{"product_id":"serpentin-devaporateur-goodman-capta2422b3-a-1-5-a-2-tonnes","title":"GOODMAN CAPTA2422B3 Evaporator A-Coil | 1.5 to 2 Tons","description":"\u003ch2\u003eCAPTA2422B3: an installation day with the Goodman 1.5 to 2 ton coil in 17-1\/2 in\u003c\/h2\u003e\n\u003cp\u003eRather than drawing up a list of features, let's follow the \u003cstrong\u003eGoodman CAPTA2422B3 evaporator coil\u003c\/strong\u003e through a typical installation day. It is a good way to understand what it is, where it goes and what it asks of your home. This 1.5 to 2 ton model (24,000 BTU\/h) fits in a cabinet 17-1\/2 in wide and runs on R-32.\u003c\/p\u003e\n\u003cp\u003eIt is meant for homeowners in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e whose furnace is an intermediate width.\u003c\/p\u003e\n\n\u003ch3\u003eBefore the job: the measuring visit\u003c\/h3\u003e\n\u003cp\u003eIt all starts a few days earlier. We open the furnace casing, measure the plenum and look at the condition of the electrical panel. The CAPTA2422B3 measures 17-1\/2 × 22 × 21 in (W × H × D): we check that these dimensions fit where planned, that the height is available and that the blower can deliver the system's airflow.\u003c\/p\u003e\n\u003cp\u003eIf the furnace width does not match exactly, we plan an insulated transition built on site. No surprises on installation day.\u003c\/p\u003e\n\n\u003ch3\u003eEarly morning: the outdoor unit\u003c\/h3\u003e\n\u003cp\u003eThe first step happens outside. The outdoor unit is installed on a pad or bracket, in a clear spot. It is chosen to match this coil: same refrigerant (R-32) and a neighbouring capacity. The two parts form a matched system identified by an AHRI number that we confirmed before the order.\u003c\/p\u003e\n\n\u003ch3\u003eMidday: the coil in the plenum\u003c\/h3\u003e\n\u003cp\u003eInside, the insulated cabinet is set on the furnace. It works in upflow or downflow positions, depending on the orientation of the unit. Its liquid line connection is 3\/8 in and its suction connection is 3\/4 in. The copper piping is brazed between the outdoor unit and the coil, then tested with nitrogen to confirm it is leak-tight.\u003c\/p\u003e\n\u003cp\u003eThe metering device is a TXV. It meters refrigerant according to demand; you will never have to touch it.\u003c\/p\u003e\n\n\u003ch3\u003eLate afternoon: vacuum, drain and thermostat\u003c\/h3\u003e\n\u003cp\u003eOnce the circuit is sealed, we pull a vacuum, connect the condensate drain and wire the thermostat. The R-32 refrigerant sensor, designed to last the life of the coil (sheet SS-DCoil-R32), is already built in. We then start the system and adjust the airflow.\u003c\/p\u003e\n\n\u003ch3\u003eWhat this capacity size serves best\u003c\/h3\u003e\n\u003cp\u003eThe 1.5 to 2 ton range suits townhouses, bungalows and plex units that have their own forced-air system. It is large enough to get through a humid summer without the unit running at full capacity, and modest enough to avoid the short cycles of an oversized system.\u003c\/p\u003e\n\n\u003ch3\u003ePlacing it in the series: CAPTA2422B3 compared with its neighbours\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSame capacity, narrower\u003c\/strong\u003e: the CAPTA2422A3 is 14 in wide.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSame capacity, wider\u003c\/strong\u003e: the CAPTA2422C3 goes to 21 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSame width, less capacity\u003c\/strong\u003e: the CAPTA1818B3 offers 1.5 tons in 17-1\/2 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSame width, more capacity\u003c\/strong\u003e: the CAPTA3022B3 goes up to 2 to 2.5 tons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe logic is that of a two-way table: capacity in one direction, width in the other. This model sits in the middle square for both.\u003c\/p\u003e\n\n\u003ch3\u003eAir conditioning in summer, heating in winter\u003c\/h3\u003e\n\u003cp\u003ePaired with a heat pump, this coil lets you heat in winter through the existing ducts. The furnace becomes the backup heat in extreme cold, at a threshold we set with you. In summer, the coil cools the air and collects humidity in the condensate pan.\u003c\/p\u003e\n\u003cp\u003eIf you are replacing an old central air conditioner, the good news is that the duct network gets used again. Nothing to drill through the walls.\u003c\/p\u003e\n\n\u003ch3\u003eThat same evening: what changes in the house\u003c\/h3\u003e\n\u003cp\u003eWhen the system starts up, the first sign is the quality of the air at the vents: cooler, drier and distributed more evenly. The noise of the outdoor unit stays outside, and the furnace blower does the rest of the work indoors. We walk you through the thermostat and answer your questions about the filter and the drain.\u003c\/p\u003e\n\u003cp\u003eThe next day, you will probably not have to think about it anymore. That is the goal: equipment that fades into the background behind the comfort it provides.\u003c\/p\u003e\n\n\u003ch3\u003eA concrete example: the South Shore bungalow\u003c\/h3\u003e\n\u003cp\u003ePicture a bungalow whose basement is used mostly for storage and whose furnace is a mid-range width. The owner wants air conditioning without running new ducts, and wants to cut what the electric furnace costs in winter. A mid-width cabinet and a 1.5 to 2 ton capacity fit that profile without excess. That is typically where the CAPTA2422B3 fits.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we do not promise\u003c\/h3\u003e\n\u003cp\u003eWe do not quote you a percentage of savings before we have seen your home. The real gain depends on insulation, air tightness, the current heating system and the matched system chosen. What we give you is a written quote, a verified AHRI number and a clean installation.\u003c\/p\u003e\n\n\u003ch3\u003eWhy install everything at the same time\u003c\/h3\u003e\n\u003cp\u003eAn R-32 coil does not accept just any outdoor unit: the two parts must share the same refrigerant and form a recognized matched system. That is why we install both on the same day, with a single set of new piping. That way you avoid paying for labour twice and you end up with a system in which every component has been verified, from the nitrogen leak test to the airflow adjustment.\u003c\/p\u003e\n\u003cp\u003eIf a contractor offers to replace only the outdoor unit, ask about the refrigerant and the AHRI number. The answer says a lot about the quality of the quote.\u003c\/p\u003e\n\n\u003ch3\u003eEfficiency: what a coil says (and does not say)\u003c\/h3\u003e\n\u003cp\u003eThe coil has no efficiency rating of its own; the figures displayed belong to the certified set. That is why we never give you a rating without the AHRI number that backs it. If you are comparing quotes, ask each contractor to provide it.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer's warranty\u003c\/h3\u003e\n\u003cp\u003eGoodman's 10-year limited warranty covers parts. Online registration within 60 days of installation is not required in Quebec (Goodman sheet SS-GCoil-R32).\u003c\/p\u003e\n\n\u003ch3\u003eWho works at your home\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. You know who you are talking to from start to finish of the project.\u003c\/p\u003e\n\n\u003ch3\u003ePoints to confirm before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 requires an outdoor unit with the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe 17-1\/2 in cabinet has to suit your furnace, with a transition if needed.\u003c\/li\u003e\n\u003cli\u003eThe blower has to deliver the required airflow.\u003c\/li\u003e\n\u003cli\u003ePublished ratings are tied to the certified system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs assess the complete system, not the coil alone. We check the official list based on the installation date and spell out what applies to your file.\u003c\/p\u003e\n\n\u003ch3\u003eTake the next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402707661092,"sku":"CAPTA2422B3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAPTA_CAPTA2422B3_00_1_5_A_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766078","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-capta2422b3-a-1-5-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}