{"product_id":"serpentin-devaporateur-goodman-chpta1822b3-a-1-5-tonnes","title":"GOODMAN CHPTA1822B3 Evaporator A-Coil | 1.5 Tons","description":"\u003ch2\u003eGoodman CHPTA1822B3 coil: 1.5 ton, 22 in wide and a cabinet 17-1\/2 in high\u003c\/h2\u003e\n\u003cp\u003eA plex owner in Laval once asked us this question: \"My ground-floor unit is small, my furnace is narrow, but my basement is fairly high. Do I really have to take the smallest coil possible?\" The short answer is no. When height is not a problem, the \u003cstrong\u003eGoodman CHPTA1822B3 evaporator coil\u003c\/strong\u003e is often the most logical choice for a 1.5 ton system.\u003c\/p\u003e\n\u003cp\u003eIt is the same size as the CHPTA1822A3, with the same width, the same R-32 and the same TXV. What sets it apart is a taller cabinet: 22 × 17-1\/2 × 21 in. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhy two coils for the same capacity?\u003c\/h3\u003e\n\u003cp\u003eTwo 1.5 ton models exist in the range because furnaces do not all have the same free volume above the heat exchanger. The A3 is the shorter of the two; the B3 rises to 17-1\/2 in. The second leaves a longer air path above the cabinet, which can make the transition to the supply plenum easier and leave the coil less cramped to reach later, at the time of maintenance.\u003c\/p\u003e\n\u003cp\u003eIn practice, if your plenum is already tall and clear, the B3 fits in without moving anything. If the ceiling is right overhead, the A3 has the advantage. We take measurements before deciding, and the decision is made on site.\u003c\/p\u003e\n\n\u003ch3\u003eHow the coil works\u003c\/h3\u003e\n\u003cp\u003eMounted on the furnace, it receives liquid refrigerant from the outdoor unit through the 3\/8 in line. The fluid expands in the TXV, evaporates in the fins and returns outside through the 3\/4 in suction line. Along the way, the air in the house, pushed by the blower, is cooled and loses some of its moisture. The water collected in the pan flows to the drain.\u003c\/p\u003e\n\u003cp\u003eWith a heat pump upstream, the same path is used for heating: the heat captured outdoors is given up to the air circulating in your existing ducts.\u003c\/p\u003e\n\n\u003ch3\u003eCHPTA1822B3 spec sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased A-coil evaporator, CHPTA range;\u003c\/li\u003e\n\u003cli\u003enominal size: 1.5 ton (18,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-32;\u003c\/li\u003e\n\u003cli\u003edimensions W × H × D: 22 × 17-1\/2 × 21 in;\u003c\/li\u003e\n\u003cli\u003eliquid connection: 3\/8 in; suction connection: 3\/4 in;\u003c\/li\u003e\n\u003cli\u003emetering device: TXV;\u003c\/li\u003e\n\u003cli\u003epublished position: horizontal;\u003c\/li\u003e\n\u003cli\u003eR-32 leak sensor designed to last the life of the coil;\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty; online registration within 60 days of installation, not required in Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA detail that matters in summer: the pan and the drain\u003c\/h3\u003e\n\u003cp\u003eIn a small home, condensation water is easy to forget until the day it overflows. The pan under the coil collects the water, then the drain carries it to a floor drain or a pump. We inspect the whole path: drain slope, access for cleaning and clearance around the cabinet. A taller cabinet like the B3's leaves a little more room for a hand during this annual check.\u003c\/p\u003e\n\u003cp\u003eThink about the filter too. A clean filter spares the blower and protects the coil fins from dust. We show you where it is and how to replace it, so that basic upkeep becomes part of your routine.\u003c\/p\u003e\n\n\u003ch3\u003eA system well sized for a small volume\u003c\/h3\u003e\n\u003cp\u003eIn a compact home, the temptation is to inflate the capacity \"just in case\". But an oversized system reaches the setpoint quickly, shuts off, then restarts: it never runs long enough to dry the air. You get cold without comfort. So we run the load calculation before recommending a size, taking into account insulation, windows and sun exposure.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the match changes\u003c\/h3\u003e\n\u003cp\u003eThis coil pairs with a Goodman outdoor unit of the same capacity and the same refrigerant. The two parts are installed together. No efficiency rating is attached to the coil alone: SEER2, EER2 and HSPF2 relate to the complete system, identified by an AHRI number. We verify it before the order so that the advertised ratings are the ones you will actually get.\u003c\/p\u003e\n\u003cp\u003eA useful note: as of 2026-11-26, no R-32 match with this coil appears in the ENERGY STAR data set. The outdoor unit chosen is therefore validated in the AHRI directory.\u003c\/p\u003e\n\n\u003ch3\u003eB3 or another model? A short guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eYou are weighing it against the CHPTA1822A3\u003c\/strong\u003e: same capacity and same width, but a shorter cabinet. Choose it only if height is tight;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eYour furnace is 26 in wide\u003c\/strong\u003e: look at the CHPTA2426B3 or the CHPTA2426C3, which cover 1.5 to 2 tons;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eYour needs exceed 2 tons\u003c\/strong\u003e: the CHPTA3026B3 and CHPTA3026C3 cover 2 to 2.5 tons, then the series climbs to 4 to 5 tons with the CHPTA6030D3;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAll models\u003c\/strong\u003e use R-32 and the TXV: the choice therefore comes down to capacity, width and height.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAnd what happens to my furnace?\u003c\/h3\u003e\n\u003cp\u003eIt stays. Its blower pushes the air, its filters clean it, and it serves as backup heat during the coldest weather when the outdoor unit is a heat pump. We set with you the temperature below which it takes over. We only need to confirm that the blower can reach the airflow the system calls for.\u003c\/p\u003e\n\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eAirGreen, a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. At your home, we do the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasure the furnace and check the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstall the cabinet and, if needed, a custom-built insulated transition;\u003c\/li\u003e\n\u003cli\u003einstall the outdoor unit on a stand, run brazed copper piping, and do the nitrogen test and vacuum;\u003c\/li\u003e\n\u003cli\u003econnect the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003estart up the system, balance the airflow and show you how to use it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePoints to confirm before signing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 requires a match with an outdoor unit using the same refrigerant.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified system.\u003c\/li\u003e\n\u003cli\u003eThe 22 in width and the furnace blower must be suitable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe manufacturer behind the coil\u003c\/h3\u003e\n\u003cp\u003eGoodman belongs to Daikin Comfort Technologies, as do Daikin and Amana. The brand's R-32 range goes with new-generation central air conditioners and heat pumps, on a furnace or on a modular blower.\u003c\/p\u003e\n\n\u003ch3\u003eFinancial assistance\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs assess the complete system according to the installation date, not the coil taken alone. We consult the official list when we prepare your quote and explain clearly what applies.\u003c\/p\u003e\n\n\u003ch3\u003eTake the next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402708119844,"sku":"CHPTA1822B3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CHPTA_CHPTA1822B3_00_1_5_TONNES_18000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766117","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-chpta1822b3-a-1-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}