{"product_id":"serpentin-devaporateur-goodman-cauta3022b3-a-2-a-2-5-tonnes","title":"GOODMAN CAUTA3022B3 Evaporator A-Coil | 2 to 2.5 Tons","description":"\u003ch2\u003eCAUTA3022B3: a Quebec winter with a 2 to 2.5 ton, 16-1\/2 in Goodman coil on your furnace\u003c\/h2\u003e\n\u003cp\u003eIn Quebec, a heat pump is judged in January. The \u003cstrong\u003eGoodman CAUTA3022B3\u003c\/strong\u003e is the indoor coil that lets a central heat pump connect to the air system of an existing furnace. It is A-shaped, uncased, runs on \u003cstrong\u003eR-32\u003c\/strong\u003e, with a nominal size of 30,000 BTU\/h that corresponds to 2 to 2.5 tons, and a width of 16-1\/2 in.\u003c\/p\u003e\n\u003cp\u003eWe install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, in homes where people want to rely less on electric heating without giving up the furnace.\u003c\/p\u003e\n\n\u003ch3\u003eThe role of the coil when it is cold\u003c\/h3\u003e\n\u003cp\u003eIn summer, the coil acts as the evaporator: it removes heat from the air of the house. In winter, with a heat pump, the cycle reverses. The outdoor unit captures heat from the outside air, the refrigerant carries it indoors, and the coil gives it to the air moving through your ducts. The same unit cools in summer and heats in winter.\u003c\/p\u003e\n\u003cp\u003eBecause the coil sits in the path of the furnace air, the heat is distributed through the same registers as before. No new duct is needed.\u003c\/p\u003e\n\n\u003ch3\u003eThe furnace keeps a role: backup\u003c\/h3\u003e\n\u003cp\u003eA heat pump loses efficiency as the cold intensifies. In an “add-on” installation, the furnace therefore stays in place with its blower, its filters and its heating elements. It takes over when the outdoor temperature drops below a threshold that we set together.\u003c\/p\u003e\n\u003cp\u003eThis threshold is a matter of balance: too low, and you use more energy than necessary with the furnace. Too high, and the heat pump works when it is less efficient. We set it according to the insulation of your home, your electricity rate and your tolerance for the cold.\u003c\/p\u003e\n\n\u003ch3\u003eWhy 2 to 2.5 tons for this type of home\u003c\/h3\u003e\n\u003cp\u003eThe 2 to 2.5 ton size suits homes large enough to need sustained heating and cooling output, such as a two-storey cottage or a large bungalow. A house of this size benefits from a sturdier system in the warm season. But we repeat: the load calculation decides. If the house calls for less, we propose a smaller size from the series.\u003c\/p\u003e\n\n\u003ch3\u003eComparing with the CAUTA neighbours\u003c\/h3\u003e\n\u003cp\u003eWithin the same 2 to 2.5 ton capacity, you can choose among three widths:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCAUTA3022A3: 13 in;\u003c\/li\u003e\n\u003cli\u003eCAUTA3022B3: 16-1\/2 in, this page;\u003c\/li\u003e\n\u003cli\u003eCAUTA3022C3: 20 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor smaller homes, the CAUTA2422 (1.5 to 2 tons) and CAUTA1818 (1.5 tons) exist in 13 in and 16-1\/2 in, and the CAUTA2422C3 in 20 in. R-32, the TXV metering device and the uncased design do not change from one model to the next.\u003c\/p\u003e\n\n\u003ch3\u003eA January evening, in practice\u003c\/h3\u003e\n\u003cp\u003eImagine a January evening in Longueuil, with a clear sky and a sharp cold that is not extreme. The thermostat calls for heat. The outdoor unit starts, draws what heat is left in the outside air and sends it indoors through the refrigerant piping. The coil passes it to the air the blower circulates. The registers blow a soft, steady warmth, without the jolts of electric elements.\u003c\/p\u003e\n\u003cp\u003eIf the temperature drops overnight below the agreed threshold, the furnace kicks in as well. You touch nothing: the whole system switches from one mode to the other on its own and you keep the house at the desired temperature.\u003c\/p\u003e\n\u003ch3\u003eMeasuring the right width\u003c\/h3\u003e\n\u003cp\u003eThe CAUTA3022B3 is 16-1\/2 in wide. The furnace outlet must be of that order so that the air passes through the whole coil. When this is not the case, we build an insulated transition on site, or we propose moving to another width.\u003c\/p\u003e\n\n\u003ch3\u003eWinter efficiency ratings\u003c\/h3\u003e\n\u003cp\u003eThe HSPF2 ratings, which describe heating performance, as well as the SEER2 and EER2 ratings for cooling, are not attached to the coil alone. They describe a certified system, with an AHRI number. We confirm that number before placing the order.\u003c\/p\u003e\n\u003cp\u003eThe ENERGY STAR list contained, when we last checked, no R-32 match-up with this coil. We therefore refer you to the AHRI directory for the outdoor unit chosen.\u003c\/p\u003e\n\n\u003ch3\u003eAnd in summer, the same coil cools\u003c\/h3\u003e\n\u003cp\u003eWhen the warm season returns, the coil resumes its role as evaporator. The air of the house, warmer than the refrigerant evaporating in its tubes, gives up its heat to it. The water the air contained condenses on the fins and goes to the drain. The result is a cool house, and above all a less damp one, with a single unit and a single thermostat for both seasons.\u003c\/p\u003e\n\u003ch3\u003eWhy uncased, and why Goodman\u003c\/h3\u003e\n\u003cp\u003eThe CAUTA3022B3 is supplied uncased: we insert it into the existing plenum or into a casing made to the measurements of the space. This is useful when space is tight or the plenum is in good condition. Goodman, a brand of Daikin Comfort Technologies along with Daikin and Amana, designs its R-32 coils for new-generation heat pumps and central air conditioners, on a furnace or on a modular blower.\u003c\/p\u003e\n\u003ch3\u003eCAUTA3022B3 technical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCAUTA line, uncased coil;\u003c\/li\u003e\n\u003cli\u003enominal size 2 to 2.5 tons (30,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant; leak sensor designed for the life of the coil;\u003c\/li\u003e\n\u003cli\u003ewidth of 16-1\/2 in;\u003c\/li\u003e\n\u003cli\u003eliquid 3\/8 in, suction 3\/4 in;\u003c\/li\u003e\n\u003cli\u003eTXV metering device;\u003c\/li\u003e\n\u003cli\u003eupflow or downflow installation;\u003c\/li\u003e\n\u003cli\u003e10-year limited warranty on parts; registration within 60 days is not required in Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOur installation steps\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. Here is how we proceed:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003etaking the furnace measurements, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003esetting the coil and sealing the connections leak-tight;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit, brazed piping, nitrogen test, vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003estartup, adjustment of the airflow and of the backup threshold, demonstration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOur promise on the load calculation\u003c\/h3\u003e\n\u003cp\u003eBefore writing anything into a quote, we calculate the heating and cooling load of your home. If the 2 to 2.5 ton range is too generous, we say so and propose a smaller model from the series. If it is right, we specify where the match-up falls within that range. You receive the result in writing.\u003c\/p\u003e\n\u003ch3\u003eBefore deciding\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure the furnace outlet: 16-1\/2 in for this model.\u003c\/li\u003e\n\u003cli\u003eCheck with us that the blower provides the required airflow.\u003c\/li\u003e\n\u003cli\u003ePlan for an R-32 outdoor unit, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eAsk for the AHRI number.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eThe complete system, and not the coil alone, is assessed by Hydro-Québec programs. At the time of the quote, we consult the official list according to the installation date, then tell you what is coming to you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and prepare a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402721358116,"sku":"CAUTA3022B3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAUTA_CAUTA3022B3_00_2_A_2_5_TONNES_30000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766080","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-cauta3022b3-a-2-a-2-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}