{"product_id":"serpentin-devaporateur-goodman-chpea3626c3-a-3-tonnes","title":"GOODMAN CHPEA3626C3 Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003eGoodman CHPEA3626C3: five questions to ask before choosing this 3-ton coil\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eCHPEA3626C3\u003c\/strong\u003e is a cased evaporator A-coil from the Goodman CHPEA line. It delivers 3 tons (36,000 BTU\/h), uses \u003cstrong\u003eR-32\u003c\/strong\u003e and measures 26 × 21 × 21 in. (W × H × D). It installs on a furnace or a blower cabinet to cool in summer and, with a heat pump, heat in winter.\u003c\/p\u003e\n\u003cp\u003eRather than lining up numbers, this page follows the five questions that our customers in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e ask us most often before signing a quote.\u003c\/p\u003e\n\n\u003ch3\u003eQuestion one: does my home really need 3 tons?\u003c\/h3\u003e\n\u003cp\u003eThe 3-ton size is often the starting point for medium to large homes. But the right size depends on the floor area, the number of exposed windows, the insulation and the number of floors served. We do the calculation room by room. If the result comes in lower, we steer you toward 2.5 tons (CHPEA3026B3 or CHPEA3026C3). If it comes in higher, we look at the 4-ton models.\u003c\/p\u003e\n\n\u003ch3\u003eQuestion two: what cabinet height will my plenum accept?\u003c\/h3\u003e\n\u003cp\u003eThe C3 is the taller model of the pair: 21 in., while the CHPEA3626B3 has a lower cabinet. Both share the same 26 in. width, the same capacity and the same EEV expansion valve. If the distance between the top of the furnace and the ceiling is comfortable, the C3 poses no problem. If it is tight, we will propose the B3 instead.\u003c\/p\u003e\n\u003cp\u003eOne tip: do not count on an approximate measurement. We bring a tape measure and take the time to also check the clearance needed to service the coil.\u003c\/p\u003e\n\n\u003ch3\u003eQuestion three: which outdoor unit will it be paired with?\u003c\/h3\u003e\n\u003cp\u003eThe data sheet for this coil does not list a specific pairing; we therefore confirm it with you before the order. The principle remains simple: a Goodman outdoor unit with the same refrigerant and an equivalent capacity, certified with this coil in the AHRI directory. The AHRI number of the system is given to you in writing, and it is what guarantees that the SEER2, EER2 and HSPF2 ratings are really those of your installation.\u003c\/p\u003e\n\u003cp\u003eAlways ask for this number from whoever quotes you. Two prices can only be compared if the systems can be compared.\u003c\/p\u003e\n\n\u003ch3\u003eQuestion four: what happens inside the coil?\u003c\/h3\u003e\n\u003cp\u003eImagine a radiator in reverse. The cold refrigerant evaporates in the tubes and absorbs heat from the air passing between the fins. The condensation water drops into the pan and runs to the drain. The cooled air leaves through the existing ducts.\u003c\/p\u003e\n\u003cp\u003eWith a heat pump, the cycle reverses in winter. The furnace keeps its blower, its filters and its role as backup heat when the outdoor thermometer drops below the threshold we set together.\u003c\/p\u003e\n\n\u003ch3\u003eQuestion five: where does it sit compared with the other models?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCHPEA3626B3\u003c\/strong\u003e: same capacity, lower cabinet.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCHPEA3026B3\u003c\/strong\u003e and \u003cstrong\u003eCHPEA3026C3\u003c\/strong\u003e: 2.5 tons, 26 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCHPEA2422B3\u003c\/strong\u003e: 2 tons, 22 in., with the GZV6SA1810A.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAHEA3630C3\u003c\/strong\u003e: 2 to 5 tons, 21 in. wide, three published pairings.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCHPEA4830C3\u003c\/strong\u003e and \u003cstrong\u003eCHPEA4830D3\u003c\/strong\u003e: 4 tons, 30 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCHPEA6030C3\u003c\/strong\u003e and \u003cstrong\u003eCHPEA6030D3\u003c\/strong\u003e: 5 tons, 30 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll of them run on R-32 with an EEV expansion valve; width and height are therefore your real selection criteria.\u003c\/p\u003e\n\n\u003ch3\u003eAnd what if my ducts are old?\u003c\/h3\u003e\n\u003cp\u003eThat is an excellent question, and one that is rarely asked. A new coil does not fix a poorly designed or poorly sealed duct system. We look at the supply runs, the return air and the condition of the joints. If a duct leaks inside a wall or in the attic, part of the cool air never reaches the room. We show you what we see, propose a correction if it is useful and put it clearly in the quote.\u003c\/p\u003e\n\n\u003ch3\u003eQuick answers\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this model heat?\u003c\/strong\u003e Yes, with a heat pump. With a central air conditioner, it only provides cooling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my current outdoor unit?\u003c\/strong\u003e Generally not, because of R-32.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy furnace has a different width?\u003c\/strong\u003e We build an insulated transition on site.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still used?\u003c\/strong\u003e Yes: its blower works all year and it provides backup in extreme cold.\u003c\/p\u003e\n\n\u003ch3\u003eWhen to schedule the work\u003c\/h3\u003e\n\u003cp\u003eMany people wait for the first heat wave to call, and that is understandable. Yet the most pleasant time to have a coil installed is when the house does not need the system: in spring or fall, the crew works without rushing, appointments are more flexible and the furnace can be shut off for a few hours without discomfort. If you are aiming for a heat pump for winter, call before the first cold snap; the assessment visit is free and carries no obligation.\u003c\/p\u003e\n\n\u003ch3\u003eSpec sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003econnections: 5\/16 or 3\/8 in. on the liquid side, 3\/4 or 7\/8 in. on the suction side;\u003c\/li\u003e\n\u003cli\u003eposition: horizontal according to the manufacturer's data sheet;\u003c\/li\u003e\n\u003cli\u003eleak detection: R-32 refrigerant sensor designed to last the life of the coil (data sheet SS-DCoil-R32);\u003c\/li\u003e\n\u003cli\u003ewarranty: 10-year limited parts warranty, with online registration within 60 days of installation, not required in Quebec (Goodman data sheet SS-GCoil-R32).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy homeowners switch to a heat pump\u003c\/h3\u003e\n\u003cp\u003eBaseboards and electric furnaces turn every kilowatt-hour into an equal amount of heat. A heat pump does something else: it carries heat from outdoors into the house, and in mild weather, it provides two to three times as much as the electricity it uses. This advantage shrinks in the cold, but the furnace takes over. In summer, the same equipment replaces window air conditioners.\u003c\/p\u003e\n\u003cp\u003eGoodman is a brand of Daikin Comfort Technologies, like Daikin and Amana. Its R-32 pairings with the GZV6SA, GZV7SA and GZV9SA heat pumps are ENERGY STAR and cold-climate certified, on a Goodman MBVK modular blower.\u003c\/p\u003e\n\n\u003ch2\u003eHow AirGreen installs this coil\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years. Refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. The installation includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, testing the blower and inspecting the electrical panel;\u003c\/li\u003e\n\u003cli\u003econnecting the cabinet to the plenum, with an insulated transition if needed, and tight joints;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit on a pad, brazed piping, the nitrogen test and the vacuum;\u003c\/li\u003e\n\u003cli\u003ethe condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003estartup, airflow adjustment and handing over the operating instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFinal checks\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 refrigerant on both sides, outdoor unit installed at the same time.\u003c\/li\u003e\n\u003cli\u003eRatings valid for the certified pairing only.\u003c\/li\u003e\n\u003cli\u003eFurnace of the right width, adequate blower and sufficient vertical clearance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eAlso keep a photo of your furnace nameplate: it lets us prepare the visit and confirm compatibility with this coil's cabinet more quickly, even before we arrive at your home.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert subsidy and other programs\u003c\/h3\u003e\n\u003cp\u003eEligibility for Hydro-Québec programs, including LogisVert, depends on the complete system, not on the coil alone. We consult the official list on the date of the quote and tell you what applies to your case.\u003c\/p\u003e\n\n\u003ch3\u003eYour free estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBook a visit: we measure the furnace, check the electrical service and write up a quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e helps spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402717491492,"sku":"CHPEA3626C3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CHPEA_CHPEA3626C3_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766077","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-chpea3626c3-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}