{"product_id":"serpentin-devaporateur-trane-4txcc009rs3-a-3-5-a-5-tonnes","title":"TRANE 4TXCC009RS3 Evaporator A-Coil | 3.5 to 5 Tons","description":"\u003ch2\u003e4TXCC009RS3: up to 5 tons, the tallest 21 in cabinet in the series\u003c\/h2\u003e\n\u003cp\u003eLarge homes raise a simple question: how do you fit a lot of capacity into a single unit without requiring an oversized furnace? The \u003cstrong\u003eTrane 4TXCC009RS3 coil\u003c\/strong\u003e answers by keeping the 21 in width and gaining height: 30-3\/4 in, for a depth of 21-1\/2 in. It covers \u003cstrong\u003e3.5 to 5 tons\u003c\/strong\u003e (60,000 BTU\/h), cased, on \u003cstrong\u003eR-410A refrigerant\u003c\/strong\u003e with a TXV expansion valve. Its net weight is 70 lb.\u003c\/p\u003e\n\n\u003ch3\u003eChecklist before ordering it\u003c\/h3\u003e\n\u003cp\u003eThe bigger the unit, the more small mistakes cost. Here is the list we follow at every visit.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eClear height.\u003c\/strong\u003e The 30-3\/4 in cabinet must fit above the plenum, with the access clearance needed for maintenance.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWidth.\u003c\/strong\u003e The furnace must be 21 in wide, otherwise we build an insulated transition.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBlower.\u003c\/strong\u003e It must be able to move the volume of air that a capacity of this order demands.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eElectrical panel.\u003c\/strong\u003e The matching outdoor unit draws current; we check the available capacity.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDucts.\u003c\/strong\u003e Their cross-section must be sufficient; undersized ducts choke a large system.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRefrigerant.\u003c\/strong\u003e The existing system must use R-410A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA range of 3.5 to 5 tons, for whom?\u003c\/h3\u003e\n\u003cp\u003eThis model targets homes whose cooling load exceeds 3 tons: large cottages, three-level homes, residences with sunrooms or cathedral ceilings in Laval, on the North Shore or in Montreal. It also targets properties in Longueuil and on the South Shore where a single system serves a large area.\u003c\/p\u003e\n\u003cp\u003eA high capacity does not mean better comfort. If the home is better insulated than you think, a lower range is more than enough. We show it by calculation, not by intuition.\u003c\/p\u003e\n\n\u003ch3\u003eCompared with its 21 in and 24-1\/2 in neighbours\u003c\/h3\u003e\n\u003cp\u003eIn the 21 in width, the \u003cstrong\u003e4TXCC007RS3\u003c\/strong\u003e covers 3 to 4 tons with a shorter cabinet, and the \u003cstrong\u003e4TXCC005RS3\u003c\/strong\u003e covers 2 to 4 tons. The 4TXCC009RS3 is the one that extends the range up to 5 tons.\u003c\/p\u003e\n\u003cp\u003eWith the same 3.5 to 5 ton range, but 24-1\/2 in wide, the \u003cstrong\u003e4TXCD008RS3\u003c\/strong\u003e and \u003cstrong\u003e4TXCD010RS3\u003c\/strong\u003e also exist. If your furnace is wider than 21 in, those are the ones to look at. If it is narrower, the \u003cstrong\u003e4TXCB006RS3\u003c\/strong\u003e, at 2 to 5 tons, offers the same capacity ceiling on 17-1\/2 in.\u003c\/p\u003e\n\n\u003ch3\u003eWeight and handling\u003c\/h3\u003e\n\u003cp\u003eAt 70 lb, this coil is not handled by one person on a basement staircase. We carry it up with two people, with straps if the passage is narrow. The cabinet is set on the furnace, levelled, then sealed before the piping is connected. A poorly supported coil ends up deforming the plenum, hence the importance of this step.\u003c\/p\u003e\n\n\u003ch3\u003eConnections, drain and positions\u003c\/h3\u003e\n\u003cp\u003e3\/8 in liquid line, 7\/8 in suction line, 3\/4 in NPT condensate drain. The published positions are upflow, downflow and horizontal. A large coil produces a lot of water in humid weather: the drain must slope without dips, and a safety pan is sometimes advised above a finished room.\u003c\/p\u003e\n\n\u003ch3\u003eHigh capacity, but not at any price\u003c\/h3\u003e\n\u003cp\u003eIt is tempting to believe that a 5 ton unit will cool a large home better than a 4 ton unit. In practice, a system that is too big runs in short cycles, leaves the air humid and puts more stress on the components. The right size is the one the load calculation confirms.\u003c\/p\u003e\n\u003cp\u003eThe 3.5 to 5 ton range of this coil exists to offer a choice of outdoor units, not to encourage oversizing. If your calculation lands at 3.5 tons, that is the unit we will propose, with the same cabinet.\u003c\/p\u003e\n\u003ch3\u003eThe homeowner's point of view\u003c\/h3\u003e\n\u003cp\u003eAfter installation, the home feels more even. The upstairs rooms, often the hardest to cool, regain a comfort level close to that of the ground floor. The blower noise is steadier, without jolts. And humidity drops, which makes nights easier to live through during heat waves.\u003c\/p\u003e\n\u003cp\u003eThese are effects that a well-sized, well-installed system produces naturally. They do not come from the brand alone, but from the whole: coil, outdoor unit, ducts, airflow adjustment.\u003c\/p\u003e\n\u003ch3\u003eMaintenance and service life\u003c\/h3\u003e\n\u003cp\u003eA large coil demands the same discipline as a small one: clean filter, clear drain, yearly inspection of the connections. We recommend a check before each cooling season. It lets us spot a blocked drain, a weeping fitting or a buildup of dust on the fins before they cause damage.\u003c\/p\u003e\n\u003ch3\u003eHeat pump and the role of the furnace\u003c\/h3\u003e\n\u003cp\u003eWith a heat pump, this coil contributes to heating in addition to cooling, using the home's ducts. The furnace keeps its blower, its filters and its backup role when the outdoor temperature drops below the threshold programmed with you. With a central air conditioner, the furnace heats as before and the coil is limited to cooling.\u003c\/p\u003e\n\n\u003ch3\u003eEfficiency: what the AHRI number says\u003c\/h3\u003e\n\u003cp\u003eEfficiency is read on the system, not on the coil. The AHRI number links the coil to a specific outdoor unit and sets the ratings that count. We verify it before ordering. Trane also states that the R-410A coils in this family are for replacement only (COR-PSD012A-EN).\u003c\/p\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec takes the complete system into account. We look at the official list when we prepare the quote, according to the installation date, and indicate what applies to your file.\u003c\/p\u003e\n\n\u003ch3\u003eOur work, from the plenum to the thermostat\u003c\/h3\u003e\n\u003cp\u003eWe measure, check the blower and the panel, set the cabinet and seal the connections. We install the outdoor unit, braze the piping, run the nitrogen test, pull the vacuum, connect the drain and the thermostat, then adjust the airflow. Finally, we go over the operation with you.\u003c\/p\u003e\n\n\u003ch3\u003eAn example visit for a large home\u003c\/h3\u003e\n\u003cp\u003eIn a large North Shore cottage, we always start with the basement: the furnace, its plenum, the ceiling height. Then we go upstairs to feel the air at the vents, spot the rooms that lag behind and examine the return air. We finish outside, at the planned spot for the unit.\u003c\/p\u003e\n\u003cp\u003eThis round takes about an hour. It gives us what we need to calculate the load, check that the 30-3\/4 in tall cabinet fits and decide whether the ducts need adjustments. We then provide a detailed written quote.\u003c\/p\u003e\n\u003ch3\u003eQuestions our customers ask at the end of the visit\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need to be away on the day of the work?\u003c\/strong\u003e No, but we cut power to the furnace for part of the day.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo we need to clear the space around the furnace?\u003c\/strong\u003e Yes, a clear path speeds up the job and protects your belongings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a surprise turns up?\u003c\/strong\u003e We show it to you, explain the options and wait for your agreement before changing the quote.\u003c\/p\u003e\n\u003ch3\u003eQuick answers\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs it made for a new home?\u003c\/strong\u003e Trane intends it for replacement; we discuss the system in place.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need to change my ducts?\u003c\/strong\u003e Not necessarily: we check whether they are adequate for the airflow of the system.\u003c\/p\u003e\n\n\u003ch3\u003eAbout AirGreen and Trane\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. Trane is a Trane Technologies brand.\u003c\/p\u003e\n\n\u003ch3\u003eNext step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Trane system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Trane","offers":[{"title":"Default Title","offer_id":68402708676900,"sku":"4TXCC009RS3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_TRANE_4TXC_4TXCC009RS3_00_3_5_A_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766269","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-trane-4txcc009rs3-a-3-5-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}