{"product_id":"serpentin-devaporateur-goodman-cauta3022a3-a-2-a-2-5-tonnes","title":"GOODMAN CAUTA3022A3 Evaporator A-Coil | 2 to 2.5 Tons","description":"\u003ch2\u003eCAUTA3022A3: replace an old central air conditioner with a 13 in Goodman coil of 2 to 2.5 tons\u003c\/h2\u003e\n\u003cp\u003eIs your central air conditioner many years old, running on the refrigerant of another era, and are you thinking of replacing it? The \u003cstrong\u003eGoodman CAUTA3022A3\u003c\/strong\u003e is an uncased A-shaped evaporator coil running on \u003cstrong\u003eR-32\u003c\/strong\u003e, whose nominal size of 30,000 BTU\/h corresponds to 2 to 2.5 tons. Its 13 in width suits furnaces with a narrow outlet.\u003c\/p\u003e\n\u003cp\u003eIt is installed by our crews in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, often during complete replacements.\u003c\/p\u003e\n\n\u003ch3\u003eThe real subject: a new system, not an isolated part\u003c\/h3\u003e\n\u003cp\u003eThe coil of an old air conditioner and its outdoor unit form a pair. When one of the two gives out, it is rarely wise to change only the other. R-32 also requires pairing the coil with an outdoor unit using the same fluid. That is why we always propose replacing the complete system, in a single visit.\u003c\/p\u003e\n\u003cp\u003eThe CAUTA3022A3 is the indoor half of this pair. It goes in the furnace plenum, while the Goodman outdoor unit of the same capacity sits outside, on a stand.\u003c\/p\u003e\n\n\u003ch3\u003eA 2 to 2.5 ton size: who is it for?\u003c\/h3\u003e\n\u003cp\u003eThis size suits homes more spacious than those in the 1.5 to 2 ton size: two-storey cottages, large bungalows, semi-detached homes with several bedrooms. In these cases, the cooling load is larger and a more generous coil is called for.\u003c\/p\u003e\n\u003cp\u003eWe do not pick the biggest just in case, though. A load calculation is based on the walls, windows, exposure and ventilation of your home. If the result falls below the size, we propose a smaller model from the series, because an oversized unit shuts off too soon and leaves the air damp.\u003c\/p\u003e\n\n\u003ch3\u003eThirteen inches: an asset in cramped mechanical rooms\u003c\/h3\u003e\n\u003cp\u003eIt is fairly common for a good-sized home to have a furnace with a narrow outlet. This happens when the furnace was chosen for its small footprint rather than its capacity. For these cases, the 13 in of this coil avoids building a transition and simplifies the installation.\u003c\/p\u003e\n\u003cp\u003eIf your furnace is wider, two other versions of the same capacity exist: the CAUTA3022B3 in 16-1\/2 in and the CAUTA3022C3 in 20 in. We measure before deciding.\u003c\/p\u003e\n\n\u003ch3\u003eWhat happens in the plenum\u003c\/h3\u003e\n\u003cp\u003eTwo sloped faces form the A. The furnace air passes through them, the refrigerant evaporates in the tubes under the control of a TXV metering device, and the heat of the air is absorbed. The moisture that condenses is collected in the pan, then removed through the drain.\u003c\/p\u003e\n\u003cp\u003eUncased, the coil is installed in the existing plenum or in a casing made to the measurements of the space. It can be set in upflow or downflow position.\u003c\/p\u003e\n\n\u003ch3\u003eAnd heating? The coil plays a part there too\u003c\/h3\u003e\n\u003cp\u003eIf you pair it with a heat pump rather than a simple air conditioner, the same coil serves to heat in winter. The furnace then stays in place as backup heat. You can therefore use the replacement of your air conditioner to move to a two-season solution, without redoing the ducts.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing within the CAUTA series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e: 1.5 tons (CAUTA1818A3 and B3), 1.5 to 2 tons (CAUTA2422A3, B3, C3) or 2 to 2.5 tons (CAUTA3022A3, B3, C3: the family of this page);\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e: 13 in (A3), 16-1\/2 in (B3) or 20 in (C3);\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEverything else is common\u003c\/strong\u003e: R-32, TXV metering device, uncased.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CAUTA3022A3 is therefore the smallest width of the largest capacity in the series.\u003c\/p\u003e\n\n\u003ch3\u003eEfficiency: what the coil does not tell you on its own\u003c\/h3\u003e\n\u003cp\u003eThe SEER2, EER2 and HSPF2 ratings are not attached to the coil. They characterize a certified match-up, identified by an AHRI number, and that number is what we confirm before ordering. When comparing two offers, it is to this number that you should turn.\u003c\/p\u003e\n\u003cp\u003eThe ENERGY STAR list, when we last consulted it, contained no R-32 match-up with this coil. AHRI remains the reference for the outdoor unit chosen.\u003c\/p\u003e\n\n\u003ch3\u003eSigns that a replacement should be considered\u003c\/h3\u003e\n\u003cp\u003eAn air conditioner that is running out of breath gives clues: the air from the registers is less cold, the unit runs nonstop on hot days, the house stays damp, the electricity bill climbs. It also happens that the indoor coil is clogged or that the condensate pan lets water through. When several of these signs pile up, it is a good time to compare a new system with one more repair.\u003c\/p\u003e\n\u003cp\u003eDuring the visit, we examine the old coil, note its condition and show it to you if needed. That way, the decision rests on what you see with your own eyes.\u003c\/p\u003e\n\u003ch3\u003eThe manufacturer\u003c\/h3\u003e\n\u003cp\u003eGoodman is a brand of Daikin Comfort Technologies, which also includes the Daikin and Amana brands. Its R-32 coils are made for new-generation heat pumps and central air conditioners, on a furnace or on a modular blower.\u003c\/p\u003e\n\u003ch3\u003eCAUTA3022A3 characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003euncased evaporator coil of the CAUTA line;\u003c\/li\u003e\n\u003cli\u003enominal size 2 to 2.5 tons (30,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant, leak sensor designed for the life of the coil;\u003c\/li\u003e\n\u003cli\u003ewidth of 13 in;\u003c\/li\u003e\n\u003cli\u003eliquid 3\/8 in, suction 3\/4 in;\u003c\/li\u003e\n\u003cli\u003eTXV metering device;\u003c\/li\u003e\n\u003cli\u003eupflow or downflow installation;\u003c\/li\u003e\n\u003cli\u003e10-year limited warranty on parts, with online registration within 60 days not required in Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow a replacement goes at AirGreen\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. For a replacement, we:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasure the furnace and check the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003eremove the old coil and install the new one, with leak-tight joints;\u003c\/li\u003e\n\u003cli\u003eset the outdoor unit, braze the piping, test with nitrogen and pull a vacuum;\u003c\/li\u003e\n\u003cli\u003ereconnect the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003estart everything up, adjust the airflow and explain how it works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTo check before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe width of the furnace outlet: 13 in for this model.\u003c\/li\u003e\n\u003cli\u003eThe airflow the blower can actually deliver.\u003c\/li\u003e\n\u003cli\u003eThe refrigerant of the outdoor unit: R-32, like the coil.\u003c\/li\u003e\n\u003cli\u003eThe AHRI number of the match-up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAfter the installation: what we leave you with\u003c\/h3\u003e\n\u003cp\u003eAt the end of the job, we explain the thermostat, the location of the drain and how often to change the filter. We also leave you a written summary of the airflow settings chosen, so that you can show it to another technician if the need ever arises.\u003c\/p\u003e\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec assesses the complete system and not the isolated coil for its programs. We consult the official list at the time of the quote, according to the installation date, and present clearly what applies to your case.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402720702756,"sku":"CAUTA3022A3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAUTA_CAUTA3022A3_00_2_A_2_5_TONNES_30000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766080","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-cauta3022a3-a-2-a-2-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}