{"product_id":"serpentin-devaporateur-goodman-cauta3626c3-a-2-a-3-tonnes","title":"GOODMAN CAUTA3626C3 Evaporator A-Coil | 2 to 3 Tons","description":"\u003ch2\u003eCAUTA3626C3: choosing the right tonnage, 2 to 3 tons, for a 20 in furnace\u003c\/h2\u003e\n\u003cp\u003ePeople often assume bigger means better. In central air conditioning, the opposite happens all too often: an oversized system shuts off before it has dried the air, and the house stays clammy. The \u003cstrong\u003eGoodman CAUTA3626C3 evaporator coil\u003c\/strong\u003e serves a specific need: a nominal capacity of 2 to 3 tons (36,000 BTU\/h), 20 in wide, using R-32. This page helps you judge whether it is the right size for you.\u003c\/p\u003e\n\n\u003ch3\u003eFirst, the logic of tonnage\u003c\/h3\u003e\n\u003cp\u003eA system's capacity should follow the needs of the house, not the salesperson's whim. A well-insulated home with few south-facing windows needs less than a home with a poorly insulated roof. That is why we do a load calculation before proposing a model.\u003c\/p\u003e\n\u003cp\u003eThe 2 to 3 ton size sits in the middle of the series. It suits many bungalows and cottages, especially those where the insulation has been redone and the basement is partly finished.\u003c\/p\u003e\n\n\u003ch3\u003eWhat an oversized system really costs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCycles that are too short: the air cools quickly but stays humid.\u003c\/li\u003e\n\u003cli\u003eFaster wear on the components that start and stop constantly.\u003c\/li\u003e\n\u003cli\u003eA higher purchase price, with no gain in comfort.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAn undersized system has its own drawbacks, of course: it struggles during heat waves. The load calculation looks for the balance between the two.\u003c\/p\u003e\n\n\u003ch3\u003eWhy the C3: the 20 in width\u003c\/h3\u003e\n\u003cp\u003eIn this series, the C suffix in the model number corresponds to a 20 in width. That is a common dimension for residential furnaces. The coil goes into the plenum, or into a cabinet built on site since it is supplied uncased. If your furnace is a different width, we build an insulated transition when needed.\u003c\/p\u003e\n\u003cp\u003eThe A shape provides two sloped faces that meet at the top, and the TXV metering device adjusts the refrigerant flow to demand. The published installation positions are upflow or downflow.\u003c\/p\u003e\n\n\u003ch3\u003ePlacing the CAUTA3626C3 on the series scale\u003c\/h3\u003e\n\u003cp\u003eHere is how to get your bearings:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCAUTA3026C3\u003c\/strong\u003e: also 20 in, but 1.5 to 2.5 tons. One step smaller.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAUTA3626B3\u003c\/strong\u003e: the same 2 to 3 ton capacity, in 16-1\/2 in for a slim furnace.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAUTA4230C3\u003c\/strong\u003e: also 20 in, but 2.5 to 3.5 tons. One step larger.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAUTA6030C3\u003c\/strong\u003e: 20 in, 3.5 to 5 tons.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAUTA3026B3\u003c\/strong\u003e, \u003cstrong\u003eCAUTA4230D3\u003c\/strong\u003e and \u003cstrong\u003eCAUTA6030D3\u003c\/strong\u003e round out the series in 16-1\/2 in or 23-1\/2 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAt home, width and tonnage are settled separately. Once the width is known, you still have to choose the capacity: that is where the load calculation comes in.\u003c\/p\u003e\n\n\u003ch3\u003eThe coil, the outdoor unit and the AHRI number\u003c\/h3\u003e\n\u003cp\u003eThe coil has no efficiency rating on its own. The SEER2, EER2 and HSPF2 ratings belong to the certified set. It is the AHRI number that links a specific coil to a specific outdoor unit. We confirm that match before buying, so that the ratings promised are the ones you get.\u003c\/p\u003e\n\u003cp\u003eA useful point: at our last check, no R-32 match with this coil was listed with ENERGY STAR. We tell you what the AHRI directory says for the outdoor unit selected.\u003c\/p\u003e\n\n\u003ch3\u003eCAUTA3626C3 specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Goodman;\u003c\/li\u003e\n\u003cli\u003eType: uncased evaporator coil;\u003c\/li\u003e\n\u003cli\u003eNominal size: 2 to 3 tons (36,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-32;\u003c\/li\u003e\n\u003cli\u003eWidth: 20 in;\u003c\/li\u003e\n\u003cli\u003eLiquid connection: 3\/8 in; suction connection: 7\/8 in;\u003c\/li\u003e\n\u003cli\u003eMetering device: TXV;\u003c\/li\u003e\n\u003cli\u003eLeak detection: R-32 refrigerant sensor designed to last the life of the coil;\u003c\/li\u003e\n\u003cli\u003eWarranty: 10-year limited parts warranty, online registration within 60 days (not required in Quebec).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe furnace is still useful\u003c\/h3\u003e\n\u003cp\u003eWith a heat pump as the outdoor unit, the furnace keeps its blower, its filters and its role as backup heat. It takes over below the temperature threshold we set with you. It does not disappear from the picture; it simply moves from the lead role to a supporting one.\u003c\/p\u003e\n\n\u003ch3\u003eHow a project with AirGreen unfolds\u003c\/h3\u003e\n\u003cp\u003eA family-run \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years, AirGreen carries out its refrigeration, ventilation and electrical work under RBQ licence 5645-9605-01. We work in Montreal, Laval, Longueuil, the North Shore and the South Shore, with the following steps:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003efitting the coil and sealing the duct connections;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit, brazed piping, nitrogen pressure test and vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and explanations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCan you keep your current air conditioner?\u003c\/h3\u003e\n\u003cp\u003eGenerally, no: the R-32 coil has to connect to the outdoor unit the manufacturer intends. We install the complete system.\u003c\/p\u003e\n\n\u003ch3\u003eTo check before choosing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDo the coil and the outdoor unit share the same refrigerant?\u003c\/li\u003e\n\u003cli\u003eDoes the certified match correspond to what you are being offered?\u003c\/li\u003e\n\u003cli\u003eDoes the furnace blower deliver the system's airflow?\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs apply to the complete system, depending on the installation date, and not to the coil alone. We check the official list at the time of the quote.\u003c\/p\u003e\n\n\u003ch3\u003eWhen a heat pump takes over the heating\u003c\/h3\u003e\n\u003cp\u003eThe Quebec winter sets its own rules. A heat pump moves heat from the outdoor air to the inside, and its output drops as the temperature falls. That is why we don't remove the furnace: it becomes the complement that takes over on the coldest days. We set the switchover threshold with you, based on your comfort and your electricity bill.\u003c\/p\u003e\n\u003cp\u003eThis division of labour has a concrete advantage: you don't need to oversize the heat pump to cover the cold peak. The system stays a reasonable size, and the furnace handles the few extreme days.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we can't promise\u003c\/h3\u003e\n\u003cp\u003eWe won't announce a precise dollar saving before we have seen your house, your ducts and your habits. Those figures depend on too many factors: insulation, the thermostat, the way you use the rooms. What we can give you is a clear quote, a certified match and an installation done by the book.\u003c\/p\u003e\n\n\u003ch3\u003eA simple step to extend the life of the system\u003c\/h3\u003e\n\u003cp\u003eRegularly clear the area around the outdoor unit of snow, leaves and branches. Air has to flow freely around it, and it is maintenance you can do yourself without tools. For the rest, the filter, the drain and the connections are part of an annual visit from us.\u003c\/p\u003e\n\n\u003ch3\u003eHow to compare two quotes\u003c\/h3\u003e\n\u003cp\u003ePlace the two documents side by side. Look for the exact name of the coil, the name of the outdoor unit, the AHRI number of the match and the list of work. If even one of these items is missing on one side, you are not comparing two equivalent offers.\u003c\/p\u003e\n\u003cp\u003eWe are comfortable with that comparison: our written quote is designed to be read, line by line, by someone who is not in the trade.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402706022692,"sku":"CAUTA3626C3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CAUTA_CAUTA3626C3_00_2_A_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766080","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-cauta3626c3-a-2-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}