{"product_id":"serpentin-devaporateur-samsung-hc48mbc021h1-a-4-tonnes","title":"SAMSUNG HC48MBC021H1 Evaporator A-Coil | 4 Tons","description":"\u003ch2\u003eHC48MBC021H1: the 4-ton Samsung coil for two-storey homes and large bungalows\u003c\/h2\u003e\n\u003cp\u003eA two-storey house, a large bungalow with a finished basement, an enlarged cottage: in these buildings, the air has to travel long distances and pass through many rooms. The \u003cstrong\u003eSamsung HC48MBC021H1 evaporator coil\u003c\/strong\u003e is designed for this kind of home. It offers 4 tons (48,000 BTU\/h) in a 21 in cabinet, with R-454B refrigerant.\u003c\/p\u003e\n\u003cp\u003eThis is a cased A-coil from the Hylex line. It goes on the furnace and is paired with the Samsung \u003cstrong\u003eAC036FCUPCG\/AA\u003c\/strong\u003e outdoor unit. AirGreen installs it in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eAirflow, the first criterion at this size\u003c\/h3\u003e\n\u003cp\u003eThe more capacity goes up, the more air is needed for it to be really useful. At 4 tons, the coil and the blower are asked to do more than in a small house. If the blower does not deliver the required airflow, two things can happen: the coil freezes up, or the house lacks comfort despite a sturdy unit.\u003c\/p\u003e\n\u003cp\u003eThat is why we check the blower before even talking about price. We also look at the condition of the main ducts: a choked duct system does not let through the air the coil needs.\u003c\/p\u003e\n\n\u003ch3\u003eThe 21 in width and the furnace\u003c\/h3\u003e\n\u003cp\u003eAt this size, the coil’s width often increases, and it has to line up with that of the furnace. A narrower furnace can receive the coil with a transition; we build it and insulate it on site. The cabinet measures 21 × 27-1\/2 × 21 in and weighs 53 lb: it takes two people to handle, but it goes in without special equipment.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer lists multi-position installation: vertical, horizontal left or right. The metering device is a TXV.\u003c\/p\u003e\n\n\u003ch3\u003eThe certified system and its published values\u003c\/h3\u003e\n\u003cp\u003eThe pairing with the AC036FCUPCG\/AA unit carries AHRI number \u003cstrong\u003e218158141\u003c\/strong\u003e. Here is what is published:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ecooling: 34,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003eheating: 35,000 BTU\/h at 47 °F;\u003c\/li\u003e\n\u003cli\u003esystem ratings, SEER2 \/ HSPF2: 16.0 \/ 8.5.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese values come from the complete system. The coil has no efficiency rating of its own, and it is the AHRI number that lets you compare two quotes honestly.\u003c\/p\u003e\n\n\u003ch3\u003eWhere it stands among the other Samsung coils in the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSame width, different capacity:\u003c\/strong\u003e the HC36MCC021H1 (3 tons) and the HC60MBC021H1 (5 tons) are also 21 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLess capacity:\u003c\/strong\u003e the 2-ton and 3-ton models (HC24MCB021H1, HC36MBB021H1) are 17-1\/2 in wide.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMore capacity and more width:\u003c\/strong\u003e the 5-ton HC60MAD021H1 and HC60MCD021H1 measure 24-1\/2 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOne common point:\u003c\/strong\u003e R-454B and a TXV metering device throughout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your home’s load calculation falls between two sizes, we would rather tell you so frankly than sell you the biggest unit.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased coil, model HC48MBC021H1;\u003c\/li\u003e\n\u003cli\u003enominal size: 4 tons (48,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid and 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003econdensate drain: two 3\/4 in female pipe thread (FPT) connections, at the front left and front right;\u003c\/li\u003e\n\u003cli\u003ebuilt-in R-454B leak detector, factory installed;\u003c\/li\u003e\n\u003cli\u003ewarranty: 10 years compressor, 10 years parts; registration required; conditions apply (Samsung quote).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HA00A00203H1 mitigation controller is mandatory. It is sold separately and we include it in the quote.\u003c\/p\u003e\n\n\u003ch3\u003eWhat Samsung publishes for the 4-ton and 5-ton outdoor units\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHylex Premium: cooling from -20 to 50 °C, heating down to -25 °C;\u003c\/li\u003e\n\u003cli\u003e100% of nominal heating capacity at -10 °C for the 4-ton and 5-ton Premium models;\u003c\/li\u003e\n\u003cli\u003eHylex Standard: cooling from -20 to 50 °C, heating down to -25 °C; not ENERGY STAR certified;\u003c\/li\u003e\n\u003cli\u003einverter-driven twin rotary BLDC compressor, R-454B refrigerant;\u003c\/li\u003e\n\u003cli\u003epiping: maximum length of 164 ft (50 m), maximum elevation difference of 98 ft (30 m).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA winter with a heat pump on a furnace\u003c\/h3\u003e\n\u003cp\u003eIn a large house, the heating bill weighs heavily. An electric furnace turns each kilowatt-hour into an equal amount of heat; a heat pump moves heat from outdoors and delivers two to three times more than the electricity it consumes when the weather is mild. When the cold becomes intense, the furnace takes over, according to the threshold we set with you. The coil is the part that lets this heat pass into the duct air.\u003c\/p\u003e\n\n\u003ch3\u003eThe homes where this size makes sense\u003c\/h3\u003e\n\u003cp\u003eThink of the two-storey cottage whose furnace blows upward through long ducts, the row townhouse with a finished basement, or the large bungalow built around a single central hallway. In each of these cases, a small capacity struggles to keep up; a 4-ton coil, well supplied with air, keeps a more even temperature from room to room.\u003c\/p\u003e\n\u003cp\u003eConversely, if the house is well insulated and of average size, a smaller size may be enough. We do the load calculation before recommending anything, because an oversized unit keeps shutting off and restarting and lets humidity settle in.\u003c\/p\u003e\n\u003ch3\u003eWhat we do with the piping\u003c\/h3\u003e\n\u003cp\u003eThe 3\/8 in liquid connection and the 7\/8 in suction connection join the coil to the outdoor unit. The piping is brazed, insulated, then pressure-tested with nitrogen before the vacuum is pulled. This step may seem meticulous, but it is what keeps an R-454B circuit tight for years to come.\u003c\/p\u003e\n\u003ch3\u003eOur installation method\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-run heating and cooling company in Montreal for more than fifteen years, holder of RBQ licence 5645-9605-01. On this system, we:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasure the furnace, test the blower and inspect the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstall the cabinet on the plenum and seal the duct connections;\u003c\/li\u003e\n\u003cli\u003eset the outdoor unit, braze the piping, test for leaks with nitrogen and pull a vacuum;\u003c\/li\u003e\n\u003cli\u003econnect the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommission everything and adjust the airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe paired Samsung system appears on Hydro-Québec’s list of eligible heat pumps. The amount depends on the installation date and your situation: we check it against the official list at the time of the quote and prepare the application with you.\u003c\/p\u003e\n\n\u003ch3\u003eAfter installation\u003c\/h3\u003e\n\u003cp\u003eWe show you the filter, the drain and the thermostat, then leave a detailed quote that serves as a reference. If you have a doubt during the season, call us: it is better to check early than to wait for a breakdown.\u003c\/p\u003e\n\u003ch3\u003eQuestions we are often asked\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this coil provide heating?\u003c\/strong\u003e Yes, with a heat pump. With a central air conditioner, it only provides cooling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my current air conditioner?\u003c\/strong\u003e Generally no: R-454B requires the outdoor unit specified by the manufacturer. We install the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still useful?\u003c\/strong\u003e Yes, it keeps its blower and serves as backup in the coldest weather.\u003c\/p\u003e\n\n\u003ch3\u003eTo confirm before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil and the outdoor unit must share the same refrigerant.\u003c\/li\u003e\n\u003cli\u003eThe furnace width must be suitable, or a transition must be planned.\u003c\/li\u003e\n\u003cli\u003eThe blower must reach the system’s airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA 4-ton Samsung coil, installed by AirGreen\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Samsung system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Samsung","offers":[{"title":"Default Title","offer_id":68401600135460,"sku":"HC48MBC021H1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_SAMSUNG_HYLEX_HC48MBC021H1_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795724042","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-samsung-hc48mbc021h1-a-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}