{"product_id":"serpentin-devaporateur-lg-lkmma48d1-a-4-tonnes","title":"LG LKMMA48D1 Evaporator A-Coil | 4 Tons","description":"\u003ch2\u003eLKMMA48D1: the large 24-1\/2 in. LG cabinet for a 4-ton system\u003c\/h2\u003e\n\u003cp\u003eSome mechanical rooms look like machine rooms: a large furnace, space above it, ducts of generous size. For these installations, LG offers the \u003cstrong\u003eLKMMA48D1\u003c\/strong\u003e, a cased evaporator A-coil of 4 tons, 24-1\/2 in. wide and 34 in. high. It runs on \u003cstrong\u003eR-32 refrigerant\u003c\/strong\u003e and pairs with the KUSXA482A or the KUSXB481A. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, in \u003cstrong\u003eLaval\u003c\/strong\u003e, in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eA size to measure before dreaming about it\u003c\/h3\u003e\n\u003cp\u003eAt 24-1\/2 in. wide, 34 in. high and 21 in. deep, this cabinet is one of the most imposing in the series; it weighs 73 lb net. It is not a model you order blind. Here is what we measure at your home:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe width of the furnace, which must be close to 24-1\/2 in., otherwise a transition becomes necessary;\u003c\/li\u003e\n\u003cli\u003ethe clear height above the unit, since a 34 in. cabinet requires real clearance;\u003c\/li\u003e\n\u003cli\u003ethe route to the mechanical room, with the 73 lb weight to manoeuvre on the stairs;\u003c\/li\u003e\n\u003cli\u003ethe path of the piping to the outdoor unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn many homes, these measurements are enough to decide between this model and the LKMMA48C1, which has the same capacity but is narrower.\u003c\/p\u003e\n\n\u003ch3\u003eThe published ratings for this match-up\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eKUSXA482A\u003c\/strong\u003e, AHRI number 216445262: 45,500 BTU\/h of cooling, 50,000 BTU\/h of heating at 47 °F, SEER2 16.1, HSPF2 9.1;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eKUSXB481A\u003c\/strong\u003e, AHRI number 216445251: 45,500 BTU\/h of cooling, 48,000 BTU\/h of heating at 47 °F, SEER2 15.5, HSPF2 8.5.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWith the KUSXA482A, this coil reaches SEER2 16.1 and HSPF2 9.1, the highest published values among the LKMMA coil match-ups that LG has certified. That is an interesting indication, but keep in mind that only the complete system carries the rating: the coil has none on its own.\u003c\/p\u003e\n\n\u003ch3\u003eThe D versus the C, at equal capacity\u003c\/h3\u003e\n\u003cp\u003eThe LKMMA48C1 also offers 4 tons, with a 21 in. width and three possible match-ups. The LKMMA48D1 is wider at 24-1\/2 in., taller, heavier, and limited to two match-ups. What matters, in the end, is the furnace: if yours is wide, the D sits on it naturally; if it is more modest, the C avoids a bulky transition.\u003c\/p\u003e\n\u003cp\u003eThe LKMMA60D1 has the same 24-1\/2 in. width and goes up to 5 tons with the KUSXB601A. The two D models therefore resemble each other in size and differ in capacity.\u003c\/p\u003e\n\n\u003ch3\u003eWhat a large cabinet brings, without exaggeration\u003c\/h3\u003e\n\u003cp\u003eA larger cabinet offers more frontal surface to the air passing through the fins. There is nothing magic about it: the quality of air distribution depends mostly on the ducts and the blower. But in a home where the network is generous, a coil that matches the network avoids creating a bottleneck at the centre of the system.\u003c\/p\u003e\n\n\u003ch3\u003eWhere the heat pump's heat makes the difference\u003c\/h3\u003e\n\u003cp\u003eIn a large home heated with electricity, the heat pump absorbs most of the heating season when the weather is moderate. The furnace stays in reserve and takes over below the threshold that we set with you. In summer, the same coil cools and dries the air on both floors through the ducts already in place, with no window units.\u003c\/p\u003e\n\n\u003ch3\u003eThe transition: when the furnace is not the right width\u003c\/h3\u003e\n\u003cp\u003eMany owners learn at this point that a coil does not need to match the furnace exactly. An insulated sheet-metal transition, built on site, connects the two sizes. Done well, it is airtight, quiet and invisible once the mechanical room is closed up. Done badly, it leaks and whistles. That is why we design it after measuring, seal every joint, and insulate the whole assembly to avoid condensation on the cold sheet metal.\u003c\/p\u003e\n\u003cp\u003eIf your furnace is clearly narrower than 24-1\/2 in., it is often simpler, and cleaner, to choose a coil of a closer width rather than multiply the adaptations.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation day\u003c\/h3\u003e\n\u003cp\u003eA 73 lb cabinet is not placed at arm's length. Two technicians lift the coil, centre it on the furnace, check that it is plumb and that the pan slopes correctly, then connect the condensate drain to the most practical outlet, left or right. Next come the refrigerant connections, brazed with nitrogen flowing through the pipes to keep the inside clean, then the leak test and the vacuum. Each step is checked before moving to the next: a small defect caught early costs a few minutes; the same defect after start-up can cost a day.\u003c\/p\u003e\n\u003cp\u003eWe finish by explaining the thermostat, the furnace changeover threshold and routine maintenance, such as replacing the filters.\u003c\/p\u003e\n\n\u003ch3\u003eFor whom does this model make the most sense?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ethe owner of a large home whose furnace offers a cabinet of generous width;\u003c\/li\u003e\n\u003cli\u003ethe one who wants a 4-ton with the option of relying on the KUSXA482A and its published ratings;\u003c\/li\u003e\n\u003cli\u003ethe owner who already plans regular maintenance and an accessible mechanical room.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your furnace is narrower, or if your home is smaller, the 21 in. or 17-1\/2 in. wide models will probably be better suited.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: LKMMA48D1, LKMMA range;\u003c\/li\u003e\n\u003cli\u003enominal size: 4 tons (48,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003e3\/8 in. liquid connection, 3\/4 in. suction connection;\u003c\/li\u003e\n\u003cli\u003econdensate drain of 1-1\/4 in. O.D. and 1 in. I.D., left and right;\u003c\/li\u003e\n\u003cli\u003einstallation positions: upflow, downflow, horizontal left or right;\u003c\/li\u003e\n\u003cli\u003eR-32 detection sensor according to the LG brochure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation at your home by AirGreen\u003c\/h2\u003e\n\u003cp\u003eA family-owned heating and cooling company based in Montreal for more than fifteen years, AirGreen takes care of the whole job:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, with a transition built on site if needed, and sealing the duct connections;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed piping, nitrogen leak test, vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment, explanation of how the system works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTo check before choosing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil uses R-32: it pairs with an outdoor unit using the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe ratings apply to the certified match-up, not to the coil alone.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the system's airflow and the space must accommodate 24-1\/2 in. by 34 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe matched LG system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation: we check it against the official list when we prepare your quote and put the file together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete LG system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"LG","offers":[{"title":"Default Title","offer_id":68402728108324,"sku":"LKMMA48D1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_LG_LKMMA_LKMMA48D1_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766261","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-lg-lkmma48d1-a-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}