{"product_id":"serpentin-devaporateur-goodman-chpta4830c3-a-3-5-a-4-tonnes","title":"GOODMAN CHPTA4830C3 Evaporator A-Coil | 3.5 to 4 Tons","description":"\u003ch2\u003eGoodman CHPTA4830C3: 3.5 to 4 tons for large homes, with a checklist to follow in order\u003c\/h2\u003e\n\u003cp\u003eWhen a home calls for 3.5 to 4 tons of cooling, the temptation is to look at the coil first. Our experience says the opposite: the coil comes last. Before it, four things have to be validated. The \u003cstrong\u003eGoodman CHPTA4830C3 evaporator coil\u003c\/strong\u003e (48,000 BTU\/h nominal, 30 in wide, 21 in high cabinet, R-32) then takes its logical place in a well-prepared project.\u003c\/p\u003e\n\u003cp\u003eWe carry out these projects in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, mostly in large homes, properties with finished basements and residences enlarged over the years.\u003c\/p\u003e\n\n\u003ch3\u003ePriority number one: the load calculation\u003c\/h3\u003e\n\u003cp\u003eAt this size, an error of half a ton is costly, in either direction. We calculate the load room by room: glazed areas, insulation, exposure, volumes. If the result exceeds this coil's range, we propose the CHPTA6030D3. If it falls lower, the CHPTA4230C3 becomes a serious option.\u003c\/p\u003e\n\n\u003ch3\u003ePriority number two: the electrical entrance\u003c\/h3\u003e\n\u003cp\u003eThe matched outdoor unit needs its own circuit. In a large home, the panel is sometimes already well occupied: dryer, stove, water heater, charging station. We examine the panel at the first visit and honestly tell you whether an upgrade is required. Our electrical work is done under our own licence.\u003c\/p\u003e\n\n\u003ch3\u003ePriority number three: the air network\u003c\/h3\u003e\n\u003cp\u003eA coil of this capacity demands a lot of air. If the ducts are too small or the returns insufficient, the system does not deliver what it promises. We inspect the network and the blower, and determine whether the airflow is up to the task. This point often decides the success of a large project.\u003c\/p\u003e\n\n\u003ch3\u003ePriority number four: the height above the furnace\u003c\/h3\u003e\n\u003cp\u003eThe CHPTA4830C3 footprint is 30 × 21 × 21 in. This cabinet must find its place in the plenum, with enough clearance. We measure before the order, which avoids surprises on installation day.\u003c\/p\u003e\n\n\u003ch3\u003eAnd finally, the coil\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: CHPTA4830C3, cased evaporator coil, CHPTA range, A-coil;\u003c\/li\u003e\n\u003cli\u003enominal size: 3.5 to 4 tons (48,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-32, TXV metering device;\u003c\/li\u003e\n\u003cli\u003edimensions W × H × D: 30 × 21 × 21 in;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid, 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003eposition published by the manufacturer: horizontal;\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant sensor designed to last the life of the coil;\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty, online registration within 60 days of installation (not required in Quebec).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat a system this size changes in daily life\u003c\/h3\u003e\n\u003cp\u003eIn a large home, air takes time to circulate from one end to the other. The system must therefore work for long periods, at moderate speed, to avoid differences between rooms. Good vent balancing, a well-placed thermostat and a clean filter count as much as the coil itself.\u003c\/p\u003e\n\u003cp\u003eHumidity is the other issue. A finished basement, an open kitchen, several bathrooms: in summer, the air holds a lot of water. A correctly sized coil removes it continuously, and the pan directs it to the drain. We check that this drain has the right slope and clearance, because it must carry away a significant flow of water.\u003c\/p\u003e\n\n\u003ch3\u003ePositioning yourself in the series\u003c\/h3\u003e\n\u003cp\u003eThe CHPTA4830C3 sits on the second-to-last step:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ebelow it, the CHPTA4230C3 (2.5 to 3.5 tons) and the CHPTA3630B3 and CHPTA3630C3 (2.5 to 3 tons) share its 30 in width;\u003c\/li\u003e\n\u003cli\u003eabove it, the CHPTA6030D3 (4 to 5 tons) offers the largest capacity in the series;\u003c\/li\u003e\n\u003cli\u003enarrower and smaller: the CHPTA3026B3 and CHPTA3026C3 (2 to 2.5 tons, 26 in), the CHPTA2426B3 and CHPTA2426C3 (1.5 to 2 tons, 26 in), then the CHPTA1822A3 and CHPTA1822B3 (1.5 ton, 22 in).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll share R-32 and the TXV. Here, the only 3.5 to 4 ton model is this C3: there is no variant with a shorter cabinet.\u003c\/p\u003e\n\n\u003ch3\u003eOne large system or two smaller ones?\u003c\/h3\u003e\n\u003cp\u003eIn some large homes, two more modest systems, one per floor or zone, give better comfort than a single big unit. In others, a single system is simpler and less costly. We discuss this option without bias, because we want your installation to be well suited, not just to carry a big number.\u003c\/p\u003e\n\n\u003ch3\u003eThe certified match\u003c\/h3\u003e\n\u003cp\u003eThe CHPTA4830C3 pairs with a Goodman outdoor unit of the same capacity and the same refrigerant. The SEER2, EER2 and HSPF2 ratings belong to the system and are tied to an AHRI number; the coil has no rating of its own. As of 2026-11-26, we found no R-32 match with this coil in the ENERGY STAR data; we therefore confirm the number in the AHRI directory before committing to the order.\u003c\/p\u003e\n\n\u003ch3\u003ePlanning the job\u003c\/h3\u003e\n\u003cp\u003eA project of this size is prepared. We set a date with you, plan access to the basement and to the yard for the outdoor unit, protect the floors and announce power shutoffs in advance. The goal is for installation day to run without improvisation, from the first connection to the final walk-through.\u003c\/p\u003e\n\n\u003ch3\u003eBackup heat and heat pump\u003c\/h3\u003e\n\u003cp\u003eWith a heat pump, the furnace stays useful: it takes over when the outdoor temperature falls below the threshold that we program with you. In mild weather, the heat pump provides two to three times more heat than the electricity it consumes.\u003c\/p\u003e\n\n\u003ch3\u003eOur installation\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company established in Montreal for more than fifteen years, under RBQ licence 5645-9605-01 (refrigeration, ventilation, electrical). We provide:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, and checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the cabinet in the plenum, the insulated transition if needed, sealing the duct joints;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit on a base or stand, brazed piping, nitrogen test and vacuum;\u003c\/li\u003e\n\u003cli\u003ethe condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment, the explanation at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eReminder of the points to confirm\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-32: the outdoor unit uses the same refrigerant and is installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified match.\u003c\/li\u003e\n\u003cli\u003eA 30 in wide furnace and a blower with the required airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe brand\u003c\/h3\u003e\n\u003cp\u003eGoodman is part of Daikin Comfort Technologies, like Daikin and Amana. Its R-32 coils install on a furnace or on a modular blower.\u003c\/p\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eEligibility for Hydro-Québec programs depends on the complete system, according to the installation date. We consult the official list at the time of the quote and tell you what applies.\u003c\/p\u003e\n\n\u003ch3\u003eGet your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Goodman","offers":[{"title":"Default Title","offer_id":68402717098276,"sku":"CHPTA4830C3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GOODMAN_CHPTA_CHPTA4830C3_00_3_5_A_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766117","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-goodman-chpta4830c3-a-3-5-a-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}