{"product_id":"serpentin-devaporateur-midea-mcpm4860cn10th-a-5-tonnes","title":"MIDEA MCPM4860CN10TH Evaporator A-Coil | 5 Tons","description":"\u003ch2\u003eMCPM4860CN10TH: a 5-ton Midea evaporator coil, 30 in high, for larger homes\u003c\/h2\u003e\n\u003cp\u003eWhen a home spreads over several levels, the basement has been finished and an addition has been built over the years, capacity becomes more important. The \u003cstrong\u003eMidea MCPM4860CN10TH evaporator coil\u003c\/strong\u003e meets that need with a nominal size of 5 tons, or 60,000 BTU\/h. Its cabinet is 21 in wide by 30 in high, it belongs to the ATOM X line and it uses R-454B refrigerant.\u003c\/p\u003e\n\u003cp\u003eWe install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, for homeowners who want air conditioning, and heating with a heat pump, without redoing their ductwork.\u003c\/p\u003e\n\n\u003ch3\u003eWhat 5 tons asks of the home\u003c\/h3\u003e\n\u003cp\u003eA large capacity is not just a catalogue choice. Two things get checked first:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003ethe electrical service\u003c\/strong\u003e, which must accommodate the outdoor unit’s circuit;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ethe air distribution\u003c\/strong\u003e, meaning ducts and a blower able to reach the airflow the system calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe examine both at the visit. And if the picture of the home suggests that two more modest systems would serve it better than one big one, we tell you frankly, even if it changes the quote.\u003c\/p\u003e\n\n\u003ch3\u003eHow the coil fits with the furnace\u003c\/h3\u003e\n\u003cp\u003eThe coil is A-shaped and sits in the plenum, in the path of the air heated or cooled by your blower. Its insulated cabinet is delivered ready to install. The full dimensions are 21 in wide, 30 in high and 21 in deep, in a multiposition configuration.\u003c\/p\u003e\n\u003cp\u003eThe 30 in height is something to measure: a low plenum or limited space above the furnace can complicate things. We check it on site before any order. As for the 21 in width, it must match that of the furnace; otherwise, we build an insulated transition.\u003c\/p\u003e\n\n\u003ch3\u003eWho is this model relevant for?\u003c\/h3\u003e\n\u003cp\u003eThe typical profile is a large property: a finished basement where people really live, an added storey, a cathedral-ceiling living room or a sunroom turned into living space. These spaces add air volume to treat, often without the original furnace having been reviewed. It is the largest common residential size, and it deserves a serious look before it is chosen.\u003c\/p\u003e\n\u003cp\u003eIn Laval or on the North Shore, where large homes are common, we often see this scenario. On the South Shore and in Montreal, it shows up more in extended homes or plexes where several levels are occupied.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we look at during the visit\u003c\/h3\u003e\n\u003cp\u003eWe start with the furnace: its width, the condition of the plenum, the blower’s capacity. We then move on to the electrical panel, because the outdoor unit needs its own circuit. Finally, we go through the main ducts to judge whether air can circulate at the required airflow. A written quote follows, with the complete Midea system and its AHRI number.\u003c\/p\u003e\n\n\u003ch3\u003eTwo outdoor units to choose from\u003c\/h3\u003e\n\u003cp\u003eThe MCPM4860CN10TH pairs with two certified Midea outdoor units:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eMDV-V48WMN10T\u003c\/strong\u003e, AHRI 216054430, cooling 48,000 BTU\/h, heating 48,000 BTU\/h at 47 °F, SEER2 16.0, HSPF2 8.9;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMDV-V60WMN10T\u003c\/strong\u003e, AHRI 216054431, cooling 52,000 BTU\/h, heating 54,000 BTU\/h at 47 °F, SEER2 16.0, HSPF2 8.9.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe efficiency ratings go with the set, not with the coil alone. When you compare quotes, the AHRI number tells you whether you are really talking about the same system.\u003c\/p\u003e\n\n\u003ch3\u003eBetween the 5-ton CN and DN\u003c\/h3\u003e\n\u003cp\u003eThe series has two 5-ton coils. This one is the narrower of the two:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe \u003cstrong\u003eMCPM4860CN10TH\u003c\/strong\u003e is 21 in wide and comes with the MDV-V48WMN10T outdoor unit;\u003c\/li\u003e\n\u003cli\u003ethe \u003cstrong\u003eMCPM4860DN10TH\u003c\/strong\u003e is 24-1\/2 in wide and comes with the MDV-V60WMN10T.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe two 3-ton coils in the series, the MCPM3036BN10TH and the MCPM3036CN10TH, are smaller in capacity. The BN fits in 17-1\/2 in, the CN in 21 in. All have a TXV, a cabinet and the same refrigerant, so the decision comes down to capacity and the width of your furnace.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the coil does, season after season\u003c\/h3\u003e\n\u003cp\u003eIn summer, the refrigerant evaporates in the tubes, absorbs heat from the air passing through and dries the home slightly; the condensation runs to the drain. In winter, with a heat pump, the direction of the cycle reverses and the air receives the heat captured outdoors. The furnace serves as backup when the temperature drops below a threshold that we set with you.\u003c\/p\u003e\n\u003cp\u003eWith a central air conditioner, the function remains cooling only. The heat pump is what adds heating.\u003c\/p\u003e\n\n\u003ch3\u003eWhat changes when you replace the old equipment\u003c\/h3\u003e\n\u003cp\u003eReplacing an old central air conditioner with a new system, or switching from an electric furnace to a heat pump, redistributes your heating costs. Part of the season shifts to the heat pump, which moves heat instead of making it. The furnace stays there for the cold peaks. Since the system is controlled by a single thermostat, you keep simple operation.\u003c\/p\u003e\n\n\u003ch3\u003eA matter of patience when choosing\u003c\/h3\u003e\n\u003cp\u003eEquipment of this size isn’t chosen in a rush. Take the time to compare quotes, to ask for the AHRI number of each system and to ask your questions about airflow. We would rather answer ten questions before signing than explain a surprise after installation.\u003c\/p\u003e\n\n\u003ch3\u003eSpec sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: MCPM4860CN10TH, ATOM X line;\u003c\/li\u003e\n\u003cli\u003etype: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003enominal size: 5 tons (60,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B, with TXV;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid, 3\/4 in suction;\u003c\/li\u003e\n\u003cli\u003eleak detection: R-454B compatible refrigerant detector;\u003c\/li\u003e\n\u003cli\u003emanufacturer’s warranty: 10 years compressor, 10 years parts, 10 years labour.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOur work, step by step\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company in Montreal. Our refrigeration, ventilation and electrical work falls under RBQ licence 5645-9605-01. On this type of project, we proceed as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003evisit, furnace measurement, blower and panel check;\u003c\/li\u003e\n\u003cli\u003einstallation of the coil in the plenum and sealing of the connections;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed piping, nitrogen test, vacuum;\u003c\/li\u003e\n\u003cli\u003econnection of the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and explanations at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my current air conditioner?\u003c\/strong\u003e Generally not. This coil uses R-454B and requires the manufacturer’s outdoor unit. We install the complete set.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy furnace isn’t the same width.\u003c\/strong\u003e We measure it and, if needed, build an insulated transition on site.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still useful?\u003c\/strong\u003e Yes, with its blower, its filters and its role as backup heat.\u003c\/p\u003e\n\n\u003ch3\u003eTo confirm before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B refrigerant requires an outdoor unit of the same type, installed at the same time;\u003c\/li\u003e\n\u003cli\u003ethe published ratings apply to the certified pairing;\u003c\/li\u003e\n\u003cli\u003ethe furnace must have the right width and a suitable blower, which we confirm at the visit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe matched Midea system appears on Hydro-Québec’s list of eligible heat pumps. The amount varies with the installation date and your situation. We check the official list at the quote and put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eTake the next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Midea system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Midea","offers":[{"title":"Default Title","offer_id":68401596498212,"sku":"MCPM4860CN10TH","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_MIDEA_ATOM_X_MCPM4860CN10TH_00_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795724118","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-midea-mcpm4860cn10th-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}