{"product_id":"serpentin-devaporateur-goodman-chpta3026c3-a-2-a-2-5-tonnes","title":"GOODMAN CHPTA3026C3 Evaporator A-Coil | 2 to 2.5 Tons","description":"\u003ch2\u003eReplacing an old central air conditioner: the Goodman CHPTA3026C3, 2 to 2.5 tons, 21 in cabinet\u003c\/h2\u003e\n\u003cp\u003eMany of our customers are not starting from zero. They already have a central air conditioner that has had its day: a tired compressor, a clogged coil, a refrigerant from a bygone generation. They want to replace it without redoing their ductwork. The \u003cstrong\u003eGoodman CHPTA3026C3 evaporator coil\u003c\/strong\u003e was designed for this scenario: 2 to 2.5 tons (30,000 BTU\/h), 26 in wide, 21 in high, using R-32 refrigerant.\u003c\/p\u003e\n\u003cp\u003eHere is how such a replacement goes with us, in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eFirst visit: we look, we measure, we listen\u003c\/h3\u003e\n\u003cp\u003eWe come to your home to look at what is there. Which furnace? What plenum width? Where does the drain run? Does the electrical panel have room for the outdoor unit's circuit? We measure the top of the furnace because this coil, with its 21 in height and its 26 in width, needs a bit of vertical space. If that space is missing, we will propose the CHPTA3026B3 instead, with the same capacity and a shorter cabinet.\u003c\/p\u003e\n\u003cp\u003eWe also run the load calculation. It is what says whether 2 tons or 2.5 tons suits your home, not the age or size of the old unit. An old air conditioner was sometimes too big, sometimes too small: copying it without checking would only repeat the mistake.\u003c\/p\u003e\n\n\u003ch3\u003eSecond step: the written quote\u003c\/h3\u003e\n\u003cp\u003eYou receive a clear document: the coil, the matched outdoor unit, the AHRI number of the pair, what is included in the installation, what is not. We also indicate whether the Hydro-Québec program list may apply, depending on the installation date.\u003c\/p\u003e\n\u003cp\u003eThe coil has no efficiency rating of its own. The SEER2, EER2 and HSPF2 ratings belong to the matched system, hence the importance of the AHRI number. As of 2026-11-26, no R-32 match with this model was listed in the ENERGY STAR data consulted.\u003c\/p\u003e\n\n\u003ch3\u003eThird step: the installation\u003c\/h3\u003e\n\u003cp\u003eThe cabinet goes on the furnace, with an insulated transition built on site if the width does not match 26 in. The outdoor unit is set on its base, the piping is brazed, and the circuit is pressure-tested with nitrogen and pulled into a vacuum. Finally the drain and the thermostat are connected, then we start up and adjust the airflow.\u003c\/p\u003e\n\n\u003ch3\u003eWhat a new coil corrects\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ea clean heat exchanger, without the crushed fins or the fouling of an old model;\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant and a leak sensor designed to last the life of the coil;\u003c\/li\u003e\n\u003cli\u003ea TXV metering device, which regulates the refrigerant flow in the heat exchanger;\u003c\/li\u003e\n\u003cli\u003ean insulated cabinet, which limits condensation on the walls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCHPTA3026C3 spec sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil, CHPTA range;\u003c\/li\u003e\n\u003cli\u003enominal size: 2 to 2.5 tons (30,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003edimensions W × H × D: 26 × 21 × 21 in;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in for liquid and 7\/8 in for suction;\u003c\/li\u003e\n\u003cli\u003epublished installation position: horizontal;\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty; online registration within 60 days of installation, not required in Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCan the old outdoor unit be reused?\u003c\/h3\u003e\n\u003cp\u003eNo, as a general rule. An R-32 coil pairs with an outdoor unit of the same refrigerant and the same capacity, installed at the same time. Hooking a new coil to an old compressor is not a saving: you lose the certified match and the ratings that go with it.\u003c\/p\u003e\n\n\u003ch3\u003eWhat you will feel after the replacement\u003c\/h3\u003e\n\u003cp\u003eThe most visible difference is not always the temperature. It is the humidity. A system with a clean coil and well-chosen capacity removes water from the air while it cools: the sheets no longer stick, the basement stops smelling stale and the wooden door no longer swells in August. The house feels cool at a higher setpoint, which leaves room to save.\u003c\/p\u003e\n\u003cp\u003eThe second change is sound. A system that runs for a long time at moderate speed is less noticeable than an old model that starts abruptly, then shuts off, then starts again. People often tell us they only notice the system when they come home and feel how pleasant it is.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently asked questions about replacement\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo the ducts have to be redone?\u003c\/strong\u003e Generally not. We inspect the existing network and point out any sections to fix before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill my electrical panel be enough?\u003c\/strong\u003e We check it at the first visit, because the outdoor unit needs its own circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat if my furnace has a width other than 26 in?\u003c\/strong\u003e We build an insulated transition on site.\u003c\/p\u003e\n\n\u003ch3\u003eWhere this model sits in the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCHPTA3026B3\u003c\/strong\u003e: same range, width and metering device; shorter cabinet;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCHPTA2426B3 and CHPTA2426C3\u003c\/strong\u003e: same width, range of 1.5 to 2 tons;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCHPTA3630B3 and CHPTA3630C3\u003c\/strong\u003e: 2.5 to 3 tons on 30 in, for wider furnaces;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCHPTA1822A3 and CHPTA1822B3\u003c\/strong\u003e: 1.5 ton on 22 in;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCHPTA4230C3, CHPTA4830C3 and CHPTA6030D3\u003c\/strong\u003e: from 2.5 up to 5 tons, on 30 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat becomes of the furnace\u003c\/h3\u003e\n\u003cp\u003eIt stays right there. If you choose a heat pump, the coil will also heat in winter and the furnace will take over only below the temperature threshold programmed with you. With an air conditioner, it keeps its usual heating role. In every case, the blower must be able to provide the system's airflow, a point we check from the first visit.\u003c\/p\u003e\n\n\u003ch3\u003eWhy replace now rather than wait for a breakdown\u003c\/h3\u003e\n\u003cp\u003eA breakdown almost always comes at the worst time: the first heat wave, when every installer is swamped. Replacing the system in spring or fall leaves time to compare, plan and check the incentive programs without pressure. We far prefer installing a well-chosen system to making an emergency repair.\u003c\/p\u003e\n\n\u003ch3\u003eAbout AirGreen\u003c\/h3\u003e\n\u003cp\u003eA family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company established in Montreal for more than fifteen years, AirGreen carries out its refrigeration, ventilation and electrical work under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\n\u003ch3\u003eTo check before replacing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 requires an outdoor unit with the same refrigerant.\u003c\/li\u003e\n\u003cli\u003eThe ratings apply to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe furnace width, the plenum height and the blower must be suitable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe Goodman brand\u003c\/h3\u003e\n\u003cp\u003eGoodman is part of Daikin Comfort Technologies, like Daikin and Amana. Its R-32 coils install on a furnace or on a modular blower.\u003c\/p\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs cover the complete system. We validate the match against the official list at the time of the quote, according to the installation date, then tell you what applies in your case.\u003c\/p\u003e\n\n\u003ch3\u003ePlan your replacement\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402711888164,"sku":"CHPTA3026C3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CHPTA_CHPTA3026C3_00_2_A_2_5_TONNES_30000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766116","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-chpta3026c3-a-2-a-2-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}