{"product_id":"serpentin-devaporateur-samsung-hc60mbc021h1-a-5-tonnes","title":"SAMSUNG HC60MBC021H1 Evaporator A-Coil | 5 Tons","description":"\u003ch2\u003eHC60MBC021H1: a 21 in cabinet, 5 tons and two possible outdoor units\u003c\/h2\u003e\n\u003cp\u003eMost coils in our Samsung catalogue pair with a single outdoor unit. The \u003cstrong\u003eHC60MBC021H1\u003c\/strong\u003e is an exception: two pairings are published, one with the \u003cstrong\u003eAC048FCUPCG\/AA\u003c\/strong\u003e, the other with the \u003cstrong\u003eAC060FCUPCG\/AA\u003c\/strong\u003e. For a homeowner who is unsure about capacity, that is useful flexibility. It does come with a choice to make, and it is better to understand it before signing.\u003c\/p\u003e\n\u003cp\u003eThis cased A-coil, from the Samsung Hylex line, is a 5-ton (60,000 BTU\/h) unit using R-454B refrigerant, 21 in wide. It is installed in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eFirst pairing: with the AC048FCUPCG\/AA\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAHRI number: 218159516;\u003c\/li\u003e\n\u003cli\u003ecooling: 45,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003eheating: 48,000 BTU\/h at 47 °F;\u003c\/li\u003e\n\u003cli\u003esystem ratings, SEER2 \/ HSPF2: 15.3 \/ 8.2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSecond pairing: with the AC060FCUPCG\/AA\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ecooling: 53,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003eheating: 55,000 BTU\/h at 47 °F;\u003c\/li\u003e\n\u003cli\u003esystem ratings, SEER2 14.5, HSPF2 8.2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth combinations have their supporters. The first delivers less nominal capacity but shows a higher SEER2 rating; the second offers more nominal capacity with a lower SEER2 rating. Which suits your home? It is the load calculation, not the spec sheet, that decides.\u003c\/p\u003e\n\n\u003ch3\u003eA framework for choosing between the two units\u003c\/h3\u003e\n\u003cp\u003eStart by asking about the home’s real load. If it is close to the limit of the smaller unit, the larger one will avoid pushing it to the maximum on the hottest or coldest days. If the load is lower, the smaller unit will avoid short cycling and keep better control of humidity.\u003c\/p\u003e\n\u003cp\u003eThink about electricity too: the larger unit needs a circuit sized for it, which we confirm at the electrical panel. Finally, a house with far more rooms than the coil can reasonably serve may do better with two smaller systems. We say so frankly when that is the case.\u003c\/p\u003e\n\n\u003ch3\u003ePlacing the HC60MBC021H1 among its 5-ton siblings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe HC60MAD021H1 and the HC60MCD021H1 are 24-1\/2 in wide. They suit wider furnaces.\u003c\/li\u003e\n\u003cli\u003eThe HC60MBC021H1 stays at 21 in, like the HC36MCC021H1 (3 tons) and HC48MBC021H1 (4 tons).\u003c\/li\u003e\n\u003cli\u003eThe 2-ton and 3-ton models at 17-1\/2 in (HC24MCB021H1, HC36MBB021H1) are reserved for narrow furnaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll use R-454B with a TXV metering device.\u003c\/p\u003e\n\n\u003ch3\u003eShape, cabinet and weight\u003c\/h3\u003e\n\u003cp\u003eThe coil keeps the A shape, with two sloped faces joined at the top. Its insulated cabinet measures 21 × 27-1\/2 × 21 in and weighs 58 lb, with multi-position installation provided by the manufacturer: vertical, horizontal left or right. Inside, the refrigerant evaporates, removes heat from the air and causes condensation, which the pan and the drain carry away.\u003c\/p\u003e\n\n\u003ch3\u003eHC60MBC021H1 specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003enominal size: 5 tons (60,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003e3\/8 in liquid connection, 7\/8 in suction connection;\u003c\/li\u003e\n\u003cli\u003econdensate drain: two 3\/4 in female pipe thread (FPT) connections, at the front left and front right;\u003c\/li\u003e\n\u003cli\u003ebuilt-in R-454B leak detector, factory installed;\u003c\/li\u003e\n\u003cli\u003ewarranty: 10 years compressor, 10 years parts; registration required; conditions apply (Samsung quote).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HA00A00203H1 mitigation controller is mandatory and sold separately; we add it to the quote as a matter of course.\u003c\/p\u003e\n\n\u003ch3\u003eWhat Samsung publishes about outdoor units of this size\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHylex Premium 4-ton and 5-ton: cooling from -20 to 50 °C, heating down to -25 °C, full heating capacity at -10 °C;\u003c\/li\u003e\n\u003cli\u003eHylex Standard: cooling from -20 to 50 °C; not ENERGY STAR certified;\u003c\/li\u003e\n\u003cli\u003einverter-driven twin rotary BLDC compressor;\u003c\/li\u003e\n\u003cli\u003epiping: maximum length of 164 ft (50 m), maximum elevation difference of 98 ft (30 m).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat you gain compared with all-electric heating\u003c\/h3\u003e\n\u003cp\u003eAn electric furnace produces only as much heat as the electricity it receives. A heat pump borrows heat from the outdoor air and, in mild temperatures, returns two to three times the energy consumed. Severe cold reduces this advantage; the furnace then takes over. The coil is the meeting point between that heat and the air in your duct system.\u003c\/p\u003e\n\n\u003ch3\u003eThe work of our crews\u003c\/h3\u003e\n\u003cp\u003eAirGreen, a heating and cooling company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasurement of the furnace, check of the blower and the panel;\u003c\/li\u003e\n\u003cli\u003einstallation of the cabinet and sealing of the ducts;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit, brazed piping, nitrogen test, vacuum;\u003c\/li\u003e\n\u003cli\u003edrain, thermostat, start-up and airflow adjustment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAn example of reasoning, with no invented figures\u003c\/h3\u003e\n\u003cp\u003eImagine a large suburban house with a finished basement and a 21 in furnace. The owner mainly wants even summer comfort upstairs and on the main floor, and would like to reduce furnace use in winter. If the calculation shows the load stays close to the smaller-capacity pairing, they will take the AC048FCUPCG\/AA and enjoy a higher efficiency rating. If the house loses a lot of heat or has large glazed areas, we will go with the AC060FCUPCG\/AA.\u003c\/p\u003e\n\u003cp\u003eIn both cases, the same coil stays in the plenum; only the outdoor unit changes.\u003c\/p\u003e\n\u003ch3\u003eThe point never to forget: R-454B\u003c\/h3\u003e\n\u003cp\u003eThe coil and the outdoor unit share the same refrigerant, and the leak detector built in at the factory monitors the circuit. The separately sold mitigation controller completes this safeguard. For that reason, this coil is not matched with an old air conditioner: we install the complete system.\u003c\/p\u003e\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe paired Samsung system appears on Hydro-Québec’s list of eligible heat pumps. The amount depends on the installation date and your situation: we check it against the official list at the time of the quote and prepare the application with you.\u003c\/p\u003e\n\n\u003ch3\u003eMaintenance and access\u003c\/h3\u003e\n\u003cp\u003eThe filter should be changed regularly and the condensate drain must stay clear. At start-up, we show you where the filter, the drain and the mitigation controller are, so you know what to expect. A coil that breathes well keeps its performance from one season to the next.\u003c\/p\u003e\n\u003ch3\u003eNoise and location\u003c\/h3\u003e\n\u003cp\u003eWhichever unit is chosen, we place it on a stable base, away from bedrooms and neighbouring windows, with enough clearance for air. We talk about it at the visit and mark the spot together, so that nothing surprises you on installation day.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this coil provide heating?\u003c\/strong\u003e Yes, with a heat pump. With a central air conditioner, it provides cooling only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my air conditioner?\u003c\/strong\u003e Generally no: R-454B requires the unit specified by the manufacturer; we install the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still useful?\u003c\/strong\u003e Yes, it serves as backup below the threshold set with you.\u003c\/p\u003e\n\n\u003ch3\u003eA 5-ton Samsung coil, installed by AirGreen\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Samsung system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Samsung","offers":[{"title":"Default Title","offer_id":68401583718692,"sku":"HC60MBC021H1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_SAMSUNG_HYLEX_HC60MBC021H1_00_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795724091","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-samsung-hc60mbc021h1-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}