{"product_id":"serpentin-devaporateur-goodman-chpta3026b3-a-2-a-2-5-tonnes","title":"GOODMAN CHPTA3026B3 Evaporator A-Coil | 2 to 2.5 Tons","description":"\u003ch2\u003eQuestions and answers about the Goodman CHPTA3026B3 coil, 2 to 2.5 tons in a 26 in cabinet\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGoodman CHPTA3026B3 evaporator coil\u003c\/strong\u003e is mostly of interest to owners of bungalows, compact cottages and semi-detached homes that have a mid-width furnace but a more serious cooling load than average. Rather than a dry spec sheet, here are the questions that customers in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e ask us most often about it.\u003c\/p\u003e\n\n\u003ch3\u003eWhat exactly is this product?\u003c\/h3\u003e\n\u003cp\u003eA cased A-coil from the CHPTA range, using R-32 refrigerant. It sits in the furnace plenum and receives refrigerant from the outdoor unit. Its nominal range runs from 2 to 2.5 tons, or 30,000 BTU\/h, and it measures 26 × 17-1\/2 × 21 in. The metering device is a TXV.\u003c\/p\u003e\n\n\u003ch3\u003eWhy 26 in of width for a capacity of 2 to 2.5 tons?\u003c\/h3\u003e\n\u003cp\u003eThat is the particularity of this model. For the same 26 in width, the series offers two ranges: 1.5 to 2 tons with the CHPTA2426B3, 2 to 2.5 tons here. The footprint is identical, which means a 26 in furnace can take either one. Only the load calculation will say which one fits.\u003c\/p\u003e\n\u003cp\u003eAlso, the suction line is 7\/8 in on both, and the liquid line 3\/8 in. The difference therefore lies in the exchange surface and in the planned match with the outdoor unit, not in the size.\u003c\/p\u003e\n\n\u003ch3\u003eHow many tons does my home need?\u003c\/h3\u003e\n\u003cp\u003eNo reliable rule fits in one line. Living area, ceiling height, insulation quality, window size and orientation, a finished basement, all of it shifts the result. We run the load calculation on site. If the figure falls in the 2 to 2.5 ton zone, this coil comes into play.\u003c\/p\u003e\n\u003cp\u003eAnd what if a unit that is too big were proposed? The system would start short-cycling, cool the air without time to remove the humidity, and leave the house sticky. That is why we prefer a right-sized system to a generous one.\u003c\/p\u003e\n\n\u003ch3\u003eDoes it heat too?\u003c\/h3\u003e\n\u003cp\u003eOnly with a heat pump as the outdoor unit. In that case, the coil delivers heat to the air in your home in winter, and the same appliance serves both seasons. With a central air conditioner, it only provides cooling. The furnace stays in place, with its blower, its filters and its role as relay in very cold weather, below a threshold that we program with you.\u003c\/p\u003e\n\n\u003ch3\u003eCan we keep the old air conditioner?\u003c\/h3\u003e\n\u003cp\u003eGenerally, no. The CHPTA3026B3 runs on R-32 and must pair with the outdoor unit specified by the manufacturer, of the same capacity. So we install the complete system, coil and unit together. We also confirm the match's AHRI number in the directory before the order, because the SEER2, EER2 and HSPF2 ratings belong to the system, not to the coil alone.\u003c\/p\u003e\n\u003cp\u003eAs of 2026-11-26, no R-32 match with this coil was listed in the ENERGY STAR data set; AHRI serves as the reference.\u003c\/p\u003e\n\n\u003ch3\u003eB3 or C3?\u003c\/h3\u003e\n\u003cp\u003eThe CHPTA3026C3 has the same capacity, the same width and the same R-32, but a taller cabinet. If your mechanical room is low, the B3 is the one to pick. If the plenum has room, the C3 is possible. In both cases, we measure before answering.\u003c\/p\u003e\n\n\u003ch3\u003eDoes a finished basement change the choice?\u003c\/h3\u003e\n\u003cp\u003eOften, yes. A finished basement adds volume to cool and, sometimes, rooms whose air vents are far from the furnace. In that case, capacity alone is not enough: the duct network also has to let enough air through. We look at the existing ducts, spot the pinched sections and tell you frankly whether a fix is needed before installation.\u003c\/p\u003e\n\u003cp\u003eConversely, a home whose upper floor gets very hot in summer, but whose ground floor stays cool, responds well to a carefully sized system and good airflow balancing. The coil is only one link: it is the whole system that delivers comfort.\u003c\/p\u003e\n\n\u003ch3\u003eAnd compared with the other sizes?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSmaller, same width\u003c\/strong\u003e: CHPTA2426B3 and CHPTA2426C3, from 1.5 to 2 tons;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSmaller and narrower\u003c\/strong\u003e: CHPTA1822A3 and CHPTA1822B3, at 1.5 ton, on 22 in;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLarger and wider\u003c\/strong\u003e: CHPTA3630B3 and CHPTA3630C3, from 2.5 to 3 tons, on 30 in, then CHPTA4230C3, from 2.5 to 3.5 tons;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eThe large sizes\u003c\/strong\u003e: CHPTA4830C3 (3.5 to 4 tons) and CHPTA6030D3 (4 to 5 tons).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFull spec sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: CHPTA3026B3;\u003c\/li\u003e\n\u003cli\u003etype: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003enominal size: 2 to 2.5 tons (30,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-32;\u003c\/li\u003e\n\u003cli\u003edimensions W × H × D: 26 × 17-1\/2 × 21 in;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid, 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003emetering device: TXV;\u003c\/li\u003e\n\u003cli\u003eposition: horizontal;\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant sensor designed to last the life of the coil;\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty, online registration within 60 days of installation (not required in Quebec).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow long does it take to get used to?\u003c\/h3\u003e\n\u003cp\u003eNot long. After start-up, the thermostat replaces the window air conditioners and the extra fans. The rooms even out, the air is drier, and you stop wondering which bedroom will be bearable at nightfall. For winter, a heat pump changes the dynamic of the bill: it moves heat rather than making it, which gives, in mild weather, two to three times more heat than the electricity consumed.\u003c\/p\u003e\n\n\u003ch3\u003eOur installation, step by step\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. On this project, we:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003etake the furnace measurements and check the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstall the cabinet in the plenum, with an insulated transition if the width differs, and seal the joints;\u003c\/li\u003e\n\u003cli\u003einstall the outdoor unit, braze the piping, test the circuit with nitrogen and pull a vacuum;\u003c\/li\u003e\n\u003cli\u003econnect the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003estart the system, adjust the airflow and explain how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eThree checks before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 requires an outdoor unit with the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe published ratings belong to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe furnace must have the right width and a blower with the required airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA word about Goodman\u003c\/h3\u003e\n\u003cp\u003eThe brand belongs to Daikin Comfort Technologies, which also produces Daikin and Amana. Its R-32 coils equip recent central air conditioners and heat pumps, on a furnace or on a modular blower.\u003c\/p\u003e\n\n\u003ch3\u003eAnd the incentives?\u003c\/h3\u003e\n\u003cp\u003eEligibility for Hydro-Québec programs concerns the complete system, according to the installation date, and not the coil by itself. We consult the official list while preparing your quote and tell you what applies.\u003c\/p\u003e\n\n\u003ch3\u003eNext step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402711134500,"sku":"CHPTA3026B3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CHPTA_CHPTA3026B3_00_2_A_2_5_TONNES_30000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766116","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-chpta3026b3-a-2-a-2-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}