{"product_id":"serpentin-devaporateur-goodman-capta6030c3-a-3-5-a-5-tonnes","title":"GOODMAN CAPTA6030C3 Evaporator A-Coil | 3.5 to 5 Tons","description":"\u003ch2\u003eCAPTA6030C3: a 3.5 to 5 ton Goodman coil for the large home, above all a matter of electrical circuit and ducts\u003c\/h2\u003e\n\u003cp\u003eIn a large home, the coil is never the only topic of discussion. Goodman's \u003cstrong\u003eCAPTA6030C3\u003c\/strong\u003e is an A-shaped evaporator coil, with a 21 × 30 × 21 in cabinet, rated 3.5 to 5 tons (60,000 BTU\/h), using R-32 refrigerant. It is aimed at large properties in Montreal, Laval, Longueuil, the North Shore and the South Shore. At this scale, it is the electrical service and the air distribution that make a project succeed.\u003c\/p\u003e\n\n\u003ch3\u003eWho needs 3.5 to 5 tons?\u003c\/h3\u003e\n\u003cp\u003eThis size is meant for large homes, properties with a finished basement and homes enlarged over the years. An added kitchen, an extra floor, an enclosed sunroom: each addition brings needs that the original furnace did not anticipate.\u003c\/p\u003e\n\u003cp\u003eWe tell you frankly when two smaller systems would serve the home better. In a house with several wings, two furnaces and two coils can spread comfort better than a single big unit that struggles to reach the far rooms.\u003c\/p\u003e\n\n\u003ch3\u003eFirst point to check: the electrical service\u003c\/h3\u003e\n\u003cp\u003eThe outdoor unit that goes with this coil requires a dedicated circuit. In an older home whose panel has few free breakers, the panel sometimes has to be reviewed before talking about a heat pump. Our electrical work is done under our own RBQ licence 5645-9605-01: we assess the panel during the visit and include it in the quote, with no subcontractor to coordinate.\u003c\/p\u003e\n\n\u003ch3\u003eSecond point: air distribution\u003c\/h3\u003e\n\u003cp\u003eThe system reaches its full performance only if the airflow of the duct network is sufficient. We examine the blower, the size of the plenum and the diameter of the return ducts. An undersized network, inherited from a time when the house was smaller, will not let through the air that a coil of this capacity demands.\u003c\/p\u003e\n\u003cp\u003eThis is a subject to raise at the very first visit, because correcting the ducts costs less before installation than after.\u003c\/p\u003e\n\n\u003ch3\u003e21 in or 24-1\/2 in?\u003c\/h3\u003e\n\u003cp\u003eThe CAPTA6030C3 is installed on furnaces 21 in wide. For a 24-1\/2 in cabinet, the same capacity exists in the CAPTA6030D3. Between them, there is no difference in capacity or refrigerant: only the width changes. If you hesitate between these two models, measuring the cabinet, rather than the catalogue, will make the difference.\u003c\/p\u003e\n\u003cp\u003eIf the load calculation reveals a more modest need, the CAPTA4230C3, at 2.5 to 3.5 tons, shares the 21 in width.\u003c\/p\u003e\n\n\u003ch3\u003eOne big system or two smaller ones?\u003c\/h3\u003e\n\u003cp\u003eA single system is simpler to maintain: one outdoor unit, one thermostat, one coil to watch. In return, everything depends on a duct network able to distribute air everywhere. Two systems cost more in equipment but offer two independent zones, which helps when the upper floor and the basement do not have the same needs.\u003c\/p\u003e\n\u003cp\u003eWe present both options on paper, with the advantages of each, before you decide. No pressure: the right choice is the one that suits your home and the way you live in it.\u003c\/p\u003e\n\n\u003ch3\u003eThe finished basement, a special case\u003c\/h3\u003e\n\u003cp\u003eA finished basement adds rooms to cool, but it stays naturally cooler than the upper floors. In that case, a good part of the cooling load is concentrated upstairs. We take this into account in the calculation, because it would be a shame to pay for capacity that is lost in rooms that are already cool.\u003c\/p\u003e\n\n\u003ch3\u003eCAPTA6030C3 dimensions and connections\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ebrand and series: Goodman CAPTA;\u003c\/li\u003e\n\u003cli\u003enominal size: 3.5 to 5 tons (60,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-32; metering device: TXV;\u003c\/li\u003e\n\u003cli\u003edimensions (W × H × D): 21 × 30 × 21 in;\u003c\/li\u003e\n\u003cli\u003eliquid connection: 3\/8 in; suction connection: 7\/8 in;\u003c\/li\u003e\n\u003cli\u003epositions: upflow or downflow;\u003c\/li\u003e\n\u003cli\u003einsulated cabinet supplied; R-32 refrigerant sensor designed for the life of the coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat the coil accomplishes\u003c\/h3\u003e\n\u003cp\u003eIn the path of the air, in the plenum, the coil receives liquid refrigerant, which evaporates in its tubes in summer and cools the air. The condensed moisture is collected in the pan and removed through the drain. With a heat pump, the cycle reverses in winter and the coil becomes the exchanger that heats the air in the ducts.\u003c\/p\u003e\n\u003cp\u003eThe furnace keeps its blower, its filters and its heating elements. In a large home where winter nights can be harsh, this backup is valuable: it steps in below the temperature threshold that we set with you.\u003c\/p\u003e\n\n\u003ch3\u003eHow efficient? Ask for the AHRI number\u003c\/h3\u003e\n\u003cp\u003eThe coil carries no efficiency rating: SEER2, EER2 and HSPF2 relate to the matched system, identified by an AHRI number. For a large home, the difference between two systems adds up in kilowatt-hours over the whole season, and the number lets you compare.\u003c\/p\u003e\n\u003cp\u003eThe CAPTA6030C3 is matched with a Goodman outdoor unit of the same capacity and the same refrigerant. At our last check, no R-32 match of this coil was listed in ENERGY STAR; we rely on AHRI.\u003c\/p\u003e\n\n\u003ch3\u003eHow a job of this size unfolds\u003c\/h3\u003e\n\u003cp\u003eAirGreen, a family-owned heating and cooling company based in Montreal for more than fifteen years, plans this kind of project in stages:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower, the electrical panel and the ducts;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, a transition built if needed, sealing the connections;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed piping, nitrogen leak test, vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment, explanations to the homeowner.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTo confirm before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe outdoor unit must use R-32 and be installed at the same time as the coil.\u003c\/li\u003e\n\u003cli\u003eThe advertised ratings apply to the certified match, not to the coil alone.\u003c\/li\u003e\n\u003cli\u003eThe furnace must be the right size and have a blower that delivers the required airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe brand and its warranty\u003c\/h3\u003e\n\u003cp\u003eGoodman is part of Daikin Comfort Technologies, like Daikin and Amana. The 10-year limited warranty covers parts; online registration within 60 days after installation is not required in Quebec.\u003c\/p\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs assess the complete system according to the installation date, not the coil taken alone. We check the official list when we prepare the quote and tell you what applies.\u003c\/p\u003e\n\n\u003ch3\u003eGet your quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402719129892,"sku":"CAPTA6030C3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAPTA_CAPTA6030C3_00_3_5_A_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766078","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-capta6030c3-a-3-5-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}