{"product_id":"serpentin-devaporateur-goodman-capta4230d3-a-2-5-a-3-5-tonnes","title":"GOODMAN CAPTA4230D3 Evaporator A-Coil | 2.5 to 3.5 Tons","description":"\u003ch2\u003eCAPTA4230D3: a 24-1\/2 in cabinet for the 2.5 to 3.5 ton size\u003c\/h2\u003e\n\u003cp\u003eLarge furnaces have wide cabinets. When you fit a coil narrower than the plenum, you end up improvising sheet metal and joints, and the air finds the leaks. The \u003cstrong\u003eGoodman CAPTA4230D3\u003c\/strong\u003e solves this situation: it is a cased A-shaped evaporator coil, rated 2.5 to 3.5 tons (42,000 BTU\/h), using R-32 refrigerant, with a width of 24-1\/2 in.\u003c\/p\u003e\n\u003cp\u003eThe page that follows describes its role, its installation and how it differs from the other CAPTA models. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eThe D3 compared with the C3: width only\u003c\/h3\u003e\n\u003cp\u003eThe CAPTA4230C3 and the CAPTA4230D3 offer the same nominal capacity, the same TXV, the same refrigerant and the same connections. They differ in width: 21 in for the first, 24-1\/2 in for the second. The rest of the decision comes down to your furnace's cabinet.\u003c\/p\u003e\n\u003cp\u003eThat is why we start with the tape measure. A cabinet of the right size means air that passes well through the coil and does not escape at the sides.\u003c\/p\u003e\n\n\u003ch3\u003eA wide furnace, a generous plenum\u003c\/h3\u003e\n\u003cp\u003eThis size is meant for cottages and large single-storey homes whose ducts serve many rooms. The coil has more exchange surface than the smaller sizes, and the system requires more airflow, which the blower must provide.\u003c\/p\u003e\n\u003cp\u003eDuring the assessment, we check the blower's capacity, the size of the plenum and the condition of the return ducts before confirming the size. If something is off, we propose a fix and put it in the quote.\u003c\/p\u003e\n\n\u003ch3\u003eCAPTA4230D3 model sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emanufacturer: Goodman, CAPTA series;\u003c\/li\u003e\n\u003cli\u003etype: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003enominal size: 2.5 to 3.5 tons (42,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-32 with TXV metering device;\u003c\/li\u003e\n\u003cli\u003edimensions (W × H × D): 24-1\/2 × 30 × 21 in;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in for the liquid, 7\/8 in for the suction;\u003c\/li\u003e\n\u003cli\u003epossible positions: upflow or downflow;\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant sensor designed for the life of the coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhere it sits in the series\u003c\/h3\u003e\n\u003cp\u003eIn the CAPTA series, 24-1\/2 in cabinets exist only in the two largest sizes. In plain terms:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003efor a 24-1\/2 in furnace with a load of 2.5 to 3.5 tons, this is the CAPTA4230D3;\u003c\/li\u003e\n\u003cli\u003efor a 24-1\/2 in furnace with a load of 3.5 to 5 tons, it is the CAPTA6030D3;\u003c\/li\u003e\n\u003cli\u003efor a narrower 21 in furnace, the CAPTA4230C3 and CAPTA6030C3 take over;\u003c\/li\u003e\n\u003cli\u003efor smaller loads, the CAPTA3026B3, CAPTA3026C3, CAPTA3626B3 and CAPTA3626C3.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe path of the air and the heat\u003c\/h3\u003e\n\u003cp\u003eThe blower sends the house air upward, to the centre of the A, which spreads it across its two sloped faces. The refrigerant, on the other side of the tubes, changes state and absorbs heat in summer. The condensation falls into the pan and goes to the drain. In heating mode with a heat pump, the refrigerant instead delivers the heat picked up outside by the outdoor unit.\u003c\/p\u003e\n\n\u003ch3\u003eWhy the furnace stays useful\u003c\/h3\u003e\n\u003cp\u003eAn electric furnace creates an amount of heat equal to the electricity it consumes. A heat pump moves heat, and supplies two to three times more thermal energy than the electricity consumed in mild weather. When it is really cold, this ratio drops: the furnace then takes over, according to a threshold that we set together. You therefore keep a backup system without paying for a second heating appliance.\u003c\/p\u003e\n\n\u003ch3\u003eSEER2, EER2, HSPF2: what to rely on\u003c\/h3\u003e\n\u003cp\u003eEfficiency ratings are not read off the coil, but off the certified system, linked by an AHRI number. This number lets you compare two quotes on an equal footing and is used by incentive programs.\u003c\/p\u003e\n\u003cp\u003eThe CAPTA4230D3 is paired with a Goodman outdoor unit of the same capacity and the same refrigerant. At our last check, no R-32 match with this coil was listed in ENERGY STAR; we therefore go through the AHRI directory for the unit selected.\u003c\/p\u003e\n\n\u003ch3\u003eOur installation method\u003c\/h3\u003e\n\u003cp\u003eA family-owned heating and cooling company based in Montreal for more than fifteen years, AirGreen works under RBQ licence 5645-9605-01. Every job includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, with a transition built if needed, and sealing the ducts;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit on a pad or bracket, brazed piping, the nitrogen test and the vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and handing over the usage instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhen a transition beats changing the model\u003c\/h3\u003e\n\u003cp\u003eSometimes a furnace is barely narrower or wider than the chosen cabinet. Rather than multiply part numbers, we build an insulated sheet-metal transition, carefully sealed, that connects the plenum to the cabinet. This is common practice on the job, and it keeps the benefit of the cabinet supplied with the coil.\u003c\/p\u003e\n\u003cp\u003eThe transition should remain an exception, though. If the gap is large, it is better to choose the model whose width is closest: less sheet metal, fewer joints, less risk of air leakage.\u003c\/p\u003e\n\n\u003ch3\u003eThink about the shoulder seasons\u003c\/h3\u003e\n\u003cp\u003eIn fall and spring, when temperatures stay mild, the heat pump does most of the work in a home of this size. These are the times when the furnace runs the least and the difference shows on the electricity bill. In summer, the same coil cools the whole house through the existing ducts, without window units.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently asked questions, short answers\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan my old air conditioner stay?\u003c\/strong\u003e Generally not: the coil runs on R-32, and the outdoor unit must be the one specified by the manufacturer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy cabinet is narrower than 24-1\/2 in.\u003c\/strong\u003e Move to the CAPTA4230C3 or let us build an insulated transition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it only cool?\u003c\/strong\u003e Yes, with a central air conditioner. It also heats when paired with a heat pump.\u003c\/p\u003e\n\n\u003ch3\u003eTo confirm before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe outdoor unit must be R-32 and installed at the same time as the coil.\u003c\/li\u003e\n\u003cli\u003eThe published ratings belong to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe furnace must have the width and a blower with the required airflow; we confirm this at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eGoodman, the brand and the warranty\u003c\/h3\u003e\n\u003cp\u003eGoodman is one of the brands of Daikin Comfort Technologies, along with Daikin and Amana. Its 10-year limited warranty covers parts; online registration within 60 days after installation is not required in Quebec.\u003c\/p\u003e\n\n\u003ch3\u003eHydro-Québec programs\u003c\/h3\u003e\n\u003cp\u003eEligibility is judged on the matched system and the installation date, not on the coil alone. We consult the official list when we prepare the quote.\u003c\/p\u003e\n\n\u003ch3\u003ePlan the visit\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402718408996,"sku":"CAPTA4230D3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAPTA_CAPTA4230D3_00_2_5_A_3_5_TONNES_42000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766078","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-capta4230d3-a-2-5-a-3-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}