{"product_id":"serpentin-devaporateur-goodman-chpta2426c3-a-1-5-a-2-tonnes","title":"GOODMAN CHPTA2426C3 Evaporator A-Coil | 1.5 to 2 Tons","description":"\u003ch2\u003eGoodman CHPTA2426C3: a 21 in high cabinet for 1.5 to 2 tons on a 26 in furnace\u003c\/h2\u003e\n\u003cp\u003eThree things to know about the \u003cstrong\u003eGoodman CHPTA2426C3 evaporator coil\u003c\/strong\u003e, before you even read the spec sheet. One: its nominal range covers 1.5 to 2 tons. Two: it is 26 in wide. Three: its cabinet is 21 in high, which sets it apart from its twin, the CHPTA2426B3. Everything else follows from these three facts.\u003c\/p\u003e\n\u003cp\u003eAirGreen installs it for homeowners in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, when the furnace has some height at the top of the plenum.\u003c\/p\u003e\n\n\u003ch3\u003eWhat an evaporator coil is for, in plain terms\u003c\/h3\u003e\n\u003cp\u003ePicture a car radiator working in reverse. Instead of getting rid of engine heat, it removes heat from the air in your home. Cold refrigerant flows through the copper tubes, the warm air from your rooms passes between the fins, and heat moves from one to the other. The cooled air returns to the vents, while the heat goes to the outdoor unit.\u003c\/p\u003e\n\u003cp\u003eThe CHPTA2426C3 is an A-coil: two sloped panels that meet at the top. The air rises through the centre and passes through both faces, which gives a large exchange surface in a compact volume. It comes in an insulated cabinet, ready to sit on the furnace.\u003c\/p\u003e\n\n\u003ch3\u003eWhy 21 in of height\u003c\/h3\u003e\n\u003cp\u003ePublished dimensions: 26 × 21 × 21 in. The extra height compared with the B3 gives a longer air path and a roomier cabinet where the air crosses the heat exchanger. For the homeowner, this means more ease during installation and maintenance, provided the space exists above the furnace.\u003c\/p\u003e\n\u003cp\u003eSo it is the available height, more than capacity, that guides the choice between the B3 and the C3. If the ceiling of your mechanical room is close to the plenum, the shorter cabinet of the B3 will make more sense. Otherwise, the C3 goes in without constraint. We measure with a tape, not by eye.\u003c\/p\u003e\n\n\u003ch3\u003eSpec sheet summary\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCHPTA2426C3, cased evaporator coil, CHPTA range;\u003c\/li\u003e\n\u003cli\u003enominal size: 1.5 to 2 tons, 24,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant and TXV metering device;\u003c\/li\u003e\n\u003cli\u003e3\/8 in liquid line, 7\/8 in suction line;\u003c\/li\u003e\n\u003cli\u003epublished position: horizontal;\u003c\/li\u003e\n\u003cli\u003eleak detection: R-32 refrigerant sensor, designed to last the life of the coil;\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty; online registration within 60 days of installation is not required in Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow an installation day unfolds\u003c\/h3\u003e\n\u003cp\u003eHere is what you can expect on the day, in the order things usually happen with us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ein the morning, the crew protects the floors, shuts off the power and opens the furnace plenum;\u003c\/li\u003e\n\u003cli\u003ethe cabinet goes in, with a custom-built insulated transition if the furnace width differs from 26 in;\u003c\/li\u003e\n\u003cli\u003eoutside, the unit is set on a stable base, then the copper piping is run and brazed;\u003c\/li\u003e\n\u003cli\u003ethe circuit is pressurized with nitrogen to look for leaks, then pulled into a vacuum;\u003c\/li\u003e\n\u003cli\u003ethe condensate drain and the thermostat are connected;\u003c\/li\u003e\n\u003cli\u003ethe system starts up, the airflow is adjusted, and a technician explains everything at your pace.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBefore that day, an estimate visit has already measured the furnace and checked the electrical panel. No surprise should show up that same morning.\u003c\/p\u003e\n\n\u003ch3\u003eMatching with the outdoor unit\u003c\/h3\u003e\n\u003cp\u003eThe coil does not work alone. It pairs with a Goodman outdoor unit of the same capacity and the same refrigerant, installed at the same time. This pair is identified by an AHRI number. It is this number, not the coil by itself, that carries the SEER2, EER2 and HSPF2 ratings. We confirm it in the directory before ordering.\u003c\/p\u003e\n\u003cp\u003eInformation checked on 2026-11-26: no R-32 match with this coil currently appears in the ENERGY STAR data. The AHRI directory remains the reference for the outdoor unit chosen.\u003c\/p\u003e\n\n\u003ch3\u003ePlacing the C3 in the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSame range, shorter cabinet\u003c\/strong\u003e: CHPTA2426B3;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSmaller\u003c\/strong\u003e: CHPTA1822A3 and CHPTA1822B3, for 1.5 ton and 22 in wide;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOne step up\u003c\/strong\u003e: CHPTA3026B3 and CHPTA3026C3, from 2 to 2.5 tons, still 26 in. The C3's footprint is found there unchanged, with more capacity;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e30 in width\u003c\/strong\u003e: CHPTA3630B3, CHPTA3630C3, CHPTA4230C3, CHPTA4830C3 and CHPTA6030D3, from 2.5 to 5 tons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll eleven models have the same R-32 and the same TXV. So you are comparing three parameters: capacity, width, height.\u003c\/p\u003e\n\n\u003ch3\u003eMaintenance: what the height makes easier\u003c\/h3\u003e\n\u003cp\u003eA coil does not demand much attention, but it must stay clean. Dust that gets through a worn-out filter settles on the fins and reduces airflow. A 21 in cabinet leaves a little more clearance to inspect the face of the coil and the pan that collects the condensation water.\u003c\/p\u003e\n\u003cp\u003eOur advice is to plan a yearly check, preferably in spring, before the air conditioning season. It includes inspecting the pan, checking the drain, the condition of the filter and a look at the connections. A preventive check is better than an overflowing pan in the middle of July.\u003c\/p\u003e\n\n\u003ch3\u003eHeating with a heat pump without throwing out the furnace\u003c\/h3\u003e\n\u003cp\u003eWhen the outdoor unit is a heat pump, the system heats in winter along the same path that cools in summer. The furnace is not shelved: it keeps its blower, its filters and its role as backup in very cold weather. We set with you the temperature threshold at which it takes over, so that the backup heat is used only when the heat pump is no longer enough.\u003c\/p\u003e\n\u003cp\u003eThe blower must still provide the system's airflow, which we check at the visit.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we check before quoting\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 requires an outdoor unit with the same refrigerant;\u003c\/li\u003e\n\u003cli\u003ethe published ratings apply only to the certified match;\u003c\/li\u003e\n\u003cli\u003ethe furnace width and the blower capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe company that installs it\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company established in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\n\u003ch3\u003eAbout the brand\u003c\/h3\u003e\n\u003cp\u003eGoodman is part of Daikin Comfort Technologies, alongside Daikin and Amana. The brand's R-32 coils go with new-generation central air conditioners and heat pumps, on a furnace or on a modular blower.\u003c\/p\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs assess the complete system, not the coil alone, and according to the installation date. We validate the match against the official list while preparing your quote, then explain what your project may qualify for.\u003c\/p\u003e\n\n\u003ch3\u003eHave your furnace measured\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402709627172,"sku":"CHPTA2426C3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CHPTA_CHPTA2426C3_00_1_5_A_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766116","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-chpta2426c3-a-1-5-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}