{"product_id":"serpentin-devaporateur-gree-fxa48c32ah-a-4-tonnes","title":"GREE FXA48C32AH Evaporator A-Coil | 4 Tons","description":"\u003ch2\u003eFXA48C32AH: a 4-ton Gree coil, 24-1\/2 in wide, for multi-storey homes\u003c\/h2\u003e\n\u003cp\u003eWhen a home has an upper floor, a finished basement and maybe an addition built later, the furnace has to move a lot of air. The \u003cstrong\u003eGree FXA48C32AH evaporator coil\u003c\/strong\u003e is designed for that kind of building: 4 tons (48,000 BTU\/h), A-shaped, insulated cabinet, R-32 refrigerant. It sits on your furnace and, paired with a Gree outdoor unit of the same capacity, it cools and, with a heat pump, it heats.\u003c\/p\u003e\n\u003cp\u003eAirGreen installs it in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eWidth, the first thing to confirm\u003c\/h3\u003e\n\u003cp\u003eAt 24-1\/2 in, this coil is wider than the 2-ton and 3-ton models in the series, which measure 17-1\/2 in. Its cabinet is 24-1\/2 in wide, 28-1\/2 in high and 21-1\/4 in deep, and it weighs 110 lb. These dimensions are not a detail: the cabinet has to line up with the furnace opening.\u003c\/p\u003e\n\u003cp\u003eWhen the furnace is narrower, we do not force anything. We build and insulate a transition on site. When it is already the right width, the installation is direct. In every case, we measure before ordering, not after.\u003c\/p\u003e\n\n\u003ch3\u003eThe pairing: a step we do not rush\u003c\/h3\u003e\n\u003cp\u003eFor this model, the sheet carries no AHRI number of its own. The FXA48C32AH is paired with a Gree outdoor unit of the same capacity and the same refrigerant, and we validate the exact combination, along with its AHRI number, before placing the order. Why this precaution? Because efficiency ratings live at the system level, and the only way to know what you will get is to check the directory for the chosen pair.\u003c\/p\u003e\n\u003cp\u003eSo do not trust a quote that promises ratings without naming the outdoor unit or the certification number: only complete systems can be compared.\u003c\/p\u003e\n\n\u003ch3\u003eAirflow: the reason for the large size\u003c\/h3\u003e\n\u003cp\u003eA 4-ton coil needs a lot of air through its fins. If the blower does not deliver enough, two things can happen: the coil frosts over, or the far rooms do not get cool enough. So we check the blower and the condition of the ducts during the visit, and we set the airflow at commissioning.\u003c\/p\u003e\n\u003cp\u003eThat is the difference between equipment that \"works\" and equipment that makes the house comfortable, floor after floor.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the coil really does\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIt receives refrigerant from the outdoor unit in its tubes.\u003c\/li\u003e\n\u003cli\u003eIn summer, the refrigerant evaporates, picks up heat from the air passing through the coil and cools the house; the moisture condenses and runs off through the drain.\u003c\/li\u003e\n\u003cli\u003eIn winter, with a heat pump, the cycle reverses and the air is warmed in the same ducts.\u003c\/li\u003e\n\u003cli\u003eWith a central air conditioner, it is limited to cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: FXA48C32AH, Flexx line\u003c\/li\u003e\n\u003cli\u003eType: cased evaporator coil\u003c\/li\u003e\n\u003cli\u003eNominal capacity: 4 tons (48,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-32\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 24-1\/2 × 28-1\/2 × 21-1\/4 in\u003c\/li\u003e\n\u003cli\u003eNet weight: 110 lb\u003c\/li\u003e\n\u003cli\u003eFlared connections: 3\/8 in for the liquid line, 3\/4 in for the suction line\u003c\/li\u003e\n\u003cli\u003eManufacturer warranty: 5 years parts, 7 years compressor (Gree Flexx brochures, U.S.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhere the FXA48C32AH fits in the series\u003c\/h3\u003e\n\u003cp\u003eFour cased Gree coils make up the series. The 4-ton sits on the second-highest step:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFXA24C32AH, 2 tons, 17-1\/2 in: for small homes and plex apartments;\u003c\/li\u003e\n\u003cli\u003eFXA36C32AH, 3 tons, 17-1\/2 in: the size for the average home;\u003c\/li\u003e\n\u003cli\u003eFXA48C32AH, 4 tons, 24-1\/2 in: this model;\u003c\/li\u003e\n\u003cli\u003eFXA60C32AH, 5 tons, 24-1\/2 in: the same width and the same cabinet, one more size of capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf you are torn between the 3-ton and the 4-ton, remember that the move to 24-1\/2 in changes which furnace is compatible, not just the capacity. Between the 4-ton and the 5-ton, the cabinet does not change: the discussion is about the home's actual load and the electrical service, not about available space.\u003c\/p\u003e\n\n\u003ch3\u003eBefore you sign\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is required on both sides: the coil and the outdoor unit are installed together.\u003c\/li\u003e\n\u003cli\u003eThe coil has no efficiency rating of its own; only the ratings of the certified pairing count.\u003c\/li\u003e\n\u003cli\u003eThe furnace must offer a 24-1\/2 in width, or receive a transition.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the system's airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA visit for a large home\u003c\/h3\u003e\n\u003cp\u003eIn a multi-storey home, the estimate visit takes a little longer, and that is normal. We go up to the attic, we go down to the basement, we look at where the main ducts run and how the upstairs rooms receive air. A bedroom that always stays warmer than the living room often points to a duct network that needs rebalancing, and it is better to know that before choosing the size.\u003c\/p\u003e\n\u003cp\u003eWe also note the possible location of the outdoor unit: open enough to breathe, a good distance from bedroom windows, and accessible for maintenance. The route of the line set between the furnace and the exterior wall is decided at that point, along with the path of the condensate drain.\u003c\/p\u003e\n\u003cp\u003eYou leave with a written quote that names the coil, the outdoor unit and the planned work, with no grey areas.\u003c\/p\u003e\n\n\u003ch3\u003eYour questions, our answers\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it heat?\u003c\/strong\u003e Yes, with a heat pump: cooling in summer, heating in winter. With a central air conditioner, the coil only cools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I reuse my outdoor unit?\u003c\/strong\u003e Generally no. R-32 and the manufacturer's specified pairing call for a new, complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs my furnace still used?\u003c\/strong\u003e It keeps its blower, and it provides backup when the outdoor air drops below the threshold we program with you.\u003c\/p\u003e\n\n\u003ch3\u003eAn electric furnace, its limits, and the alternative\u003c\/h3\u003e\n\u003cp\u003eA large home heated with electricity uses a lot, because an electric furnace produces no more heat than the energy it consumes. A heat pump, on the other hand, transfers heat from outdoors to indoors and delivers two to three times more heat than the electricity used in mild temperatures. The furnace stays in place for periods of deep cold.\u003c\/p\u003e\n\n\u003ch3\u003eThe manufacturer and the installer\u003c\/h3\u003e\n\u003cp\u003eGree Electric Appliances makes residential and commercial air conditioners and heat pumps. Its R-32 Flexx line turns a furnace into a central heat pump system, controlled by a 24 V thermostat.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, holder of RBQ licence 5645-9605-01. Our installation includes measuring the furnace, mounting the coil and its transition, brazed piping with a nitrogen test and evacuation, the condensate drain, the thermostat, then commissioning and a walkthrough.\u003c\/p\u003e\n\n\u003ch3\u003eRebates and LogisVert\u003c\/h3\u003e\n\u003cp\u003eEligibility for Hydro-Québec programs, including the LogisVert rebate, depends on the complete system, not the coil alone. We check the pairing on the official list at the time of the quote, then tell you what applies to your project.\u003c\/p\u003e\n\n\u003ch3\u003eGet your estimate\u003c\/h3\u003e\n\u003cp\u003eRequest your free on-site estimate. We measure the furnace, we check the electrical service and we give you a written quote for the complete Gree system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project, from Montreal to Laval, from Longueuil to the North Shore and the South Shore.\u003c\/p\u003e\n","brand":"Gree","offers":[{"title":"Default Title","offer_id":68402724176164,"sku":"FXA48C32AH","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_GREEFLEXX_FLEXX_FXA48C32AH_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766120","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-gree-fxa48c32ah-a-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}