{"product_id":"serpentin-devaporateur-goodman-chpta3630c3-a-2-5-a-3-tonnes","title":"GOODMAN CHPTA3630C3 Evaporator A-Coil | 2.5 to 3 Tons","description":"\u003ch2\u003eA year with the Goodman CHPTA3630C3: 2.5 to 3 tons, 30 in wide, 21 in cabinet\u003c\/h2\u003e\n\u003cp\u003eA coil is judged over twelve months, not on a spec sheet. Here, season by season, is what the \u003cstrong\u003eGoodman CHPTA3630C3 evaporator coil\u003c\/strong\u003e does in a home in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e or on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, once it is installed on the furnace and matched with a Goodman outdoor unit of the same capacity.\u003c\/p\u003e\n\n\u003ch3\u003eSpring: the start-up\u003c\/h3\u003e\n\u003cp\u003eThis is the best time to install. Schedules are more flexible, temperatures let us shut off the heat without discomfort, and you have time to compare. We measure the furnace, check the electrical panel, then install the 30 × 21 × 21 in cabinet (width, height, depth). This 21 in height calls for a clear plenum; if space is too tight, the CHPTA3630B3, with the same range but a shorter cabinet, settles the question.\u003c\/p\u003e\n\u003cp\u003eThe outdoor unit is set, the piping is brazed, and the circuit is pressure-tested with nitrogen and then pulled into a vacuum. The drain and the thermostat are connected. We start up, adjust the airflow and explain how it works.\u003c\/p\u003e\n\n\u003ch3\u003eSummer: the coil at work\u003c\/h3\u003e\n\u003cp\u003eR-32 refrigerant flows through the tubes, passes through the TXV and evaporates in the fins. The air in the house, pushed by the blower, gives up its heat and its humidity. The water runs into the pan and then to the drain. Upstairs, the air is cool; in the basement, it is dry.\u003c\/p\u003e\n\u003cp\u003eThe 2.5 to 3 ton size (36,000 BTU\/h) suits homes big enough to justify a generous central system, without sliding into oversizing. An oversized system short-cycles and leaves the humidity in place: so we size it as closely as possible, based on your home's actual load.\u003c\/p\u003e\n\n\u003ch3\u003eFall: inspection time\u003c\/h3\u003e\n\u003cp\u003eBefore the cold, we clean. A glance at the filter, a check of the drain, an inspection of the pan. If your outdoor unit is a heat pump, we check that nothing is blocking its fins (leaves, branches). This routine is simple and extends the life of the system.\u003c\/p\u003e\n\u003cp\u003eIt is also the time when we set with you the outdoor temperature threshold below which the furnace will take over from the heat pump. This setting determines the split between electric or backup heat and the heat coming from the heat pump.\u003c\/p\u003e\n\n\u003ch3\u003eWinter: if the outdoor unit is a heat pump\u003c\/h3\u003e\n\u003cp\u003eThe cycle reverses: the refrigerant captures heat outdoors, even in cold weather, and delivers it to the air in the house through the coil. A heat pump moves heat rather than making it; at mild temperatures, it provides two to three times more heat than the electricity it consumes, and this ratio declines as the cold deepens. In the coldest weather, the furnace takes over, with its blower and its filters.\u003c\/p\u003e\n\n\u003ch3\u003eFive questions to ask any installer\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eWhat is the AHRI number of the proposed match, and can it be checked in the directory?\u003c\/li\u003e\n\u003cli\u003eHas the load calculation for my home been done, or was the capacity guessed?\u003c\/li\u003e\n\u003cli\u003eWho checks the blower airflow and the condition of the ducts?\u003c\/li\u003e\n\u003cli\u003eIs the circuit pressure-tested with nitrogen and pulled into a vacuum before start-up?\u003c\/li\u003e\n\u003cli\u003eWho takes care of checking my eligibility for incentives, according to the installation date?\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eWe are comfortable answering these five questions. If an installer does not answer them, that is a signal to take seriously.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: CHPTA3630C3, cased evaporator coil, CHPTA range;\u003c\/li\u003e\n\u003cli\u003enominal size: 2.5 to 3 tons (36,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-32;\u003c\/li\u003e\n\u003cli\u003emetering device: TXV;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid, 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003epublished position: horizontal;\u003c\/li\u003e\n\u003cli\u003eleak detection: R-32 refrigerant sensor designed to last the life of the coil;\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty, online registration within 60 days of installation (not required in Quebec).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe AHRI number, the real judge of efficiency\u003c\/h3\u003e\n\u003cp\u003eThis coil carries no efficiency rating by itself. SEER2, EER2 and HSPF2 relate to a complete system, identified by an AHRI number that links a specific coil and a specific outdoor unit. We confirm it before the order. When we checked on 2026-11-26, no R-32 match with this model was listed in the ENERGY STAR data set.\u003c\/p\u003e\n\n\u003ch3\u003eWhere it sits in the range\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eTwin brother, shorter cabinet\u003c\/strong\u003e: CHPTA3630B3;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eA bit more capacity on the same width and the same height\u003c\/strong\u003e: CHPTA4230C3, from 2.5 to 3.5 tons;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNarrower\u003c\/strong\u003e: CHPTA3026B3 and CHPTA3026C3, from 2 to 2.5 tons, on 26 in;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMuch larger\u003c\/strong\u003e: CHPTA4830C3 and CHPTA6030D3, from 3.5 to 5 tons;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSmaller\u003c\/strong\u003e: CHPTA1822A3, CHPTA1822B3, CHPTA2426B3 and CHPTA2426C3.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat we do at your home\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company established in Montreal for more than fifteen years. We work under RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. The installation includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, and checking the blower and the panel;\u003c\/li\u003e\n\u003cli\u003ethe cabinet in the plenum, with a transition built if needed, and sealing the joints;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit, brazed piping, nitrogen test and vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning and explanations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eNotes before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 refrigerant: the outdoor unit must be of the same type and installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe furnace must be 30 in wide and have a blower capable of the airflow required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhen the 21 in height makes the difference\u003c\/h3\u003e\n\u003cp\u003eIn a home where the supply plenum is wide and tall, this cabinet fits in naturally. The air path above the fins is longer, the transition to the ducts is gentler, and access to the pan for maintenance is easier. In a narrow mechanical room, the same height can become an obstacle. Hence the importance of the measurement taken before the order.\u003c\/p\u003e\n\n\u003ch3\u003eThe manufacturer\u003c\/h3\u003e\n\u003cp\u003eGoodman is a member of Daikin Comfort Technologies, just like Daikin and Amana. Its R-32 coils go with new-generation heat pumps and central air conditioners, on a furnace or a modular blower.\u003c\/p\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eEligibility for Hydro-Québec programs depends on the complete system and the installation date, not on the coil alone. We check the official list during the quote and spell out what applies.\u003c\/p\u003e\n\n\u003ch3\u003eBook your visit\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402715197732,"sku":"CHPTA3630C3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CHPTA_CHPTA3630C3_00_2_5_A_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766117","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-chpta3630c3-a-2-5-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}