{"product_id":"serpentin-devaporateur-goodman-chpta4230c3-a-2-5-a-3-5-tonnes","title":"GOODMAN CHPTA4230C3 Evaporator A-Coil | 2.5 to 3.5 Tons","description":"\u003ch2\u003eCHPTA4230C3: the wide-range Goodman coil, from 2.5 to 3.5 tons on 30 in\u003c\/h2\u003e\n\u003cp\u003eMost coils in the series cover half a ton or one ton. The \u003cstrong\u003eGoodman CHPTA4230C3 evaporator coil\u003c\/strong\u003e spans a full ton, from 2.5 to 3.5 tons (42,000 BTU\/h nominal). This range overlaps that of the CHPTA3630B3 and CHPTA3630C3 on one side, and that of the CHPTA4830C3 on the other. It therefore serves as a pivot for homes whose load does not fit neatly into one box.\u003c\/p\u003e\n\u003cp\u003eWe install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. Its footprint is 30 × 21 × 21 in, with R-32 and the TXV.\u003c\/p\u003e\n\n\u003ch3\u003eThe overlap, explained with a mental chart\u003c\/h3\u003e\n\u003cp\u003ePicture the series on an axis, from the smallest range to the largest:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCHPTA3630B3 and CHPTA3630C3: from 2.5 to 3 tons;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCHPTA4230C3: from 2.5 to 3.5 tons\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003eCHPTA4830C3: from 3.5 to 4 tons;\u003c\/li\u003e\n\u003cli\u003eCHPTA6030D3: from 4 to 5 tons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYour home may fall into several ranges at once. A 3 ton load, for example, is covered by the first three models on the list. In that case, capacity is no longer the deciding criterion; it is the available height, the preferred match with the outdoor unit and the margin you want to have for the future.\u003c\/p\u003e\n\n\u003ch3\u003eWhen to choose the 4230 over the 3630\u003c\/h3\u003e\n\u003cp\u003eChoose the CHPTA4230C3 when the calculated load approaches the top of the 3 ton bracket, when an addition is planned (a basement being finished, an extra floor, a sunroom), or when you want some leeway for summers that are getting hotter. The footprint is identical to that of the CHPTA3630C3: same 30 in width, same 21 in height, same depth. The larger range comes from a different exchange surface and match, not from a bigger cabinet.\u003c\/p\u003e\n\u003cp\u003eStay with the 3630 if the load is clearly under 3 tons. A system bigger than necessary brings no extra comfort; it short-cycles and leaves the humidity.\u003c\/p\u003e\n\n\u003ch3\u003eWhen the 4830 becomes more reasonable\u003c\/h3\u003e\n\u003cp\u003eIf the load calculation exceeds 3.5 tons, this coil reaches its limit. The CHPTA4830C3 then takes over, with a range of 3.5 to 4 tons on the same 30 in width. We never force a coil to work beyond its nominal range. The opposite is true too: we do not propose this model simply because its range looks more reassuring.\u003c\/p\u003e\n\n\u003ch3\u003eAn enlarged home: an example\u003c\/h3\u003e\n\u003cp\u003eA couple in Longueuil bought a bungalow, then added a back room and finished the basement. Their old air conditioner, sized for the original house, can no longer keep up. The load calculation, redone after the work, falls in the upper part of this coil's range. A more modest model would have run continuously on heat wave days; a clearly bigger one would have short-cycled. The CHPTA4230C3, with the right outdoor unit, offers the right balance.\u003c\/p\u003e\n\u003cp\u003eThe lesson is simple: redo the load calculation whenever the home changes. A replaced window, an insulated attic, an added room all change the needs, sometimes in one direction and sometimes in the other.\u003c\/p\u003e\n\n\u003ch3\u003eCHPTA4230C3 spec sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil, CHPTA range, A shape;\u003c\/li\u003e\n\u003cli\u003enominal size: 2.5 to 3.5 tons (42,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-32; metering device: TXV;\u003c\/li\u003e\n\u003cli\u003edimensions W × H × D: 30 × 21 × 21 in;\u003c\/li\u003e\n\u003cli\u003eliquid connection: 3\/8 in; suction: 7\/8 in;\u003c\/li\u003e\n\u003cli\u003epublished installation position: horizontal;\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant sensor designed to last the life of the coil;\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty, online registration within 60 days of installation (not required in Quebec).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow the outdoor unit is chosen\u003c\/h3\u003e\n\u003cp\u003eThe coil pairs with a Goodman outdoor unit of the same capacity and the same refrigerant. Because its range is wide, several outdoor units may suit it; each forms a different certified system with it, with its own AHRI number and its own SEER2, EER2 and HSPF2 ratings. The coil itself has no efficiency rating of its own.\u003c\/p\u003e\n\u003cp\u003eOur job is to select the unit that matches the calculated load, then confirm the AHRI number in the directory. As of 2026-11-26, the ENERGY STAR data set showed no R-32 match with this coil; AHRI therefore remains the reference.\u003c\/p\u003e\n\n\u003ch3\u003eHeat pump warmth and the furnace's role\u003c\/h3\u003e\n\u003cp\u003eWith a heat pump, the coil heats in winter, through the same ducts that serve the air conditioning. The furnace keeps its role: it takes over below the temperature threshold that we program with you. A heat pump moves heat instead of creating it, which allows it to supply, in mild weather, two to three times more heat than the electricity consumed. Its performance declines as the cold intensifies, hence the usefulness of the backup.\u003c\/p\u003e\n\u003cp\u003eFor a system this size, the blower must provide a considerable airflow. We check it carefully and, if it is not up to it, we tell you before you sign.\u003c\/p\u003e\n\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company, established in Montreal for more than fifteen years and holding RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. Our installation includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace and plenum, and checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the cabinet, with an insulated transition if needed, and sealing the duct joints;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit, brazed piping, nitrogen test and vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and the walk-through.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eBefore ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 requires an outdoor unit with the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified match, not to the coil alone.\u003c\/li\u003e\n\u003cli\u003eThe furnace must be 30 in wide and have a suitable blower.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAbout Goodman\u003c\/h3\u003e\n\u003cp\u003eThe brand is part of Daikin Comfort Technologies, with Daikin and Amana. Its R-32 coils equip recent central systems, on a furnace or on a modular blower.\u003c\/p\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs apply to the complete system, according to the installation date, not to the coil alone. We check the official list at the time of the quote, then indicate what concerns your project.\u003c\/p\u003e\n\n\u003ch3\u003eReceive your quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402716016932,"sku":"CHPTA4230C3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CHPTA_CHPTA4230C3_00_2_5_A_3_5_TONNES_42000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766118","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-chpta4230c3-a-2-5-a-3-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}