{"product_id":"serpentin-devaporateur-trane-4txcd008rs3-a-3-5-a-5-tonnes","title":"TRANE 4TXCD008RS3 Evaporator A-Coil | 3.5 to 5 Tons","description":"\u003ch2\u003eTrane 4TXCD008RS3: the 24-1\/2 in width for large furnaces\u003c\/h2\u003e\n\u003cp\u003eAt the top of the Trane 4TXC series, the width goes up to 24-1\/2 in. The \u003cstrong\u003e4TXCD008RS3\u003c\/strong\u003e is the shorter of the two models of this width: a cased A-coil of \u003cstrong\u003e3.5 to 5 tons\u003c\/strong\u003e (60,000 BTU\/h) on \u003cstrong\u003eR-410A refrigerant\u003c\/strong\u003e, with a TXV expansion valve, 24-1\/2 in wide, 26-3\/4 in tall and 21-1\/2 in deep. It weighs 64 lb net.\u003c\/p\u003e\n\n\u003ch3\u003eWhy width matters so much\u003c\/h3\u003e\n\u003cp\u003eA coil that matches the width of the furnace lets air through without choking it. At 24-1\/2 in, this model is meant for large furnaces, often installed in the more spacious homes of Laval, the North Shore or the South Shore, as well as in some blower cabinets in Montreal or Longueuil.\u003c\/p\u003e\n\n\u003ch3\u003eHead to head with the 4TXCD010RS3\u003c\/h3\u003e\n\u003cp\u003eThe two 24-1\/2 in models cover the same range, 3.5 to 5 tons. What separates them is height and weight: the 4TXCD008RS3 is 26-3\/4 in tall and weighs 64 lb; the \u003cstrong\u003e4TXCD010RS3\u003c\/strong\u003e is taller and heavier. If the clearance above the furnace is limited, the first is easier to fit. If space is plentiful, the second is also possible.\u003c\/p\u003e\n\u003cp\u003eOur role is to measure first, then decide. A cabinet that is too tall is caught before the order, not on the day of the work.\u003c\/p\u003e\n\n\u003ch3\u003eAnd compared with the 21 in models?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e4TXCC009RS3\u003c\/strong\u003e also offers 3.5 to 5 tons, but at 21 in wide. So it is not capacity that guides you here: it is the furnace. If it measures 21 in, the 4TXCC009RS3 is the one. If it measures 24-1\/2 in, the 4TXCD008RS3 avoids a transition. A 17-1\/2 in furnace, finally, points to the 4TXCB006RS3, at 2 to 5 tons.\u003c\/p\u003e\n\n\u003ch3\u003eThe technical data in brief\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 3.5 to 5 tons, or 60,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003eLiquid line connection: 3\/8 in. Suction line connection: 7\/8 in.\u003c\/li\u003e\n\u003cli\u003eCondensate drain: 3\/4 in NPT.\u003c\/li\u003e\n\u003cli\u003ePositions: upflow, downflow, horizontal.\u003c\/li\u003e\n\u003cli\u003eExpansion device: TXV.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA less humid summer\u003c\/h3\u003e\n\u003cp\u003eWhat strikes our customers most, after the first heat wave, is not the temperature but the humidity. A well-matched system removes water from the air before sending it back, and the clammy feeling disappears. The water collected in the pan flows out through the 3\/4 in NPT drain.\u003c\/p\u003e\n\u003cp\u003eThis assumes a system that is not oversized. That is why a load calculation comes before every proposal, including those that lead to a large coil like this one.\u003c\/p\u003e\n\n\u003ch3\u003eThree typical jobs for this model\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe large North Shore cottage.\u003c\/strong\u003e The owners want to replace an ageing central air conditioner and add a heat pump. The wide furnace takes the cabinet without a transition. The job is simple, quick, clean.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Laval home with an addition.\u003c\/strong\u003e A room was added a few years ago and the system in place struggles to keep up. The load calculation confirms the need for high capacity. The plenum has enough height: the 4TXCD008RS3 goes in without modification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Montreal plex.\u003c\/strong\u003e An owner-occupant wants to cool their unit and the one above with a single system. The shared furnace is large, the height is limited: the shortest model in the 24-1\/2 in width is the right choice.\u003c\/p\u003e\n\u003ch3\u003eWhat your blower must be able to do\u003c\/h3\u003e\n\u003cp\u003eA coil with a large surface works well only if the blower can move the matching volume of air through it. A fixed-speed blower that is too weak causes the coil to frost up; a properly adjusted blower provides a steady exchange. We check the motor, the capacitor and the selected speed before installing anything.\u003c\/p\u003e\n\u003cp\u003eIn some cases, a variable-speed motor is a good idea. We discuss it during the visit, case by case, without imposing anything.\u003c\/p\u003e\n\u003ch3\u003eHeat pump, cooling only and backup\u003c\/h3\u003e\n\u003cp\u003ePaired with a heat pump, this coil serves for heating and cooling with the existing ducts. The furnace keeps its blower and its filters, and takes over below the threshold we program with you. Paired with a central air conditioner, it provides cooling only.\u003c\/p\u003e\n\n\u003ch3\u003eThe AHRI number rather than a rating\u003c\/h3\u003e\n\u003cp\u003eEfficiency ratings belong to the matched system, not to the coil. An AHRI number links them. We confirm it before the order. Trane adds that its R-410A coils in this family are for replacement only (COR-PSD012A-EN): we therefore check your current system.\u003c\/p\u003e\n\n\u003ch3\u003eHow the work unfolds\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring the furnace, the blower and the electrical panel.\u003c\/li\u003e\n\u003cli\u003eSetting the cabinet, joints sealed, transition if needed.\u003c\/li\u003e\n\u003cli\u003eOutdoor unit on a stand, piping brazed, nitrogen test, vacuum.\u003c\/li\u003e\n\u003cli\u003eDrain and thermostat connected.\u003c\/li\u003e\n\u003cli\u003eAirflow adjustment, demonstration at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA word on noise\u003c\/h3\u003e\n\u003cp\u003eA large coil in a large furnace does not necessarily make more noise: it all depends on the airflow and the condition of the ducts. A well-balanced system produces a steady, almost imperceptible flow of air. If you hear a whistle at the vents, it is usually a sign of a duct that is too narrow or a closed register. We measure the pressure before concluding and correct as needed.\u003c\/p\u003e\n\u003cp\u003eThe outdoor unit is placed away from bedroom windows and on a stable base. A vibrating support transmits noise to the structure; we avoid it by choosing the location well.\u003c\/p\u003e\n\u003ch3\u003eA quote you can read, line by line\u003c\/h3\u003e\n\u003cp\u003eEach quote we provide states the model number of the coil, that of the matched outdoor unit, the AHRI number of the system and the list of the work included. You can compare it, line by line, with another contractor's. If a piece of information is missing elsewhere, it is a good chance to ask the question.\u003c\/p\u003e\n\u003ch3\u003eQuestions our customers ask at the end of the visit\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need to be away on the day of the work?\u003c\/strong\u003e No, but we cut power to the furnace for part of the day.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo we need to clear the space around the furnace?\u003c\/strong\u003e Yes, a clear path speeds up the job and protects your belongings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a surprise turns up?\u003c\/strong\u003e We show it to you, explain the options and wait for your agreement before changing the quote.\u003c\/p\u003e\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs apply to the complete system. We confirm the match on the official list according to the installation date and tell you what applies.\u003c\/p\u003e\n\n\u003ch3\u003eTo check before deciding\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerant of the system in place: R-410A.\u003c\/li\u003e\n\u003cli\u003eFurnace width: 24-1\/2 in.\u003c\/li\u003e\n\u003cli\u003eClear height for a 26-3\/4 in cabinet.\u003c\/li\u003e\n\u003cli\u003eCapacity of the blower and the electrical panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA local company\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. Trane is a Trane Technologies brand.\u003c\/p\u003e\n\n\u003ch3\u003eEstimate and financing\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Trane system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Trane","offers":[{"title":"Default Title","offer_id":68402708087076,"sku":"4TXCD008RS3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_TRANE_4TXC_4TXCD008RS3_00_3_5_A_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766269","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-trane-4txcd008rs3-a-3-5-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}