{"product_id":"serpentin-devaporateur-haxxair-dc31d2j-a-2-tonnes","title":"HAXXAIR DC31D2J Evaporator A-Coil | 2 Tons","description":"\u003ch2\u003eHaxxair DC31D2J: the 2-ton evaporator coil that gives small furnaces a second wind\u003c\/h2\u003e\n\u003cp\u003ePicture a duplex in Longueuil, a compact bungalow in Laval or a townhouse on the Plateau: a furnace in the basement, ductwork serving every room, and summers still spent with window air conditioners. The \u003cstrong\u003eHaxxair DC31D2J evaporator coil\u003c\/strong\u003e is the part that changes that routine. It is a cased A-coil rated at 2 tons (24,000 BTU\/h), it runs on \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e, and it mounts directly on your existing furnace.\u003c\/p\u003e\n\u003cp\u003eConnected to the Haxxair HVHDZ-24V2D outdoor unit, it cools your home in summer. With a heat pump, it also heats in winter through the same ductwork. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhich homes this size makes sense for\u003c\/h3\u003e\n\u003cp\u003eTwo tons is the smallest size in the series. It is aimed at homes where the cooling load stays modest: a townhouse, a small bungalow, or a plex unit that has its own furnace.\u003c\/p\u003e\n\u003cp\u003eThe temptation is to go bigger \"just to be safe.\" That is a common mistake. An oversized system reaches the set temperature in a few minutes, then shuts off before it has removed the moisture from the air. The result is a house that feels cool but clammy. A well-sized system runs longer, dries the air and does not create cold drafts near the vents.\u003c\/p\u003e\n\u003cp\u003eOur visit is first about confirming that load. If the calculation points to a larger size, we will tell you plainly: the decision rests on the house, not on what is sitting on the shelf.\u003c\/p\u003e\n\n\u003ch3\u003eAn A-coil in its insulated cabinet\u003c\/h3\u003e\n\u003cp\u003eThe coil has two slanted faces that meet at the top. Air from the furnace rises through the centre and passes through both faces. The insulated cabinet wraps the whole assembly: it sits on the furnace like a ready-to-fit part, which speeds up installation and limits air leaks around the coil.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer lists two positions: upflow (standard) and downflow, with the separately sold DWNFLWP-175 kit. The metering device is a TXV R-454B (J), a valve that adjusts the refrigerant flow to the actual load at any given moment.\u003c\/p\u003e\n\n\u003ch3\u003eWhat happens in the plenum, season after season\u003c\/h3\u003e\n\u003cp\u003eIn summer, the refrigerant evaporates inside the coil tubes and absorbs heat from the air passing through. Moisture condenses on the fins, drops into the pan and leaves through the 3\/4 in NPT condensate drain.\u003c\/p\u003e\n\u003cp\u003eIn winter, with a heat pump, the cycle reverses. The refrigerant, warmed by the outdoor unit, gives up its heat to the air in your home. The furnace keeps its blower and its filters and takes over only when the outdoor temperature falls below the threshold we set with you.\u003c\/p\u003e\n\n\u003ch3\u003eTurning an electric furnace into a central heat pump\u003c\/h3\u003e\n\u003cp\u003eThis is the most common project for this model. An electric baseboard or furnace converts each kilowatt-hour into an equal amount of heat. A heat pump instead moves heat from outdoors to indoors: in mild temperatures, it delivers two to three times more heat than the electricity it uses. That efficiency drops as it gets colder, which is why keeping the furnace as backup for the coldest days makes sense.\u003c\/p\u003e\n\u003cp\u003eThe same project replaces a tired old central air conditioner. Rather than repair a unit that runs on a different refrigerant, we install a new, matched system, coil and outdoor unit together.\u003c\/p\u003e\n\n\u003ch3\u003eThe numbers that belong to the system, not the coil\u003c\/h3\u003e\n\u003cp\u003eThe DC31D2J has no efficiency rating of its own. Ratings belong to the certified system, tied together by an AHRI number. Paired with the HVHDZ-24V2D unit, the system carries \u003cstrong\u003eAHRI 218160009\u003c\/strong\u003e, with a SEER2 of 16.0 and an HSPF2 of 8.2. The outdoor unit delivers 24,000 BTU\/h in cooling and 24,000 BTU\/h in heating at 47 °F.\u003c\/p\u003e\n\u003cp\u003eWhen you compare two quotes, ask for the AHRI number on each: it is what lets you compare complete systems, and it is what subsidy programs look up.\u003c\/p\u003e\n\n\u003ch3\u003eDC31D2J or a neighbouring model in the DC series?\u003c\/h3\u003e\n\u003cp\u003eThe series has four cased coils, all using R-454B and all with a TXV R-454B (J). What changes is the size and the matching outdoor unit.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDC31D2J\u003c\/strong\u003e: 2 tons, paired with the HVHDZ-24V2D unit. The choice for small spaces.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDC37D3J\u003c\/strong\u003e: 3 tons, paired with the HVHDZ-36V2D unit, for larger homes.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDC49B3J\u003c\/strong\u003e: 4 tons, 21 in wide, paired with the HVHDZ-48V2D unit.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDC61C4J\u003c\/strong\u003e: 5 tons, 24-1\/2 in wide, paired with the HVHDZ-60V2D unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou do not pick a coil larger than the outdoor unit, or the other way around: the two are sold as a pair. The right approach is to start from the load of the house, then let the size follow.\u003c\/p\u003e\n\n\u003ch3\u003eDC31D2J specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil, DC series;\u003c\/li\u003e\n\u003cli\u003esize: 2 tons (24,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003enet weight: 41 lb;\u003c\/li\u003e\n\u003cli\u003eliquid line connection: 3\/8 in ODS; suction connection: 3\/4 in ODS;\u003c\/li\u003e\n\u003cli\u003econdensate drain: 3\/4 in NPT;\u003c\/li\u003e\n\u003cli\u003emetering device: TXV R-454B (J);\u003c\/li\u003e\n\u003cli\u003ewarranty: 10-year limited warranty on the coil, with registration (Aspen).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWith A2L-class refrigerants, a refrigerant detection system (RDS) is required. The Aspen A2LZS or A2LZR kit (with relay) is installed at the factory or on site, and the RBL list includes the A2LZR kit.\u003c\/p\u003e\n\n\u003ch3\u003eHow the installation goes at your home\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal; our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. For this coil and its outdoor unit, here is the essence of the job:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ewe measure the furnace and check the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003ewe mount the coil in the plenum, with a transition built on site if needed, and seal the connections;\u003c\/li\u003e\n\u003cli\u003ewe install the outdoor unit on a pad or bracket, braze the piping, pressure-test with nitrogen and pull a vacuum;\u003c\/li\u003e\n\u003cli\u003ewe connect the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ewe commission the system, set the airflow and explain how it works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently asked questions about this coil\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan it heat?\u003c\/strong\u003e Yes, when paired with a heat pump. With a central air conditioner, it only cools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my current air conditioner?\u003c\/strong\u003e Usually not. The coil runs on R-454B and must be paired with the outdoor unit specified by the manufacturer. We install the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy furnace is a different width. What then?\u003c\/strong\u003e We measure it and, if needed, build an insulated transition on site.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to check before you buy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B requires an outdoor unit with the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified pairing, not to the coil alone.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the airflow the system needs, and the furnace width must be suitable: we confirm both at the visit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert subsidy\u003c\/h3\u003e\n\u003cp\u003eThe paired Haxxair system appears on Hydro-Québec’s list of eligible heat pumps. Eligibility depends on the complete system and the installation date. We check the official list when we prepare your quote and put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Haxxair system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Haxxair","offers":[{"title":"Default Title","offer_id":68401006084388,"sku":"DC31D2J","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_HAXXAIR_DC_DC31D2J_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795722136","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-haxxair-dc31d2j-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}