{"product_id":"serpentin-devaporateur-lg-lkmma18a1-a-1-5-tonnes","title":"LG LKMMA18A1 Evaporator A-Coil | 1.5 Tons","description":"\u003ch2\u003eLKMMA18A1: the 14-1\/2 in. LG coil for narrow furnaces\u003c\/h2\u003e\n\u003cp\u003eIn a condo or plex mechanical room, the furnace often leaves no margin at all. That is the kind of space LG had in mind with the \u003cstrong\u003eLKMMA18A1\u003c\/strong\u003e: a cased evaporator A-coil of 1.5 tons that is only 14-1\/2 in. wide. It runs on \u003cstrong\u003eR-32 refrigerant\u003c\/strong\u003e and sits on top of a furnace or a blower cabinet. In \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, we install it with the LG outdoor unit made for it.\u003c\/p\u003e\n\n\u003ch3\u003eWhy width comes before everything else\u003c\/h3\u003e\n\u003cp\u003eBefore talking about performance, we measure. A coil that is wider than the furnace forces us to build a transition; a coil that is too narrow lets air slip around the fins. At 14-1\/2 in., the LKMMA18A1 is the narrowest of the LKMMA series we offer, and it suits the compact furnaces found in older Montreal buildings and small Longueuil bungalows.\u003c\/p\u003e\n\u003cp\u003eIts full dimensions are 14-1\/2 in. wide, 24 in. high and 21 in. deep, with a net weight of 44 lb. Two people can handle it without a hoist, which matters when the basement stairs are tight.\u003c\/p\u003e\n\n\u003ch3\u003eWhat an A-coil actually does\u003c\/h3\u003e\n\u003cp\u003ePicture two slanted fin plates leaning against each other at the top. Air from the blower rises through the centre, passes through both faces, and comes out cooler and drier. Inside the tubes, liquid refrigerant evaporates and carries heat away from the air. Moisture in the air condenses on the fins, drops into the pan and leaves through the condensate drain.\u003c\/p\u003e\n\u003cp\u003eThe drain measures 1-1\/4 in. outside diameter and 1 in. inside diameter, with an outlet possible on the left or the right. That double outlet saves a lot of detours in the piping when the water drain is on the wrong side of the mechanical room.\u003c\/p\u003e\n\n\u003ch3\u003ePairing with the KUSXA181A\u003c\/h3\u003e\n\u003cp\u003eA coil on its own has no efficiency rating. The LKMMA18A1 takes on its full meaning once it is connected to the \u003cstrong\u003eKUSXA181A\u003c\/strong\u003e outdoor unit, an LG inverter-compressor heat pump. Together they form a system carrying AHRI number 216445254, with published ratings of SEER2 15.2 and HSPF2 8.1.\u003c\/p\u003e\n\u003cp\u003eAccording to the match-up sheet, the system delivers 17,000 BTU\/h of cooling and 20,000 BTU\/h of heating at 47 °F. The refrigerant connections on the coil are 3\/8 in. on the liquid side and 3\/4 in. on the suction side.\u003c\/p\u003e\n\n\u003ch3\u003eWho should look at this model\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ethe condo owner who wants to replace a window air conditioner with a discreet central solution;\u003c\/li\u003e\n\u003cli\u003ethe plex owner whose units each have their own furnace;\u003c\/li\u003e\n\u003cli\u003ethe small, well-insulated house where the heating and cooling load stays modest;\u003c\/li\u003e\n\u003cli\u003ethe owner of an electric furnace who wants to turn it into a central heat pump, with the furnace as backup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your home is large or poorly insulated, this size will be too small. We say so plainly: the right size is calculated, not guessed.\u003c\/p\u003e\n\n\u003ch3\u003eLKMMA18A1 or LKMMA18B1: how to decide\u003c\/h3\u003e\n\u003cp\u003eBoth models have the same nominal capacity of 1.5 tons and the same refrigerant. The difference is the size: the LKMMA18B1 is 17-1\/2 in. wide, and the LKMMA18A1 only 14-1\/2 in. The first pairs with the KUSXA181A and the KUSXB181A; the second with the KUSXA181A only.\u003c\/p\u003e\n\u003cp\u003eThe rule is simple. If your furnace is narrow, the 14-1\/2 in. coil avoids a transition. If it is wider, the LKMMA18B1 fits the sheet metal better. And if you are aiming for double the capacity, look instead at the LKMMA24B1, at 2 tons, or at the 2.5-ton and 3-ton models above it.\u003c\/p\u003e\n\n\u003ch3\u003eA July without sticky air\u003c\/h3\u003e\n\u003cp\u003eReal summer comfort does not depend only on the temperature on the display: it depends on humidity. A small unit served by an oversized system cools quickly, shuts off, then starts again, without ever drying the air. A coil of this size, properly matched, runs longer and more gently. The water has time to condense on the fins, and the walls no longer keep that clammy feeling that clings to the skin during Montreal heat waves.\u003c\/p\u003e\n\u003cp\u003eIt is also quieter in a bedroom next to the mechanical room, which condo occupants appreciate where every sound carries.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil, LKMMA range;\u003c\/li\u003e\n\u003cli\u003enominal size: 1.5 tons, or 18,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-32, with a leak detection sensor noted in the LG brochure;\u003c\/li\u003e\n\u003cli\u003epositions: multi-position, meaning upflow, downflow, horizontal left or right;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in. liquid, 3\/4 in. suction;\u003c\/li\u003e\n\u003cli\u003ematched outdoor unit: KUSXA181A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHeat pump and furnace: who works when\u003c\/h3\u003e\n\u003cp\u003eIn an \"add-on\" setup, the furnace keeps its blower, its filters and its ductwork. The coil slides into the plenum, in the path of the air. In summer it cools; in winter, with a heat pump, the cycle reverses and the heat captured outdoors is delivered through the same ducts.\u003c\/p\u003e\n\u003cp\u003eThe furnace only takes over when the outdoor temperature drops below the threshold we program with you. You therefore keep backup heating for the deepest cold, which reassures many Quebec homeowners.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we check at your home before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ethe actual width of the furnace, measured on site rather than read from an old invoice;\u003c\/li\u003e\n\u003cli\u003ethe blower's ability to deliver the airflow this system needs;\u003c\/li\u003e\n\u003cli\u003ethe condition of the electrical panel and the location of the outdoor unit;\u003c\/li\u003e\n\u003cli\u003eaccess to the drain and the outlet, left or right, that suits best.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe coil uses R-32, so it is paired with an outdoor unit that uses the same refrigerant, installed at the same time. Keeping an old air conditioner is generally not possible.\u003c\/p\u003e\n\n\u003ch2\u003eOur installation in Greater Montreal\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. For this coil and its outdoor unit, the work goes like this:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, with an insulated transition built on site if the width requires it;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit on a pad or bracket, brazed piping, nitrogen leak test and vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and an explanation of how the system works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe matched LG system appears on Hydro-Québec's list of eligible heat pumps. Eligibility is based on the complete system, not on the coil alone. The amount depends on the installation date and on your situation: we check it against the official list when we prepare your quote, then put the file together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete LG system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"LG","offers":[{"title":"Default Title","offer_id":68402723651876,"sku":"LKMMA18A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_LG_LKMMA_LKMMA18A1_00_1_5_TONNES_18000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766176","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-lg-lkmma18a1-a-1-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}