{"product_id":"serpentin-devaporateur-lg-lkmma36c1-a-3-tonnes","title":"LG LKMMA36C1 Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003eLKMMA36C1: the 3-ton LG coil in a 21 in. cabinet, matched with the KUSXA361A or the KUSXB361A\u003c\/h2\u003e\n\u003cp\u003eHere are the essentials in a few lines, before getting into the details. The \u003cstrong\u003eLKMMA36C1\u003c\/strong\u003e is a cased evaporator A-coil of 3 tons (36,000 BTU\/h) that runs on \u003cstrong\u003eR-32 refrigerant\u003c\/strong\u003e. Its width is 21 in. It pairs with the KUSXA361A or the KUSXB361A. With the first, the published ratings reach SEER2 16.0 and HSPF2 8.9. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eIdentity card\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003edimensions W × H × D: 21 × 26 × 21 in.;\u003c\/li\u003e\n\u003cli\u003enet weight: 55 lb;\u003c\/li\u003e\n\u003cli\u003e3\/8 in. liquid connection, 3\/4 in. suction connection;\u003c\/li\u003e\n\u003cli\u003econdensate drain of 1-1\/4 in. O.D. and 1 in. I.D., left and right;\u003c\/li\u003e\n\u003cli\u003epositions: upflow, downflow, horizontal left or horizontal right;\u003c\/li\u003e\n\u003cli\u003eR-32 detection sensor mentioned in the LG brochure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTwo certified systems around the same coil\u003c\/h3\u003e\n\u003cp\u003eLike its cousin the LKMMA36B1, this model accepts two 3-ton outdoor units. The published match-ups are as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ewith the \u003cstrong\u003eKUSXA361A\u003c\/strong\u003e: AHRI number 216445259, with 34,400 BTU\/h of cooling, 37,000 BTU\/h of heating at 47 °F, SEER2 16.0, HSPF2 8.9;\u003c\/li\u003e\n\u003cli\u003ewith the \u003cstrong\u003eKUSXB361A\u003c\/strong\u003e: AHRI number 216445248, the same capacities of 34,400 and 37,000 BTU\/h, SEER2 15.5, HSPF2 8.5.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn other words, the choice of outdoor unit noticeably changes the ratings, even though the capacities stay the same. We often repeat it to customers: the coil alone has no rating, and the AHRI number describes a pair.\u003c\/p\u003e\n\n\u003ch3\u003eWhy a wider cabinet can make sense\u003c\/h3\u003e\n\u003cp\u003eA 21 in. coil gives the air a wider path than a 17-1\/2 in. model. In mechanical rooms with a wide furnace, it matches the sheet metal without a transition, which keeps the installation cleaner and reduces the risk of air leaks around the plenum. The ratings for this match-up are published by LG, and we hand you the complete sheet with the quote.\u003c\/p\u003e\n\u003cp\u003eIt would be tempting to believe that the cabinet width alone explains the efficiency rating; LG does not say so, and neither do we. Compare AHRI numbers, never impressions: it is the only honest way to put two quotes side by side.\u003c\/p\u003e\n\n\u003ch3\u003eIf the furnace is narrow, this is not the right choice\u003c\/h3\u003e\n\u003cp\u003eA 21 in. coil on a 17-1\/2 in. furnace requires building a more flared transition. In that case, the LKMMA36B1, of the same capacity, avoids the extra work. And if your furnace is even wider, up to 24-1\/2 in., look at the D line, which starts at 4 tons with the LKMMA48D1.\u003c\/p\u003e\n\u003cp\u003eAt the same 21 in. width, you will also find the LKMMA42C1 (3.5 tons), the LKMMA48C1 (4 tons) and the LKMMA60C1 (5 tons). All share this width, which makes an eventual upgrade easier if the house expands: you do not change furnace size, only capacity.\u003c\/p\u003e\n\n\u003ch3\u003eWhere this model installs best\u003c\/h3\u003e\n\u003cp\u003eMechanical rooms in homes built with a good-sized furnace, for example in the residential neighbourhoods of Laval or on the South Shore, often offer the clearance needed. Access is from the top of the furnace: the insulated cabinet sits on the unit, the refrigerant connections exit on one side, and the condensate drain takes whichever outlet suits. Because the coil accepts several positions, it can also be placed horizontally in an accessible attic or crawl space.\u003c\/p\u003e\n\u003cp\u003eWe also assess the piping route to the outdoor unit: the shorter and more direct it is, the cleaner the installation. When the exterior wall is far from the mechanical room, we say so at the visit and propose a realistic route.\u003c\/p\u003e\n\n\u003ch3\u003eWhat you keep, what you add\u003c\/h3\u003e\n\u003cp\u003eYou keep the blower, the filters, the ducts and the furnace itself. You add the coil, the outdoor unit, the refrigerant piping and a compatible thermostat. For the owner, that means a job in a few well-ordered steps rather than a renovation of the distribution system.\u003c\/p\u003e\n\n\u003ch3\u003eWhen the house changes\u003c\/h3\u003e\n\u003cp\u003eFamilies change: a basement that becomes a playroom, an addition at the back, a finished attic. Each addition changes the load. If you are planning an expansion, tell us before the quote: we take it into account in the calculation and tell you whether a different capacity would be wiser. That avoids installing a system today that will be poorly matched in two years.\u003c\/p\u003e\n\n\u003ch3\u003eQuestions and answers\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this coil heat the house?\u003c\/strong\u003e Yes, when it is paired with a heat pump: it cools in summer and heats in winter. With a central air conditioner, it only provides cooling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan my old air conditioner stay?\u003c\/strong\u003e Generally not. The coil runs on R-32 and must be connected to the outdoor unit specified by the manufacturer. We install the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs my furnace still useful?\u003c\/strong\u003e Yes. It keeps its blower and serves as backup when the outdoor temperature drops below the threshold that we program with you.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnd if the width does not match?\u003c\/strong\u003e We measure the furnace and, if needed, build an insulated transition on site.\u003c\/p\u003e\n\n\u003ch3\u003eThe path of the air and the refrigerant\u003c\/h3\u003e\n\u003cp\u003eReturn air is drawn in by the blower, rises into the plenum and passes through both faces of the A. The refrigerant, arriving as a liquid, evaporates in the tubes and cools the air. Moisture condenses in the pan and drains away. In winter, the heat pump reverses the cycle. In both cases, the furnace and its ducts stay in place.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation by AirGreen\u003c\/h2\u003e\n\u003cp\u003eA family-owned heating and cooling company based in Montreal, AirGreen does the job from start to finish:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, with a transition built on site if necessary, and sealing the connections;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed piping, nitrogen leak test, vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment, explanation of the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTo check before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe same refrigerant on both sides: R-32.\u003c\/li\u003e\n\u003cli\u003ePublished ratings valid for the certified match-up only.\u003c\/li\u003e\n\u003cli\u003eA blower able to deliver the airflow needed for 3 tons.\u003c\/li\u003e\n\u003cli\u003eThe 21 in. width confirmed on site before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe matched LG system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation. We check it against the official list when we prepare your quote, then put the file together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete LG system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"LG","offers":[{"title":"Default Title","offer_id":68402727256356,"sku":"LKMMA36C1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_LG_LKMMA_LKMMA36C1_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766176","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-lg-lkmma36c1-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}