the furnace kept?\u003c\/strong\u003e Yes, as backup. \u003cstrong\u003eWhat if my furnace's width differs?\u003c\/strong\u003e We build an insulated transition on site.\u003c\/p\u003e\n\n\u003ch3\u003eOne system or two? The question we ask\u003c\/h3\u003e\n\u003cp\u003eIn some large homes, a single 5-ton coil is not the best answer. A house stretched out lengthwise, or spread over several distinct levels, is sometimes tuned more finely with two mid-size systems, each serving its own zone. You gain in comfort, redundancy and flexibility: if one unit stops, the other keeps going.\u003c\/p\u003e\n\u003cp\u003eConversely, when the ducts are already well sized and the blower is robust, a single large system remains the simplest solution. We present both options with their advantages, then let you choose.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the CAPFA6030D3 doesn't replace\u003c\/h3\u003e\n\u003cp\u003eA large coil corrects neither poor insulation nor leaky windows. Before sizing, we look at stray air leaks, the attic and the walls. Sometimes a few insulation fixes make it possible to choose a smaller size, which lightens both the initial bill and the operating cost.\u003c\/p\u003e\n\n\u003ch2\u003eAirGreen, your heating and cooling installer in Greater Montreal\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is covered by RBQ licence 5645-9605-01. For this coil and its outdoor unit, we measure the furnace, check the blower and the electrical panel, mount the cabinet, install the outdoor unit, braze the piping, pressure-test with nitrogen, pull a vacuum, connect the drain and the thermostat and commission the system.\u003c\/p\u003e\n\n\u003cp\u003eIf you are torn between this model and a smaller size, ask us for the full load calculation: it details the heat gains room by room and makes the decision much easier to take.\u003c\/p\u003e\n\n\u003ch3\u003eTo check before choosing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 requires an outdoor unit with the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003ePublished ratings valid for the certified match.\u003c\/li\u003e\n\u003cli\u003eElectrical service, blower, ducts and clearance for a cabinet 24-1\/2 in wide and 30 in tall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec evaluates the complete system. We consult the official list at quote time, based on the installation date, and tell you what applies.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402708939044,"sku":"CAPFA6030D3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAPFA_CAPFA6030D3_00_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766078","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-capfa6030d3-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}