{"product_id":"serpentin-devaporateur-goodman-chpea6030c3-a-5-tonnes","title":"GOODMAN CHPEA6030C3 Evaporator A-Coil | 5 Tons","description":"\u003ch2\u003eCHPEA6030C3: 5 tons and 30 in. wide, with a 21 in. tall cabinet\u003c\/h2\u003e\n\u003cp\u003eIn the series of Goodman coils that we install, the \u003cstrong\u003eCHPEA6030C3\u003c\/strong\u003e is one of the largest sizes: 5 tons, or 60,000 BTU\/h nominal size. It is a cased evaporator A-coil from the CHPEA line, running on \u003cstrong\u003eR-32\u003c\/strong\u003e with an EEV expansion valve, and its cabinet measures 30 × 21 × 21 in. (W × H × D). It sits on a furnace or a blower cabinet.\u003c\/p\u003e\n\u003cp\u003eA size like this is not for everyone. This page answers one simple question: is it the right tool for your home, in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e or on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e?\u003c\/p\u003e\n\n\u003ch3\u003eWhen five tons make sense\u003c\/h3\u003e\n\u003cp\u003eA 5-ton coil is meant for large homes: big cottages, semi-detached homes with several floors under a single furnace, properties with high ceilings and large windows. It may also suit a home whose ducts were designed for a large volume of air.\u003c\/p\u003e\n\u003cp\u003eBut a large size is not always the right answer. In some very spread-out homes, two smaller systems, each with its own zone, give better comfort and more flexibility. We assess both possibilities with you, with no pressure.\u003c\/p\u003e\n\n\u003ch3\u003eThe pairing table\u003c\/h3\u003e\n\u003cp\u003eGoodman has certified three combinations with this coil:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eGZV7SA4210A\u003c\/strong\u003e outdoor unit, AHRI 215433945, cooling 41,000 BTU\/h, heating 41,000 BTU\/h at 47 °F, SEER2 17.5, HSPF2 8.8;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGZV7SA4810A\u003c\/strong\u003e outdoor unit, AHRI 215433964, cooling 45,500 BTU\/h, heating 46,500 BTU\/h at 47 °F, SEER2 17.5, HSPF2 8.5;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGZV9SA6010A\u003c\/strong\u003e outdoor unit, AHRI 217989268, cooling 52,000 BTU\/h, heating 52,500 BTU\/h at 47 °F, SEER2 16.0, HSPF2 8.5.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eReading closely, you can see a trade-off: as the capacity of the outdoor unit increases, the published rating drops: SEER2 17.5 for the two GZV7SA units, SEER2 16.0 for the GZV9SA6010A. In other words, the GZV9SA6010A offers the largest capacity of the three, while the two GZV7SA units show a higher cooling rating. The right choice therefore depends on your real needs, not on an isolated number.\u003c\/p\u003e\n\n\u003ch3\u003eThe three checks of a large installation\u003c\/h3\u003e\n\u003cp\u003eAt this size, three elements determine the result:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003ethe electrical service\u003c\/strong\u003e: the outdoor unit's circuit must be able to be powered without improvising;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ethe blower\u003c\/strong\u003e: it must supply the airflow required by a 5-ton system;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ethe duct network\u003c\/strong\u003e: sizing, return air, tightness, everything counts so that the air reaches every room.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe check these three points before quoting, and we tell you frankly if a correction is needed.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the coil does in the home\u003c\/h3\u003e\n\u003cp\u003eIt is installed in the plenum, right after the blower. The air passes through the two faces of the letter A. In summer, the refrigerant, as it evaporates, absorbs heat and humidity; the water runs into the pan and leaves through the drain. With a heat pump, the cycle reverses in winter and the outdoor heat is delivered to the air in the house.\u003c\/p\u003e\n\u003cp\u003eThe furnace keeps its blower, its filters and its backup role, starting at a temperature threshold that we set together.\u003c\/p\u003e\n\n\u003ch3\u003eC3 or D3?\u003c\/h3\u003e\n\u003cp\u003eThe CHPEA6030C3 and CHPEA6030D3 are alike in almost every way: same 5-ton capacity, same 30 in. width, same three pairings, same R-32, same EEV expansion valve. The C3 you are reading about has the lower cabinet of the two; the D3 is taller. Your plenum decides: little clearance, the C3; plenty of room, the two models are equal.\u003c\/p\u003e\n\u003ch3\u003eHow it fits in the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne step down: the \u003cstrong\u003eCHPEA4830C3\u003c\/strong\u003e and \u003cstrong\u003eCHPEA4830D3\u003c\/strong\u003e, which offer 4 tons on 30 in., with the GZV7SA3610A.\u003c\/li\u003e\n\u003cli\u003eFor 26 in. furnaces: the \u003cstrong\u003eCHPEA3626B3\u003c\/strong\u003e and \u003cstrong\u003eCHPEA3626C3\u003c\/strong\u003e (3 tons) as well as the \u003cstrong\u003eCHPEA3026B3\u003c\/strong\u003e and \u003cstrong\u003eCHPEA3026C3\u003c\/strong\u003e (2.5 tons).\u003c\/li\u003e\n\u003cli\u003eFor small homes: the \u003cstrong\u003eCHPEA2422B3\u003c\/strong\u003e, 2 tons, 22 in.\u003c\/li\u003e\n\u003cli\u003eFor narrow furnaces: the \u003cstrong\u003eCAHEA3630C3\u003c\/strong\u003e, 2 to 5 tons, 21 in. wide.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat \"a large installation\" means in practice\u003c\/h3\u003e\n\u003cp\u003eWhen you move up to 5 tons, the outdoor unit is bulkier and its location deserves thought: clearance around the unit, access for maintenance, the route of the piping to the plenum. We mark out the location with you before the order. On a narrow lot in Montreal, or on a more open suburban lot in Laval or on the North Shore, the constraints are not the same, and we adapt the installation accordingly.\u003c\/p\u003e\n\n\u003ch3\u003eSpec sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eliquid connection: 3\/8 in.; suction connection: 7\/8 or 1-1\/8 in.;\u003c\/li\u003e\n\u003cli\u003eposition: horizontal according to the manufacturer's data sheet;\u003c\/li\u003e\n\u003cli\u003eleak detection: R-32 refrigerant sensor designed to last the life of the coil (data sheet SS-DCoil-R32);\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty, with online registration within 60 days of installation (not required in Quebec; data sheet SS-GCoil-R32).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe heat pump advantage in a large home\u003c\/h3\u003e\n\u003cp\u003eThe larger the home, the more heating weighs on the bill. Conventional electric heating gives as much heat as the electricity consumed. A heat pump moves outdoor heat: in mild weather, it produces two to three times as much. Its efficiency decreases with the cold, and the furnace then takes the work back. In summer, a single system cools the whole house, and the air becomes drier.\u003c\/p\u003e\n\u003cp\u003eGoodman is part of Daikin Comfort Technologies, like Daikin and Amana. Its R-32 pairings with the GZV6SA, GZV7SA and GZV9SA heat pumps are ENERGY STAR and cold-climate certified, on a Goodman MBVK modular blower.\u003c\/p\u003e\n\n\u003ch2\u003eHow an AirGreen installation unfolds\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years. Refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01. For this coil:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ewe measure the furnace and check the blower as well as the electrical panel;\u003c\/li\u003e\n\u003cli\u003ewe install the cabinet in the plenum, with an insulated transition if needed, and seal the connections;\u003c\/li\u003e\n\u003cli\u003ewe install the outdoor unit, braze the piping, perform the nitrogen test and pull the vacuum;\u003c\/li\u003e\n\u003cli\u003ewe connect the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ewe start up the system, adjust the airflow and explain how it works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eBefore signing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe outdoor unit must be R-32 and installed at the same time as the coil.\u003c\/li\u003e\n\u003cli\u003eThe ratings correspond to the selected certified pairing.\u003c\/li\u003e\n\u003cli\u003eThe furnace must have the necessary width, blower and clearance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eAlso keep last winter's electricity bills if you have them: they give a concrete point of comparison for discussing the possible gain with a heat pump, in a home of this size.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert subsidy\u003c\/h3\u003e\n\u003cp\u003eThe paired Goodman system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we validate it against the official list when we prepare your quote and put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eBook your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free in-home estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e lets you spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402705760548,"sku":"CHPEA6030C3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CHPEA_CHPEA6030C3_00_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766101","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-chpea6030c3-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}