{"product_id":"serpentin-devaporateur-goodman-chpta2426b3-a-1-5-a-2-tonnes","title":"GOODMAN CHPTA2426B3 Evaporator A-Coil | 1.5 to 2 Tons","description":"\u003ch2\u003eCHPTA2426B3: the 1.5 to 2 ton Goodman coil for homes in the grey zone between small and medium\u003c\/h2\u003e\n\u003cp\u003eSome homes fall exactly between two sizes in the calculations. Not small enough for 1.5 ton, not big enough for 2.5 tons. A renovated bungalow on the South Shore with new windows, a Montreal duplex with a well-insulated upper floor, a semi-detached home in Laval with a half-finished basement: these are the typical customers for the \u003cstrong\u003eGoodman CHPTA2426B3 evaporator coil\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is a cased A-coil using \u003cstrong\u003eR-32\u003c\/strong\u003e, with a nominal range covering 1.5 to 2 tons (24,000 BTU\/h) on a width of 26 in. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhy a range and not a single figure\u003c\/h3\u003e\n\u003cp\u003eThe \"1.5 to 2 tons\" label means this coil can be paired with outdoor units of different capacity within that span. It is your home's load calculation that determines the choice, not a rough rule based on floor area. Two homes of the same size can have very different needs depending on their insulation, windows and orientation.\u003c\/p\u003e\n\u003cp\u003eWe recommend the outdoor unit that fits the calculated load, then we confirm the match with the coil in the AHRI directory, which assigns a number to each certified combination.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the 26 in width tells you\u003c\/h3\u003e\n\u003cp\u003eThe dimensions are 26 × 17-1\/2 × 21 in. The jump from 22 in to 26 in of width compared with the 1.5 ton models is no small detail: it follows the furnace and the airflow that passes through the coil. More fin surface exposes the air to more refrigerant, which sets the stage for the added capacity.\u003c\/p\u003e\n\u003cp\u003eIf your furnace has a different width, we measure and build an insulated transition on site. It is a routine job for us.\u003c\/p\u003e\n\n\u003ch3\u003eThe numbers to know\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: CHPTA2426B3, cased coil, CHPTA range;\u003c\/li\u003e\n\u003cli\u003enominal range: 1.5 to 2 tons, or 24,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-32;\u003c\/li\u003e\n\u003cli\u003emetering device: TXV;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in for liquid and 7\/8 in for suction;\u003c\/li\u003e\n\u003cli\u003epublished installation position: horizontal;\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant sensor designed to last the life of the coil;\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty, online registration within 60 days of installation (not required in Quebec).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe suction line is larger than on the 22 in models: it goes with a higher refrigerant flow.\u003c\/p\u003e\n\n\u003ch3\u003eA simple test: is your home a candidate?\u003c\/h3\u003e\n\u003cp\u003eAnswer these questions honestly, then compare with our calculation during the visit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn summer, does the heat build up mostly upstairs or in a south-facing room?\u003c\/li\u003e\n\u003cli\u003eIs your current furnace close to 26 in wide?\u003c\/li\u003e\n\u003cli\u003eWere you offered a small 1.5 ton system, but you worry it will run out of steam on heat wave days?\u003c\/li\u003e\n\u003cli\u003eDoes a 2.5 ton system seem oversized for your floor area?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf you answer yes to two or three of these questions, this coil deserves serious consideration.\u003c\/p\u003e\n\n\u003ch3\u003eB3 or C3: the cabinet question\u003c\/h3\u003e\n\u003cp\u003eThe CHPTA2426C3 shares the capacity, the 26 in width, the R-32 and the TXV. It has a taller cabinet. Our rule is simple: if the space above the furnace is limited, the B3 is preferable; if there is height, the C3 offers a roomier air path. We decide nothing before checking the plenum.\u003c\/p\u003e\n\n\u003ch3\u003eThe neighbours in the series at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCHPTA1822A3 and CHPTA1822B3\u003c\/strong\u003e: 1.5 ton, 22 in wide; for narrower furnaces and small homes;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCHPTA3026B3 and CHPTA3026C3\u003c\/strong\u003e: 2 to 2.5 tons, still 26 in wide. Same footprint as this one, more capacity;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCHPTA3630B3, CHPTA3630C3 and CHPTA4230C3\u003c\/strong\u003e: from 2.5 tons to 3.5 tons, on a 30 in width;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCHPTA4830C3 and CHPTA6030D3\u003c\/strong\u003e: from 3.5 tons to 5 tons, also on 30 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat you will notice day to day\u003c\/h3\u003e\n\u003cp\u003eA well-matched coil is easy to forget, and that is the whole point. In July, the air comes out of the grilles cooler and noticeably drier, the clammy feeling disappears from room to room and the thermostat stops calling for short cycles. In winter, with a heat pump, the heat arrives milder and steadier than from a furnace that fires up hard and then shuts off.\u003c\/p\u003e\n\u003cp\u003eNoise is also a good measure: a system whose capacity is well chosen runs at a moderate speed most of the time. An oversized system, on the other hand, shows itself through repeated starts that you can hear throughout the house.\u003c\/p\u003e\n\n\u003ch3\u003eThe match and the efficiency ratings\u003c\/h3\u003e\n\u003cp\u003eThe coil pairs with a Goodman outdoor unit of the same capacity and the same refrigerant, installed at the same time. It carries no efficiency rating of its own: SEER2, EER2 and HSPF2 belong to the certified system. To compare two quotes, always ask for the AHRI number. As of 2026-11-26, no R-32 match with this coil is listed with ENERGY STAR in the data set we consulted.\u003c\/p\u003e\n\n\u003ch3\u003eWhat a heat pump does that electricity alone does not\u003c\/h3\u003e\n\u003cp\u003eA baseboard heater or an electric furnace converts each unit of electricity into one unit of heat. A heat pump instead moves the heat present outdoors to the inside: in mild weather, it delivers two to three times the energy it consumes. When it is very cold, this ratio drops, and the furnace takes over at the threshold we program with you.\u003c\/p\u003e\n\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. The job includes:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003emeasuring the furnace and plenum, then checking the blower and the electrical entrance;\u003c\/li\u003e\n\u003cli\u003einstalling the cabinet, with a transition built if needed, and sealing the joints;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit, brazed piping, nitrogen test and vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and a full explanation of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eTo confirm before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 refrigerant: the outdoor unit must be of the same type.\u003c\/li\u003e\n\u003cli\u003eThe published ratings correspond to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe furnace must offer the 26 in width and a blower capable of the airflow required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eGoodman in two lines\u003c\/h3\u003e\n\u003cp\u003eThe brand is a division of Daikin Comfort Technologies, which also owns Daikin and Amana. Its R-32 coils install on a furnace or on a modular blower.\u003c\/p\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs apply to the complete system. We check the official list against the installation date and tell you what applies before you sign.\u003c\/p\u003e\n\n\u003ch3\u003eGet your quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402708840740,"sku":"CHPTA2426B3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CHPTA_CHPTA2426B3_00_1_5_A_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766116","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-chpta2426b3-a-1-5-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}