{"product_id":"serpentin-devaporateur-haxxair-dc37d3j-a-3-tonnes","title":"HAXXAIR DC37D3J Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003eDC37D3J, the 3-ton Haxxair evaporator coil: the middle of the range and often the right compromise\u003c\/h2\u003e\n\u003cp\u003eWhen a customer in Brossard or Saint-Eustache calls us to replace an old central air conditioner, the question almost always comes up: \"What size do I need?\" For a good share of the bungalows and cottages in the region, the answer lands around 3 tons. The \u003cstrong\u003eHaxxair DC37D3J evaporator coil\u003c\/strong\u003e fills that slot: 36,000 BTU\/h nominal, insulated cabinet, A shape, \u003cstrong\u003eR-454B\u003c\/strong\u003e refrigerant.\u003c\/p\u003e\n\u003cp\u003eIt mounts on a furnace or a blower cabinet and pairs with the Haxxair HVHDZ-36V2D outdoor unit. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eOur visit, step by step\u003c\/h3\u003e\n\u003cp\u003eBefore recommending this coil, we follow the same approach every time.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWe take the width of the furnace and look at the space available in the plenum.\u003c\/li\u003e\n\u003cli\u003eWe check the blower: it is the part that has to push the required airflow through the coil.\u003c\/li\u003e\n\u003cli\u003eWe examine the electrical panel and the spot where the outdoor unit will go.\u003c\/li\u003e\n\u003cli\u003eWe calculate the load of the house room by room, rather than relying on floor area alone.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf that calculation shows that a neighbouring size suits you better, we say so. A heat pump that is too big heats or cools in short cycles and leaves moisture in the house; one that is too small works non-stop.\u003c\/p\u003e\n\n\u003ch3\u003eWhat this coil does day to day\u003c\/h3\u003e\n\u003cp\u003eAir from the house rises toward the furnace, passes through the coil and comes out cooled in summer. The water removed from the air condenses, drops into the pan and leaves through the 3\/4 in NPT drain. If a heat pump is connected, winter reverses the path of the heat: the outdoor unit picks it up outside and the coil releases it into the existing ductwork.\u003c\/p\u003e\n\u003cp\u003eThe furnace does not disappear for all that. It keeps its blower, its filters and its role as backup heat, switching on below an outdoor temperature threshold that we set with you. This is what is called an \"add-on\" heat pump.\u003c\/p\u003e\n\n\u003ch3\u003eThe certified system around the DC37D3J\u003c\/h3\u003e\n\u003cp\u003eA coil on its own has no efficiency rating. Ratings attach to the complete system. Here, the DC37D3J coil and the HVHDZ-36V2D unit make up the \u003cstrong\u003eAHRI 218160010\u003c\/strong\u003e system, with a SEER2 of 16.5 and an HSPF2 of 8.2. The outdoor unit delivers 34,000 BTU\/h in cooling and 34,000 BTU\/h in heating at 47 °F.\u003c\/p\u003e\n\u003cp\u003eHaxxair also states that its pairings are ENERGY STAR cold climate certified for Canada, with a continuously variable speed compressor and R-454B refrigerant, which has a GWP of 470.\u003c\/p\u003e\n\n\u003ch3\u003eHow it compares with its neighbours\u003c\/h3\u003e\n\u003cp\u003eIn Haxxair’s DC series, each coil is tied to a single outdoor unit. Here is how the DC37D3J compares.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSmaller: DC31D2J\u003c\/strong\u003e, 2 tons, with the HVHDZ-24V2D unit. It suits compact spaces.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eThis model: DC37D3J\u003c\/strong\u003e, 3 tons, with the HVHDZ-36V2D unit.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLarger: DC49B3J\u003c\/strong\u003e, 4 tons, 21 in wide, with the HVHDZ-48V2D unit.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLargest: DC61C4J\u003c\/strong\u003e, 5 tons, 24-1\/2 in wide, with the HVHDZ-60V2D unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll share the same TXV R-454B (J) metering device and the same refrigerant. Since the DC37D3J and the DC31D2J have the same 3\/4 in ODS suction connection, moving from one to the other does not change the piping logic; the load calculation is what decides.\u003c\/p\u003e\n\n\u003ch3\u003eWhy an electric furnace benefits from this project\u003c\/h3\u003e\n\u003cp\u003eAn electric furnace turns electricity into heat on a one-for-one basis. A heat pump moves heat instead of making it: in mild temperatures, it delivers two to three times more heat than the energy it uses. The colder it gets, the more that efficiency drops, and the furnace then takes over.\u003c\/p\u003e\n\u003cp\u003eIn summer, the same installation replaces window air conditioners. One outdoor unit, cool air in every room, a single thermostat for both seasons.\u003c\/p\u003e\n\n\u003ch3\u003eWhen to plan the work\u003c\/h3\u003e\n\u003cp\u003eMany homeowners wait for the first heat wave to call, and that is when schedules fill up. A central air conditioner replacement is better prepared in spring or fall: the furnace is easy to reach, and we take the time to measure, order the right pairing and check subsidy eligibility before the hot season.\u003c\/p\u003e\n\u003cp\u003eIf your furnace is electric and you are thinking of converting it, fall is also a good time to compare last winter’s heating bills with what a heat pump could change. Bring them to the visit: they help us set the threshold at which the furnace takes over.\u003c\/p\u003e\n\n\u003ch3\u003eDC37D3J specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil, DC series;\u003c\/li\u003e\n\u003cli\u003esize: 3 tons (36,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003enet weight: 51 lb;\u003c\/li\u003e\n\u003cli\u003eliquid line connection: 3\/8 in ODS; suction connection: 3\/4 in ODS;\u003c\/li\u003e\n\u003cli\u003epositions: upflow (standard); downflow with separately sold kit (DWNFLWP-175);\u003c\/li\u003e\n\u003cli\u003ewarranty: 10-year limited warranty on the coil, with registration (Aspen).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLeak detection is a requirement for A2L refrigerants: a refrigerant detection system (RDS) is required, and the Aspen A2LZS or A2LZR kit (with relay) is installed at the factory or on site. The RBL list includes the A2LZR kit.\u003c\/p\u003e\n\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eAt AirGreen, a \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal, refrigeration, ventilation and electrical work is covered by our RBQ licence 5645-9605-01. For this system:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emounting the coil in the plenum, with a custom transition if needed;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit on a pad or bracket, brazed piping, nitrogen test and vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and a clear explanation of how it works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThree questions we often hear\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan my old air conditioner stay?\u003c\/strong\u003e Usually not: R-454B requires the outdoor unit specified for this coil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still useful?\u003c\/strong\u003e Yes, as backup heat during the coldest weather.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this coil heat on its own?\u003c\/strong\u003e No: it heats only when paired with a heat pump. With a central air conditioner, it cools.\u003c\/p\u003e\n\n\u003ch3\u003ePoints to confirm before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe outdoor unit must use the same refrigerant and be installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified pairing.\u003c\/li\u003e\n\u003cli\u003eThe furnace width and the blower capacity are confirmed on site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert subsidy\u003c\/h3\u003e\n\u003cp\u003eThe paired Haxxair system appears on Hydro-Québec’s list of eligible heat pumps. The amount depends on the installation date and your situation. We consult the official list when we prepare the quote and put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Haxxair system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Haxxair","offers":[{"title":"Default Title","offer_id":68401007001892,"sku":"DC37D3J","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_HAXXAIR_DC_DC37D3J_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795722138","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-haxxair-dc37d3j-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}