{"product_id":"serpentin-devaporateur-goodman-capta1818a3-a-1-5-tonnes","title":"GOODMAN CAPTA1818A3 Evaporator A-Coil | 1.5 Tons","description":"\u003ch2\u003eCAPTA1818A3: the narrowest Goodman 1.5-ton coil, sized for condo and plex furnaces\u003c\/h2\u003e\n\u003cp\u003eIn many Montreal homes, the furnace sits in a closet you have to shuffle into sideways. If that sounds like yours, the \u003cstrong\u003eGoodman CAPTA1818A3 evaporator coil\u003c\/strong\u003e deserves a look: at 14 in wide, it is made to sit on a compact furnace without a lot of carpentry. It is a cased A-coil rated at 1.5 tons (18,000 BTU\/h) and runs on R-32 refrigerant.\u003c\/p\u003e\n\u003cp\u003eWe install it for customers in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. This page explains what it is for, how it compares with the other models in the CAPTA line, and what we check at your home before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eWhat this coil does day to day\u003c\/h3\u003e\n\u003cp\u003eThe coil is the part that exchanges heat with the air in your home. The outdoor unit sends it refrigerant, and the furnace air passes through its fins. In summer, the air comes out cooler and drier. With a heat pump, the cycle reverses in winter and the same part helps heat the house.\u003c\/p\u003e\n\u003cp\u003eYou never see it, but you feel the result: the air from the vents is cooler in July, and the water collected in the pan is carried off by the drain instead of staying in the room.\u003c\/p\u003e\n\n\u003ch3\u003eWhy 14 in of width changes the conversation\u003c\/h3\u003e\n\u003cp\u003eChoosing a coil often starts with a tape measure. A cabinet that is too wide will not fit on a narrow furnace without a transition. The CAPTA1818A3 measures 14 × 18 × 21 in (W × H × D), which is the base size of the series for this 1.5-ton rating. If your furnace width matches, installation is straightforward.\u003c\/p\u003e\n\u003cp\u003eIf it does not, we measure and, if needed, build an insulated transition on site. It is not a big deal, but it adds labour time, and it is better to know before the quote than on installation day.\u003c\/p\u003e\n\n\u003ch3\u003eA 1.5-ton size: for what kind of home?\u003c\/h3\u003e\n\u003cp\u003eThis size suits small, well-insulated spaces: a condo with a furnace, a plex unit with its own forced-air system, a small townhouse. In a space like that, a big capacity does more harm than good. An oversized system shuts off before it has dried the air, and you end up with a room that is cool but clammy.\u003c\/p\u003e\n\u003cp\u003eSo we do not pick the capacity at random. We start by estimating the home's needs, then propose the size that comes closest. If the calculation points to a larger model, we will tell you plainly.\u003c\/p\u003e\n\n\u003ch3\u003eHow the pieces go together\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulated cabinet sits on top of the furnace or blower cabinet.\u003c\/li\u003e\n\u003cli\u003eThe liquid line connection is 3\/8 in, and the suction connection is 3\/4 in.\u003c\/li\u003e\n\u003cli\u003eThe copper piping is brazed, then pressure-tested with nitrogen before evacuation.\u003c\/li\u003e\n\u003cli\u003eThe metering device is a TXV, installed to regulate refrigerant flow.\u003c\/li\u003e\n\u003cli\u003eThe coil works in upflow and downflow positions, depending on your furnace orientation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA leak sensor designed for R-32\u003c\/h3\u003e\n\u003cp\u003eR-32 is a newer-generation refrigerant. This coil includes an R-32 refrigerant sensor designed to last the life of the coil, according to the manufacturer's SS-DCoil-R32 sheet. That is part of what sets this generation of coils apart from older models: you are not just choosing a capacity, you are choosing a set of parts that accounts for the refrigerant in use.\u003c\/p\u003e\n\n\u003ch3\u003eHeating with a heat pump while keeping your furnace\u003c\/h3\u003e\n\u003cp\u003eThe most common scenario is a homeowner who heats with an electric furnace and wants to cut the bill. We add an outdoor heat pump and this coil: the furnace keeps its blower, its filters and its ductwork. It stays available as backup heat when the outdoor temperature drops below the threshold we set with you.\u003c\/p\u003e\n\u003cp\u003eHomeowners mostly appreciate two things: nothing gets demolished, and no new ducts go into the walls. The air travels through the same network as before.\u003c\/p\u003e\n\n\u003ch3\u003eCAPTA1818A3 or a neighbouring model? The comparison guide\u003c\/h3\u003e\n\u003cp\u003eGoodman's CAPTA series has eight models. They all share R-32 refrigerant, the TXV and the cabinet. What changes is the capacity and the width. Here is how to find your way.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCAPTA1818A3 (this one)\u003c\/strong\u003e: 1.5 tons, 14 in. The smallest size, in the narrowest width.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAPTA1818B3\u003c\/strong\u003e: also 1.5 tons, but in 17-1\/2 in. The one to choose if your furnace is wider.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAPTA2422A3\u003c\/strong\u003e: 1.5 to 2 tons in 14 in. Same width as this one, but for a home that needs a little more capacity.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAPTA2422B3\u003c\/strong\u003e and \u003cstrong\u003eCAPTA2422C3\u003c\/strong\u003e: 1.5 to 2 tons in 17-1\/2 in and in 21 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAPTA3022A3\u003c\/strong\u003e, \u003cstrong\u003eCAPTA3022B3\u003c\/strong\u003e and \u003cstrong\u003eCAPTA3022C3\u003c\/strong\u003e: 2 to 2.5 tons, in widths of 14 in, 17-1\/2 in and 21 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTo sum up: pick the capacity first based on the house, then the width based on the furnace. If your furnace is 14 in wide and 1.5 tons is enough, the CAPTA1818A3 is the natural choice.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to know about efficiency ratings\u003c\/h3\u003e\n\u003cp\u003eA coil on its own has no efficiency rating. Published ratings belong to the matched system, meaning the coil and outdoor unit combination identified by an AHRI number. Before ordering, we confirm that number and check that the advertised ratings are the ones for your matched system. If a competing quote promises ratings without naming the AHRI number, ask for it.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer's warranty\u003c\/h3\u003e\n\u003cp\u003eGoodman offers a 10-year limited parts warranty. Online registration within 60 days of installation is not required in Quebec, according to sheet SS-GCoil-R32. This warranty covers parts; for everything involving labour and installation, AirGreen stands behind its own work.\u003c\/p\u003e\n\n\u003ch3\u003eOur installation in Greater Montreal\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. For this coil, a typical visit includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace and checking the blower;\u003c\/li\u003e\n\u003cli\u003ea look at the electrical panel for the outdoor unit's power supply;\u003c\/li\u003e\n\u003cli\u003esetting the cabinet and sealing the duct connections;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit, brazing the piping, the nitrogen test and the evacuation;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning and a clear explanation of how it works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eBefore ordering: four checks\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 pairs only with an outdoor unit using the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe 14 in width has to match your furnace, or we plan for a transition.\u003c\/li\u003e\n\u003cli\u003eThe blower has to deliver the airflow the system requires.\u003c\/li\u003e\n\u003cli\u003eRatings apply to the certified matched system, not to the coil taken on its own.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eEligibility for Hydro-Québec programs depends on the complete system, not on the coil alone. We confirm the match against the official list based on the installation date, and we tell you clearly what applies to your project.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402705695012,"sku":"CAPTA1818A3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAPTA_CAPTA1818A3_00_1_5_TONNES_18000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766078","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-capta1818a3-a-1-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}