{"product_id":"serpentin-devaporateur-lg-lkmma18b1-a-1-5-tonnes","title":"LG LKMMA18B1 Evaporator A-Coil | 1.5 Tons","description":"\u003ch2\u003eLG LKMMA18B1 coil: 1.5 tons, 17-1\/2 in. and a choice of two outdoor units\u003c\/h2\u003e\n\u003cp\u003eHere is a small coil with a useful feature: it accepts two outdoor partners. The \u003cstrong\u003eLKMMA18B1\u003c\/strong\u003e is a cased A-coil of 1.5 tons that runs on \u003cstrong\u003eR-32 refrigerant\u003c\/strong\u003e. It pairs with the LG KUSXA181A or the KUSXB181A outdoor unit, each with its own AHRI number. For a house in \u003cstrong\u003eLaval\u003c\/strong\u003e, a plex in \u003cstrong\u003eMontreal\u003c\/strong\u003e or a bungalow on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, that gives real freedom of choice without changing the coil.\u003c\/p\u003e\n\n\u003ch3\u003eThe three questions customers ask us most often\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it heat?\u003c\/strong\u003e Yes, as long as it is connected to a heat pump. With a plain central air conditioner, it only cools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my old air conditioner?\u003c\/strong\u003e As a rule, no. R-32 requires an outdoor unit designed for it, and the two components are installed together.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill my furnace still be useful?\u003c\/strong\u003e Yes. It provides the blower and serves as backup heating when the mercury drops below the threshold set with you.\u003c\/p\u003e\n\n\u003ch3\u003eTwo outdoor units, two AHRI numbers\u003c\/h3\u003e\n\u003cp\u003eHere are the published match-ups for this model, side by side:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ewith the \u003cstrong\u003eKUSXA181A\u003c\/strong\u003e: AHRI number 216445255, with 18,000 BTU\/h of cooling, 20,000 BTU\/h of heating at 47 °F, SEER2 15.2 and HSPF2 8.1;\u003c\/li\u003e\n\u003cli\u003ewith the \u003cstrong\u003eKUSXB181A\u003c\/strong\u003e: AHRI number 216445244, the same capacities of 18,000 and 20,000 BTU\/h, the same ratings of 15.2 and 8.1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOn paper, the two systems are equal. The choice is therefore made in the field: space available around the exterior wall, availability at the time of the order, the installer's preference for one range. We explain the practical difference during the visit and write the correct AHRI number on the quote, because it is the reference used for the rebate.\u003c\/p\u003e\n\n\u003ch3\u003eWhat \"17-1\/2 in.\" means in a mechanical room\u003c\/h3\u003e\n\u003cp\u003eThe 17-1\/2 in. width is shared by several models in the range, from 1.5 tons up to 3 tons. The coil measures 17-1\/2 in. wide, 24 in. high and 21 in. deep; it weighs 46 lb.\u003c\/p\u003e\n\u003cp\u003eIf your furnace is narrower or wider, that is not a problem: we build an insulated transition on site. But a transition adds labour, material and one more joint to seal. That is why we prefer to measure the furnace before choosing between this model and its narrower cousin.\u003c\/p\u003e\n\n\u003ch3\u003eHow it compares with its neighbours in the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eLKMMA18A1\u003c\/strong\u003e: the same capacity of 1.5 tons, but 14-1\/2 in. wide and a single partner, the KUSXA181A. The one to favour if the furnace is narrow.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLKMMA24B1\u003c\/strong\u003e: the same 17-1\/2 in. width, but 2 tons and a match with the KUSXB241A. It suits a home whose load exceeds what 1.5 tons can cover.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLKMMA30B1\u003c\/strong\u003e: still 17-1\/2 in. wide, with 2.5 tons for a larger home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn other words, when the furnace width is fixed at 17-1\/2 in., the only real variable is capacity, and the load calculation determines it.\u003c\/p\u003e\n\n\u003ch3\u003eThe load calculation comes before the catalogue\u003c\/h3\u003e\n\u003cp\u003eWe do not choose the size from floor area alone. Wall insulation, the number of windows, orientation, air tightness and the family's habits all go into the calculation. An oversized unit cycles too often, dries the air poorly and wears out its components faster. An undersized unit struggles during heat waves. For a small, well-insulated home, the 1.5-ton size is sometimes exactly what is needed; for an older home, it may simply be too modest.\u003c\/p\u003e\n\n\u003ch3\u003eThree homes, three lines of reasoning\u003c\/h3\u003e\n\u003cp\u003eA small, well-insulated townhouse in Longueuil with an average-width electric furnace: the LKMMA18B1 goes straight into the plenum, the heat pump handles most of the heating season, and the furnace stays there for the harshest days.\u003c\/p\u003e\n\u003cp\u003eA Montreal duplex whose owner replaces two window air conditioners with a central system in the upper unit: here, it is mostly the quiet and the absence of a unit in the window that make the difference. We check that the existing blower pushes enough air through all the ducts, otherwise the cooling would stay uneven.\u003c\/p\u003e\n\u003cp\u003eA North Shore home whose old central air conditioner has just given out: rather than patching it up, the owner takes the replacement as a chance to switch to a heat pump. They keep their ducts, remove the old coil and the old outdoor unit, then have the new set installed all at once.\u003c\/p\u003e\n\n\u003ch3\u003eWhy the certified match-up matters\u003c\/h3\u003e\n\u003cp\u003eWhen two quotes compete, compare the AHRI numbers before the prices. That number links a specific coil to a specific outdoor unit; it confirms that the combination was rated as a whole. A coil chosen at random, even a good one, carries no rating: it is the whole system that counts, and it is also the whole system that is submitted to Hydro-Québec's eligibility list.\u003c\/p\u003e\n\u003cp\u003eLG publishes several match-ups of LKMMA coils certified ENERGY STAR for Canada and the United States, all cold-climate, which is consistent with our Quebec winters.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: LKMMA18B1, cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003enominal size: 1.5 tons (18,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003e3\/8 in. liquid connection, 3\/4 in. suction connection;\u003c\/li\u003e\n\u003cli\u003econdensate drain of 1-1\/4 in. O.D. and 1 in. I.D., left and right;\u003c\/li\u003e\n\u003cli\u003emultiple positions: upflow, downflow, horizontal left or right;\u003c\/li\u003e\n\u003cli\u003eR-32 detection sensor mentioned in the LG brochure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOn the furnace: what stays, what changes\u003c\/h3\u003e\n\u003cp\u003eThe existing blower, filters and ductwork are kept. The coil is added in the plenum, in the path of the air. In winter, with the heat pump, outdoor heat passes through the refrigerant and then into the air of the house; the furnace takes over when needed. Nothing to replace on the distribution side, which reduces the scope of the work.\u003c\/p\u003e\n\u003cp\u003eThe coil has no efficiency rating of its own: the ones you see on a quote belong to the matched system.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation at your home, from the first call to commissioning\u003c\/h2\u003e\n\u003cp\u003eOur heating and cooling team, based in Montreal and active in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and throughout Greater Montreal, always follows the same sequence:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea visit, measuring the furnace and examining the electrical panel;\u003c\/li\u003e\n\u003cli\u003echecking the blower, which must deliver the system's airflow;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, sealing the duct joints;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a bracket, brazing the pipes, nitrogen test, vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the drain and the thermostat, then final adjustment and explanation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTo check before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil and the outdoor unit must share the same refrigerant, R-32.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified match-up, not to a mix of parts from different sources.\u003c\/li\u003e\n\u003cli\u003eThe furnace width must be confirmed on site before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe matched LG system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation. We check it against the official list when we prepare your quote and put the file together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete LG system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"LG","offers":[{"title":"Default Title","offer_id":68402725290276,"sku":"LKMMA18B1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_LG_LKMMA_LKMMA18B1_00_1_5_TONNES_18000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766176","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-lg-lkmma18b1-a-1-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}