{"product_id":"serpentin-devaporateur-trane-5mxca003ac3hca-a-1-5-a-3-tonnes","title":"TRANE 5MXCA003AC3HCA Evaporator A-Coil | 1.5 to 3 Tons","description":"\u003ch2\u003e5MXCA003AC3HCA: the narrowest of the Trane 5MXC series, made for compact furnaces\u003c\/h2\u003e\n\u003cp\u003eIn a row house in Longueuil or a small bungalow in Laval, the furnace is often squeezed into a basement corner between a water heater and a concrete wall. The \u003cstrong\u003eTrane 5MXCA003AC3HCA evaporator coil\u003c\/strong\u003e was designed for exactly that kind of space: at 14-1\/2 in wide, it is the narrowest of the eight models we sell in this series. It covers a 1.5 to 3 ton size (36,000 BTU\/h), runs on \u003cstrong\u003eR-454B\u003c\/strong\u003e and comes in an insulated cabinet.\u003c\/p\u003e\n\u003cp\u003eWe install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, always with the outdoor unit that matches it.\u003c\/p\u003e\n\n\u003ch3\u003eWhat an evaporator coil actually does\u003c\/h3\u003e\n\u003cp\u003ePicture a radiator running in reverse. Instead of heating the air, its aluminum and copper tubes cool it: the refrigerant arrives cold from the outdoor unit, evaporates inside the tubes and absorbs heat from the air that the furnace blower sends across it. Moisture in the air condenses on the fins, drips into a pan and runs off to the drain.\u003c\/p\u003e\n\u003cp\u003eWithout this component, an outdoor unit is useless: it is the link between the refrigerant and the air in your rooms.\u003c\/p\u003e\n\n\u003ch3\u003eA width of 14-1\/2 in: the advantage and the constraint\u003c\/h3\u003e\n\u003cp\u003eThe coil has to fit the top of the furnace. Too wide, and it overhangs; too narrow, and air leaks around the cabinet. At 14-1\/2 in wide, the 5MXCA003AC3HCA suits the slimmest units. Its full dimensions are 14-1\/2 × 20 × 21 in (width, height, depth) with a net weight of 44 lb: a package one technician can carry alone down a narrow basement staircase.\u003c\/p\u003e\n\u003cp\u003eThe constraint is that this width is not universal. Before any order, we measure your furnace. If the gap is small, we build an insulated transition on site rather than force a part that does not fit.\u003c\/p\u003e\n\n\u003ch3\u003eAn air conditioning system, or a heat pump that keeps the furnace in reserve\u003c\/h3\u003e\n\u003cp\u003ePaired with a central air conditioner, this coil provides summer cooling. Paired with a heat pump, it does the opposite as well: in winter the cycle reverses and the refrigerant delivers the heat collected outdoors into your ducts. This is the \"add-on\" approach: the furnace stays in place, with its blower, filters and ductwork, and becomes your backup heat.\u003c\/p\u003e\n\u003cp\u003eThe temperature at which the furnace takes over is set with you at commissioning. That choice depends on your comfort, your insulation and your electricity bill.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing between the 5MXCA003AC3HCA and its seven siblings\u003c\/h3\u003e\n\u003cp\u003eThe whole series shares the same refrigerant (R-454B), the same TXV and the same type of cabinet. What changes is the width and the capacity range:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e5MXCA003AC3HCA\u003c\/strong\u003e (this one): 14-1\/2 in wide, 1.5 to 3 tons;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5MXCB004AC3HCA\u003c\/strong\u003e: 17-1\/2 in, 1.5 to 3 tons;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5MXCB006AC3HCA\u003c\/strong\u003e: 17-1\/2 in, 1.5 to 3.5 tons;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5MXCC005AC3HCA\u003c\/strong\u003e: 21 in, 1.5 to 3 tons;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5MXCC007AC3HCA\u003c\/strong\u003e: 21 in, 1.5 to 3.5 tons;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5MXCC009AC3HCA\u003c\/strong\u003e: 21 in, 3 to 5 tons;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5MXCD008AC3HCA\u003c\/strong\u003e: 24-1\/2 in, 3 to 3.5 tons;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5MXCD010AC3HCA\u003c\/strong\u003e: 24-1\/2 in, 3 to 5 tons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA simple rule: start with the width of the furnace, then look at capacity. If your unit is narrow and your need falls between 1.5 and 3 tons, this model is the right candidate. If the furnace is wider, a wider coil will avoid the transition.\u003c\/p\u003e\n\n\u003ch3\u003eWhat Trane publishes about matching\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer's documents state that these coils are AHRI certified with Trane, American Standard, RunTru and Ameristar outdoor units (COR-PSD013B-EN). On the other hand, no ENERGY STAR match is published under the 5MXC prefix. We would rather say so plainly than let you believe otherwise.\u003c\/p\u003e\n\u003cp\u003eThe coil has no efficiency rating on its own. Seasonal ratings belong to the matched system, identified by an AHRI number. Before ordering, we check that number in the official directory, so the figures in your quote match those of your installation.\u003c\/p\u003e\n\n\u003ch3\u003e5MXCA003AC3HCA specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil, 5MXC series;\u003c\/li\u003e\n\u003cli\u003enominal size: 1.5 to 3 tons (36,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003eexpansion device: TXV;\u003c\/li\u003e\n\u003cli\u003epositions: multipoise (upflow, downflow, horizontal left or right);\u003c\/li\u003e\n\u003cli\u003eliquid connection 3\/8 in, suction connection 3\/4 in;\u003c\/li\u003e\n\u003cli\u003econdensate drain: 3\/4 in NPT;\u003c\/li\u003e\n\u003cli\u003edimensions: 14-1\/2 × 20 × 21 in, net weight 44 lb;\u003c\/li\u003e\n\u003cli\u003eleak detection: the dimensional drawing (COR-PSD013B-EN) shows the location of a refrigerant sensor (\"R454B Refrigerant Mitigation Sensor\", MCB kit); the document does not describe its function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShape, expansion and positions\u003c\/h3\u003e\n\u003cp\u003eThe A-coil forms a roof with two slopes: air rises through the centre of the furnace and passes through both faces. The TXV adjusts the refrigerant flow to the load, which steadies the discharge temperature. Because the unit is multipoise, it can be installed just as well on an upflow furnace as on a furnace lying on its side in an attic.\u003c\/p\u003e\n\n\u003ch3\u003eAn insulated cabinet saves time and keeps the air better contained\u003c\/h3\u003e\n\u003cp\u003eThis model arrives already housed in its insulated casing. In practical terms, nobody has to build a box around the coil out of sheet metal and insulation: we set it, connect it and seal it. In a space as tight as a row-house basement, every hour not spent cutting sheet metal is an hour less dust and noise for the family. A factory-built cabinet also limits air leaks between the furnace and the coil, and the insulation keeps the casing from beading with droplets when the air is humid in July.\u003c\/p\u003e\n\u003cp\u003eThe 3\/8 in (liquid) and 3\/4 in (suction) connections are the ones we braze to the outdoor unit's piping; the 3\/4 in NPT drain takes a tube that runs to a drain or a condensate pump, depending on your basement layout.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we do on installation day\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMeasuring the furnace, checking the blower and the electrical panel.\u003c\/li\u003e\n\u003cli\u003eInstalling the cabinet in the plenum, a custom transition if needed, sealing the duct joints.\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a pad or bracket, brazed piping, nitrogen leak test, vacuum.\u003c\/li\u003e\n\u003cli\u003eConnecting the condensate drain and the thermostat.\u003c\/li\u003e\n\u003cli\u003eCommissioning, airflow adjustment, and a walk-through with the household.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eAirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Refrigeration, ventilation and electrical work is carried out under our RBQ licence 5645-9605-01.\u003c\/p\u003e\n\n\u003ch3\u003eThree checks before you buy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil and the outdoor unit must use the same refrigerant, R-454B, and be installed together.\u003c\/li\u003e\n\u003cli\u003eThe furnace must measure about 14-1\/2 in and deliver enough air: the blower is responsible for the system's airflow.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply only to the certified match.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my old outdoor air conditioner?\u003c\/strong\u003e Generally not. The coil requires the unit specified by the manufacturer, with the same refrigerant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy furnace is wider: what then?\u003c\/strong\u003e We measure it and, if needed, build an insulated transition on site.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat if I only have an air conditioner?\u003c\/strong\u003e Then the coil only cools; heating requires a heat pump.\u003c\/p\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eFinancial assistance depends on the complete system, never on the coil alone. We check Hydro-Québec's official list against your installation date and tell you what applies.\u003c\/p\u003e\n\n\u003ch2\u003eA Trane 1.5 to 3 ton coil, installed by AirGreen\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBook a free estimate visit: we measure the furnace, look at the electrical service and give you a written quote for the complete system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e lets you spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Trane","offers":[{"title":"Default Title","offer_id":68402716967204,"sku":"5MXCA003AC3HCA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_TRANE_5MXC_5MXCA003AC3HCA_00_1_5_A_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766274","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-trane-5mxca003ac3hca-a-1-5-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}