{"product_id":"serpentin-devaporateur-trane-4txca002rs3-a-1-5-a-2-tonnes","title":"TRANE 4TXCA002RS3 Evaporator A-Coil | 1.5 to 2 Tons","description":"\u003ch2\u003e4TXCA002RS3: the smallest Trane coil in the series, for a 14-1\/2 in furnace\u003c\/h2\u003e\n\u003cp\u003eIn a Longueuil townhouse, a compact Laval bungalow or a Montreal plex, the furnace often sits in a closet or a corner of the basement, and every inch counts. The \u003cstrong\u003eTrane 4TXCA002RS3 evaporator coil\u003c\/strong\u003e is built for exactly that situation: a cased A-coil rated \u003cstrong\u003e1.5 to 2 tons\u003c\/strong\u003e (24,000 BTU\/h), 14-1\/2 in wide and 17-1\/2 in tall. It runs on \u003cstrong\u003eR-410A refrigerant\u003c\/strong\u003e and belongs to the Trane 4TXC line.\u003c\/p\u003e\n\u003cp\u003eWe install it across the whole region: Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eWhat this coil actually does\u003c\/h3\u003e\n\u003cp\u003eThe coil is the part that exchanges heat with the air in your home. Refrigerant arrives from the outdoor unit, evaporates inside the tubes and cools the air that the furnace blower pushes through the assembly. Without it, the outdoor unit has nothing to feed indoors.\u003c\/p\u003e\n\u003cp\u003eIf the outdoor unit is a heat pump, the same coil works in the other direction in winter. It becomes the point where the heat captured outside is released into the air in your ducts. One piece of indoor equipment, then, for two seasons.\u003c\/p\u003e\n\n\u003ch3\u003eA compact home, a compact size\u003c\/h3\u003e\n\u003cp\u003eThe 1.5 to 2 ton size is meant for smaller living spaces: row houses, older bungalows, duplex or triplex floors that each have their own furnace. An oversized unit shuts off before it has dried the air enough. The result is a correct temperature but a damp, muggy feel. In a small volume, that flaw shows up quickly.\u003c\/p\u003e\n\u003cp\u003eThat is why we always start from a load calculation rather than a habit. If the calculation points to a larger size, we tell you frankly and steer you toward a neighbouring model in the series.\u003c\/p\u003e\n\n\u003ch3\u003eThe dimensions that matter on the installation plan\u003c\/h3\u003e\n\u003cp\u003eHere is what Trane publishes for this model, presented the way we read it on the job site:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e14-1\/2 in wide, to compare with the width of the furnace plenum;\u003c\/li\u003e\n\u003cli\u003e17-1\/2 in tall and 21-1\/2 in deep, which settles whether the space above the furnace is enough;\u003c\/li\u003e\n\u003cli\u003enet weight of 34 lb, easy to handle on a narrow staircase;\u003c\/li\u003e\n\u003cli\u003e3\/8 in liquid line connection and 3\/4 in suction line connection;\u003c\/li\u003e\n\u003cli\u003e3\/4 in NPT condensate drain;\u003c\/li\u003e\n\u003cli\u003epossible positions: upflow, downflow or horizontal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe coil comes in an insulated cabinet. It therefore goes onto the furnace in one piece, with no need to build a box around it.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing between the 4TXCA002RS3 and its neighbours in the series\u003c\/h3\u003e\n\u003cp\u003eThe series has ten models, grouped into four widths: 14-1\/2 in, 17-1\/2 in, 21 in and 24-1\/2 in. The model shown here is one of the two narrowest and covers the smallest capacity range, 1.5 to 2 tons. Here is how to place it.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e4TXCA032RS3\u003c\/strong\u003e: the same 14-1\/2 in width, but a range of 1.5 to 3 tons. If the home is small today but an addition is possible, this neighbour leaves more room.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e4TXCB003RS3\u003c\/strong\u003e: a range of 1.5 to 3 tons on a 17-1\/2 in width. It suits a wider furnace.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e4TXCB004RS3\u003c\/strong\u003e: 2 to 3.5 tons, also in 17-1\/2 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e4TXCC005RS3\u003c\/strong\u003e: 2 to 4 tons, in 21 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll of them share R-410A refrigerant and the TXV expansion valve. The real question is therefore the width of your furnace, then the load of the home. The rest follows.\u003c\/p\u003e\n\n\u003ch3\u003eThe A shape and the TXV expansion valve\u003c\/h3\u003e\n\u003cp\u003eThe two sloped faces of the coil meet at the top. Air rises through the centre and passes through both surfaces. This layout suits upflow furnaces well, which are very common in Quebec housing.\u003c\/p\u003e\n\u003cp\u003eThe TXV adjusts the flow of refrigerant entering the coil according to the load at that moment. It avoids flooding the tubes when demand is low and starving the end of the coil when demand is high.\u003c\/p\u003e\n\n\u003ch3\u003eElectric furnace, add-on heat pump: the typical scenario\u003c\/h3\u003e\n\u003cp\u003eMany of our customers in small homes heat with electric baseboards or an electric furnace. Adding a heat pump to the existing furnace changes the picture without redoing the duct network: the blower, the filters and the vents stay in place. The furnace keeps a backup role when the outdoor temperature drops below the threshold we set with you.\u003c\/p\u003e\n\u003cp\u003eAnother common scenario is replacing an old central air conditioner whose coil is worn out. In that case, the new assembly goes in as a single piece, with the matching outdoor unit.\u003c\/p\u003e\n\n\u003ch3\u003eMatching with the outdoor unit and the AHRI number\u003c\/h3\u003e\n\u003cp\u003eA coil on its own has no efficiency rating. The ratings you see on a quote describe a matched system: this coil, that outdoor unit, linked by an AHRI number. We verify that number before ordering, so that the figures promised are the ones you will get.\u003c\/p\u003e\n\u003cp\u003eTrane also states that its R-410A coils in this family are intended for replacement, not for a new installation (reference COR-PSD012A-EN). In other words, they suit mostly the case where a system using the same refrigerant is already in place. We confirm this during the visit.\u003c\/p\u003e\n\n\u003ch3\u003eOur installation method, from the plenum to the thermostat\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe measure the furnace and check the blower and the electrical panel.\u003c\/li\u003e\n\u003cli\u003eWe set the coil in the plenum, with an insulated transition built on site if the width does not match, then we seal the joints.\u003c\/li\u003e\n\u003cli\u003eWe install the outdoor unit on a stand, braze the piping, run the nitrogen pressure test and pull a vacuum.\u003c\/li\u003e\n\u003cli\u003eWe connect the condensate drain and the thermostat.\u003c\/li\u003e\n\u003cli\u003eWe set the airflow and explain how everything works in your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently asked questions about this model\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan it heat?\u003c\/strong\u003e Yes, with a heat pump. With a central air conditioner, it only cools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my current outdoor unit?\u003c\/strong\u003e Generally not: the coil and the outdoor unit are chosen together, with the same refrigerant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy furnace is not exactly 14-1\/2 in. What can I do?\u003c\/strong\u003e We take measurements and, if needed, build an insulated transition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still useful?\u003c\/strong\u003e Yes, it keeps its blower and takes over in extreme cold.\u003c\/p\u003e\n\n\u003ch3\u003eIncentives and eligibility\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs apply to the complete system, not to the coil alone. When we prepare the quote, we check the match on the official list according to the installation date, then tell you what applies to your project.\u003c\/p\u003e\n\n\u003ch3\u003eTrane and AirGreen\u003c\/h3\u003e\n\u003cp\u003eTrane, a Trane Technologies brand, makes residential and commercial heating and cooling equipment. AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years; our refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to check before placing the order\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe refrigerant of the existing system must be R-410A.\u003c\/li\u003e\n\u003cli\u003eThe width of the furnace, the clearance above it and the capacity of the blower.\u003c\/li\u003e\n\u003cli\u003eThe certified match with the outdoor unit, confirmed by its AHRI number.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eGet your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Trane system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Trane","offers":[{"title":"Default Title","offer_id":68402716901668,"sku":"4TXCA002RS3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_TRANE_4TXC_4TXCA002RS3_00_1_5_A_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766268","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-trane-4txca002rs3-a-1-5-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}