{"product_id":"serpentin-devaporateur-trane-5mxcb004ac3hca-a-1-5-a-3-tonnes","title":"TRANE 5MXCB004AC3HCA Evaporator A-Coil | 1.5 to 3 Tons","description":"\u003ch2\u003eTrane 5MXCB004AC3HCA: a 17-1\/2 in coil for the mid-width furnace\u003c\/h2\u003e\n\u003cp\u003eWhen a customer in Laval calls us to \"add air conditioning\" to their home, the first question is not capacity but: how wide is the furnace? The \u003cstrong\u003e5MXCB004AC3HCA\u003c\/strong\u003e, a cased Trane evaporator coil, answers a very common reality in Greater Montreal, that of mid-sized furnaces. It is 17-1\/2 in wide, covers 1.5 to 3 tons (36,000 BTU\/h) and uses \u003cstrong\u003eR-454B\u003c\/strong\u003e refrigerant.\u003c\/p\u003e\n\n\u003ch3\u003eThree questions to ask before choosing it\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\u003cstrong\u003eHow wide is my furnace?\u003c\/strong\u003e Around 17-1\/2 in, the cabinet fits well, with no transition piece.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDo I have room in height?\u003c\/strong\u003e This model is 20 in tall, which leaves some margin under a low basement ceiling.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDo I only want cooling, or heating as well?\u003c\/strong\u003e The coil serves both, depending on the outdoor unit that goes with it.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eIf you can answer these three questions, you are halfway there. We do the other half during the visit.\u003c\/p\u003e\n\n\u003ch3\u003eThe exact role of the coil in the home\u003c\/h3\u003e\n\u003cp\u003eThe coil sits in the plenum, just above the furnace. Return air, drawn from the rooms, passes through its fins before heading back out through the ducts. In summer, the refrigerant circulating in its tubes cools and dehumidifies that air; the collected water leaves through a 3\/4 in NPT drain. The thermostat controls the whole thing: a single device to set.\u003c\/p\u003e\n\n\u003ch3\u003eMatching with the outdoor unit: a duo, not a solo\u003c\/h3\u003e\n\u003cp\u003eA coil from this range is never bought alone and blind. It is matched with a Trane outdoor unit of the same capacity and the same refrigerant, and it is that pair that receives an AHRI number. We confirm that number before placing the order. Trane's documents show coils AHRI certified with Trane, American Standard, RunTru and Ameristar outdoor units (COR-PSD013B-EN), and no ENERGY STAR match published under the 5MXC prefix.\u003c\/p\u003e\n\u003cp\u003eThe coil does not show an efficiency rating of its own: it is the ratings of the matched system that you should compare between two quotes.\u003c\/p\u003e\n\n\u003ch3\u003e\"Add-on\" heat pump: what remains of the furnace\u003c\/h3\u003e\n\u003cp\u003eWith a heat pump, the furnace does not disappear. It keeps its blower, its filters and your ducts, and it takes over when the outdoor temperature falls below the threshold we set with you. It is a good solution for an electrically heated home that wants to cut its consumption without redoing the whole air distribution system.\u003c\/p\u003e\n\n\u003ch3\u003e17-1\/2 in wide: where does it sit in the range?\u003c\/h3\u003e\n\u003cp\u003eThe 5MXC series offers four widths: 14-1\/2 in, 17-1\/2 in, 21 in and 24-1\/2 in. The 5MXCB004AC3HCA occupies the second step. At the same width, it has one sibling, the 5MXCB006AC3HCA, which goes up to 3.5 tons in a taller, heavier cabinet than this one (20 in tall, 46 lb).\u003c\/p\u003e\n\u003cp\u003eTo compare at the same 1.5 to 3 ton capacity, you also have the 5MXCA003AC3HCA, which is narrower (14-1\/2 in), and the 5MXCC005AC3HCA, which is wider (21 in). All three share the TXV and R-454B.\u003c\/p\u003e\n\u003cp\u003eIn short: if the furnace is 17-1\/2 in and your needs do not exceed 3 tons, the 5MXCB004AC3HCA makes sense. If you want more capacity margin at this same width, look at the 5MXCB006AC3HCA. If the furnace is narrower or wider, you need a different model.\u003c\/p\u003e\n\n\u003ch3\u003eA Quebec summer, seen from the basement\u003c\/h3\u003e\n\u003cp\u003eThe humid heat waves of July give no relief to homes that rely only on fans or window air conditioners. With a coil in the plenum, cool air is distributed through the same ducts as the heating: every bedroom benefits, including the upstairs ones that a wall unit never manages to cool. And because the coil condenses moisture on its fins, the air feels less sticky, which changes how you live through the heat.\u003c\/p\u003e\n\u003cp\u003eThat said, a system does not erase a home's weak points: a dark roof over a poorly insulated attic will always make the unit work harder. We talk about it during the visit, honestly, room by room.\u003c\/p\u003e\n\u003ch3\u003eMaintenance: what falls to the homeowner\u003c\/h3\u003e\n\u003cp\u003eA clean coil works better. The furnace filter should be changed regularly, and the condensate drain must stay clear: a plug of dirt in the pipe can make the pan overflow. We show you where to look at the end of commissioning. The rest of the maintenance, that is, cleaning the fins and checking the connections, is a technician's job.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emanufacturer and series: Trane, 5MXC;\u003c\/li\u003e\n\u003cli\u003emodel: 5MXCB004AC3HCA;\u003c\/li\u003e\n\u003cli\u003enominal size: 1.5 to 3 tons (36,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003edimensions: 17-1\/2 × 20 × 21 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 46 lb;\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003eexpansion device: TXV;\u003c\/li\u003e\n\u003cli\u003eliquid connection: 3\/8 in; suction connection: 3\/4 in;\u003c\/li\u003e\n\u003cli\u003epositions: multipoise (upflow, downflow, horizontal left or right);\u003c\/li\u003e\n\u003cli\u003erefrigerant sensor: its location appears on the dimensional drawing (COR-PSD013B-EN, \"R454B Refrigerant Mitigation Sensor\", MCB kit), but the document does not describe its function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe A-coil and the TXV\u003c\/h3\u003e\n\u003cp\u003eThe two sloped faces of the coil provide a large heat-exchange surface in a small space, and air passes through them on both sides of the peak. The TXV expansion device senses the refrigerant temperature at the outlet and opens or closes its passage accordingly: the coil therefore works with a load that varies with the heat of the day.\u003c\/p\u003e\n\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eWe come to measure first, then come back to install. In practice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ewe measure the furnace and check the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003ewe set the coil on the plenum and seal the duct connections;\u003c\/li\u003e\n\u003cli\u003ewe install the outdoor unit on a pad or bracket, braze the piping, nitrogen-test for leaks and pull a vacuum;\u003c\/li\u003e\n\u003cli\u003ewe connect the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ewe start the system, adjust the airflow and show you the unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAirGreen has been a family-run heating and cooling company in Montreal for more than fifteen years, and our refrigeration, ventilation and electrical work falls under RBQ licence 5645-9605-01. We serve Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to check before ordering\u003c\/h3\u003e\n\u003cp\u003eFirst, the refrigerant: an R-454B coil requires an R-454B outdoor unit, installed at the same time. Second, the furnace blower must be able to deliver the system's airflow. Third, the 17-1\/2 in width: we check it at your home with a tape measure, not from plans.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this coil heat?\u003c\/strong\u003e Yes, with a heat pump; with a central air conditioner, it only cools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes a different furnace change everything?\u003c\/strong\u003e Not necessarily: we can build an insulated transition on site.\u003c\/p\u003e\n\n\u003ch3\u003eFinancial assistance\u003c\/h3\u003e\n\u003cp\u003eIncentives depend on the complete system. We check the match against Hydro-Québec's official list based on the installation date and summarize what applies to your file, before you sign.\u003c\/p\u003e\n\n\u003ch2\u003eA Trane 1.5 to 3 ton coil, installed by AirGreen\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free in-home estimate: furnace measurement, electrical service check, written quote for the complete Trane system. A \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing plan\u003c\/a\u003e is available to spread the cost.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Trane","offers":[{"title":"Default Title","offer_id":68402717786404,"sku":"5MXCB004AC3HCA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_TRANE_5MXC_5MXCB004AC3HCA_00_1_5_A_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766281","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-trane-5mxcb004ac3hca-a-1-5-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}