{"product_id":"serpentin-devaporateur-goodman-cauta3626b3-a-2-a-3-tonnes","title":"GOODMAN CAUTA3626B3 Evaporator A-Coil | 2 to 3 Tons","description":"\u003ch2\u003eCAUTA3626B3: 2 to 3 tons in a 16-1\/2 in furnace, for the typical Greater Montreal bungalow\u003c\/h2\u003e\n\u003cp\u003eA bungalow basement, a narrow furnace, ducts that reach every room, and in summer, two or three window air conditioners humming away. If that sounds like your home, the \u003cstrong\u003eGoodman CAUTA3626B3 coil\u003c\/strong\u003e deserves a look. It offers a nominal capacity of 2 to 3 tons (36,000 BTU\/h), uses R-32 refrigerant, and comes in a 16-1\/2 in wide size.\u003c\/p\u003e\n\n\u003ch3\u003eQuestions and answers about this model\u003c\/h3\u003e\n\u003cp\u003eRather than a long lecture, here are the questions our customers in Montreal, Laval, Longueuil, the North Shore and the South Shore ask us most often.\u003c\/p\u003e\n\n\u003ch3\u003eDoes it replace my window air conditioners?\u003c\/h3\u003e\n\u003cp\u003eYes. The coil sits on the furnace, and the cool air travels through the ducts you already have. A single outdoor unit serves the whole house. Your windows get their light back, and there is no unit to put away in the fall.\u003c\/p\u003e\n\n\u003ch3\u003eDoes it heat too?\u003c\/h3\u003e\n\u003cp\u003eOnly if the outdoor unit is a heat pump. In that case, the coil delivers heat to the air in your home in winter. With a central air conditioner, it is limited to cooling. Either way, the furnace keeps its place: it keeps its blower and its filters.\u003c\/p\u003e\n\n\u003ch3\u003eWhy a 16-1\/2 in coil?\u003c\/h3\u003e\n\u003cp\u003eBecause the width of the furnace dictates the width of the coil. The CAUTA3626B3 is cut for slim units. It is supplied uncased: the coil goes into the existing plenum or into a cabinet built on site. Its A shape suits upflow furnaces well, where the air arrives from below and passes through the two sloped faces.\u003c\/p\u003e\n\u003cp\u003eIf your furnace is wider, we build an insulated transition when needed, but a model of the right width is often simpler.\u003c\/p\u003e\n\n\u003ch3\u003eHow does it differ from the other models in the series?\u003c\/h3\u003e\n\u003cp\u003eHere is a clear way to place the CAUTA3626B3:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAt the same 16-1\/2 in width, the \u003cstrong\u003eCAUTA3026B3\u003c\/strong\u003e is smaller (1.5 to 2.5 tons). The CAUTA3626B3 goes one step beyond it.\u003c\/li\u003e\n\u003cli\u003eAt the same 2 to 3 ton capacity, the \u003cstrong\u003eCAUTA3626C3\u003c\/strong\u003e is 20 in wide.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eCAUTA4230C3\u003c\/strong\u003e and \u003cstrong\u003eCAUTA4230D3\u003c\/strong\u003e go up to 2.5 to 3.5 tons, in 20 in or 23-1\/2 in.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eCAUTA6030C3\u003c\/strong\u003e and \u003cstrong\u003eCAUTA6030D3\u003c\/strong\u003e cover 3.5 to 5 tons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll of these models share R-32, the TXV metering device and the absence of a cabinet. What sets them apart is therefore capacity and width, and we help you decide on both.\u003c\/p\u003e\n\n\u003ch3\u003eHow do you know if 2 to 3 tons is enough?\u003c\/h3\u003e\n\u003cp\u003eWe don't guess. A load calculation weighs the floor area, the insulation in the walls and attic, and the size and orientation of the windows. A single-storey bungalow and a multi-storey cottage do not have the same needs, even with the same footprint.\u003c\/p\u003e\n\u003cp\u003eIf the calculation points to a smaller or larger size, we tell you frankly, even if it means a different model number.\u003c\/p\u003e\n\n\u003ch3\u003eThe coil does not deliver efficiency on its own\u003c\/h3\u003e\n\u003cp\u003eNo efficiency rating is attached to the coil alone. The SEER2, EER2 and HSPF2 ratings describe the certified system, meaning the specific match with an outdoor unit, identified by an AHRI number. When you compare quotes, ask for that number.\u003c\/p\u003e\n\u003cp\u003eWe confirm the match in the AHRI directory before ordering. At our last check, no R-32 match with this coil was listed with ENERGY STAR.\u003c\/p\u003e\n\n\u003ch3\u003eQuick specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLine: Goodman CAUTA, uncased coil;\u003c\/li\u003e\n\u003cli\u003eSize: 2 to 3 tons (36,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003eWidth: 16-1\/2 in;\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-32;\u003c\/li\u003e\n\u003cli\u003eMetering device: TXV;\u003c\/li\u003e\n\u003cli\u003eInstallation positions: upflow or downflow;\u003c\/li\u003e\n\u003cli\u003eConnections: 3\/8 in liquid, 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003eR-32 leak sensor designed to last the life of the coil;\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty, with registration within 60 days (not required in Quebec).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow we install\u003c\/h3\u003e\n\u003cp\u003eAirGreen, a family-run \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01. For this coil and its outdoor unit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ewe measure the furnace and check the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003ewe fit the coil in the plenum and seal the duct connections;\u003c\/li\u003e\n\u003cli\u003ewe install the outdoor unit, braze the piping, pressure test with nitrogen and pull a vacuum;\u003c\/li\u003e\n\u003cli\u003ewe connect the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ewe commission the system, adjust the airflow and explain everything at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCan my old air conditioner stay?\u003c\/h3\u003e\n\u003cp\u003eAlmost never. The coil is designed for R-32 and has to connect to the outdoor unit Goodman intends. It is better to install the two together.\u003c\/p\u003e\n\n\u003ch3\u003eWhat about incentives?\u003c\/h3\u003e\n\u003cp\u003eThey depend on the complete system, not on the coil itself, and on the installation date. We check the official Hydro-Québec list at the time of the quote and spell out what applies to your project.\u003c\/p\u003e\n\n\u003ch3\u003eTo check before you buy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe outdoor unit must use the same refrigerant as the coil.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe blower must be able to deliver the required airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA word on comfort, beyond temperature\u003c\/h3\u003e\n\u003cp\u003eHow cool it feels in July depends as much on humidity as on the thermometer. When the cold coil makes the water in the air condense, the house dries out. A room at a moderate but dry temperature feels better than a cooler but clammy one. That is one of the reasons the people in our projects often tell us summer nights finally become sleepable.\u003c\/p\u003e\n\u003cp\u003eAirflow plays a quiet but real role here. If the ducts are well balanced, each room gets its share and there is no overheated upper floor while the basement shivers. When that is not the case, we point it out during the visit and suggest simple adjustments, such as correcting a damper or sealing a joint.\u003c\/p\u003e\n\n\u003ch3\u003eThe mistakes we see most often\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOrdering a coil before measuring the furnace.\u003c\/li\u003e\n\u003cli\u003eBuying capacity based on floor area alone, without accounting for insulation.\u003c\/li\u003e\n\u003cli\u003eForgetting that the outdoor unit and the coil must share the same refrigerant.\u003c\/li\u003e\n\u003cli\u003eComparing two quotes without asking for the AHRI number of each.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNone of these mistakes is serious when it is caught early. That is exactly why we spend time on site before writing anything up.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if the house changes in five years?\u003c\/h3\u003e\n\u003cp\u003eA renovation, an added bathroom, a basement being finished: the load of the house evolves. A system chosen with a reasonable margin absorbs those changes without flinching. That is another reason to go through the load calculation rather than aim by eye, and to keep the written quote in your records.\u003c\/p\u003e\n\n\u003ch3\u003eA word on noise and discretion\u003c\/h3\u003e\n\u003cp\u003eA well-installed central system stays discreet. The outdoor unit is placed away from the bedrooms and the neighbours' windows, on a stable pad that limits vibration. Indoors, the coil makes no noise by itself; what you hear is the air moving through the ducts.\u003c\/p\u003e\n\u003cp\u003eIf your home is attached to a neighbour's, tell us during the visit: we will choose the outdoor unit's location with the neighbours in mind as much as you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402705727780,"sku":"CAUTA3626B3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAUTA_CAUTA3626B3_00_2_A_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766080","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-cauta3626b3-a-2-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}