{"product_id":"serpentin-devaporateur-trane-5mxcc009ac3hca-a-3-a-5-tonnes","title":"TRANE 5MXCC009AC3HCA Evaporator A-Coil | 3 to 5 Tons","description":"\u003ch2\u003e5MXCC009AC3HCA: the 3 to 5 ton Trane coil for large homes with a 21 in furnace\u003c\/h2\u003e\n\u003cp\u003eHere is what to know first: the \u003cstrong\u003e5MXCC009AC3HCA\u003c\/strong\u003e is the one of the three 21 in coils in the Trane 5MXC series that covers the largest size. Its nominal size runs from 3 to 5 tons (60,000 BTU\/h), its cabinet measures 21 × 30 × 21 in and it weighs 82 lb net. It runs on \u003cstrong\u003eR-454B\u003c\/strong\u003e. It is equipment meant for large homes, multi-storey residences or those with a high cooling load.\u003c\/p\u003e\n\n\u003ch3\u003eQuestions our customers ask first\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it heat too?\u003c\/strong\u003e Yes, if the outdoor unit is a heat pump. With a central air conditioner, the coil only cools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan my current furnace stay?\u003c\/strong\u003e Yes. It keeps its blower and filters, and serves as backup heat when the outdoor temperature drops below the threshold we program with you.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep the existing outdoor unit?\u003c\/strong\u003e Generally not, because the coil must be matched with the unit specified by the manufacturer, with the same refrigerant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it eligible for incentives?\u003c\/strong\u003e That depends on the matched system and the installation date, not on the coil alone.\u003c\/p\u003e\n\n\u003ch3\u003eA high load: what are we talking about?\u003c\/h3\u003e\n\u003cp\u003eA Laval home with a big living room under a cathedral ceiling, a finished basement and several bedrooms upstairs does not cool like a bungalow. There is more air volume, more glazing, more appliances giving off heat. In those cases, a capacity of 3 to 5 tons is often needed. The load calculation, done at your home, settles it: we never pick the largest capacity by reflex.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the height and weight mean\u003c\/h3\u003e\n\u003cp\u003eA cabinet 30 in tall means space to plan for above the furnace. And 82 lb is not a package you carry at arm's length: the unit has to be handled carefully, especially on a narrow staircase. We plan the equipment and the crew accordingly. Because the model is multipoise (upflow, downflow, horizontal left or right), we can choose the orientation that fits best in your mechanical room.\u003c\/p\u003e\n\n\u003ch3\u003eThe same 21 in cabinet, two other sizes\u003c\/h3\u003e\n\u003cp\u003eAt the same width, you can compare:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe 5MXCC005AC3HCA: 1.5 to 3 tons;\u003c\/li\u003e\n\u003cli\u003ethe 5MXCC007AC3HCA: 1.5 to 3.5 tons;\u003c\/li\u003e\n\u003cli\u003ethe 5MXCC009AC3HCA: 3 to 5 tons, this one.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 5MXCD008AC3HCA (3 to 3.5 tons) and 5MXCD010AC3HCA (3 to 5 tons) models are 24-1\/2 in wide. If your furnace is that width, they avoid a transition. The first three models in the series, at 14-1\/2 in and 17-1\/2 in, do not go beyond 3.5 tons: they are therefore not suited to a home that requires 5 tons.\u003c\/p\u003e\n\n\u003ch3\u003eWhy the widest capacity range\u003c\/h3\u003e\n\u003cp\u003eThe 3 to 5 ton range is wide because it describes the range of outdoor units this coil can be matched with. At the quoting stage, we choose the exact capacity of the outdoor unit; we then confirm its AHRI number in the directory. The manufacturer's documents mention coils AHRI certified with Trane, American Standard, RunTru and Ameristar units (COR-PSD013B-EN), and no ENERGY STAR match published under the 5MXC prefix.\u003c\/p\u003e\n\n\u003ch3\u003eEquipment details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: 5MXCC009AC3HCA, 5MXC series;\u003c\/li\u003e\n\u003cli\u003etype: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003enominal size: 3 to 5 tons (60,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003eexpansion device: TXV;\u003c\/li\u003e\n\u003cli\u003eliquid connection: 3\/8 in; suction connection: 3\/4 or 7\/8 in;\u003c\/li\u003e\n\u003cli\u003econdensate drain: 3\/4 in NPT;\u003c\/li\u003e\n\u003cli\u003edimensions: 21 × 30 × 21 in; net weight: 82 lb;\u003c\/li\u003e\n\u003cli\u003erefrigerant sensor: location noted on the dimensional drawing (COR-PSD013B-EN, \"R454B Refrigerant Mitigation Sensor\", MCB kit); function not described in the document.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe coil in the circuit\u003c\/h3\u003e\n\u003cp\u003eThe refrigerant, cooled by the outdoor unit, enters the coil through the liquid connection, passes through the TXV and evaporates in the tubes, absorbing heat from the home's air. It then returns outdoors through the larger suction line. The water removed from the air falls into the pan and leaves through the drain. When the house is large, the volume of condensed water is significant: a clear drain is therefore essential.\u003c\/p\u003e\n\n\u003ch3\u003eA system this size, day to day\u003c\/h3\u003e\n\u003cp\u003eIn a large home, the first thing you notice is the relative quiet: a single outdoor unit, registers spread through every room, no window air conditioner humming in the bedroom. Then come the temperature differences between floors, often more pronounced than in a small house. A well-balanced duct system softens them. If it is not, it is better to know before the installation; we inspect the duct branches, registers and returns during the visit, and we say so frankly when a correction is needed.\u003c\/p\u003e\n\u003ch3\u003eBackup heating: how far to go?\u003c\/h3\u003e\n\u003cp\u003eThe temperature threshold at which the furnace takes over is specific to each home. A large, well-insulated home can let the heat pump work longer; an older home with significant heat loss will call on the furnace sooner. This is set at commissioning and can be adjusted after a few weeks of use, once you know how the house responds.\u003c\/p\u003e\n\n\u003ch3\u003eEfficiency: what can and cannot be said\u003c\/h3\u003e\n\u003cp\u003eThis coil has no efficiency rating of its own. The ratings belong to the certified system, that is, the coil plus outdoor unit pair. Be wary of quotes that state a rating without giving the AHRI number: that number is what lets you verify it, and it matters for assistance programs.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation at your home\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003evisit, furnace measurement, blower and electrical panel check;\u003c\/li\u003e\n\u003cli\u003esetting the coil in the plenum, with an insulated transition built on site if the width differs;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit, brazed piping, nitrogen leak test, vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment, an explanation of how it works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, and its refrigeration, ventilation and electrical work falls under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\n\u003ch3\u003eBefore ordering: the checks that count\u003c\/h3\u003e\n\u003cp\u003eThe refrigerant, first: R-454B on both sides. The blower, next: the larger the capacity, the larger the airflow required, and it must be able to deliver it. The electrical panel, finally: a high-capacity outdoor unit needs a suitable supply, which we check during the visit.\u003c\/p\u003e\n\n\u003ch3\u003eThe right reflex when in doubt\u003c\/h3\u003e\n\u003cp\u003eIf you are hesitating between this model and a smaller size, ask us for the load calculation in writing. It lets you compare quotes on identical bases and avoid both the unit that is too modest and the unit that is needlessly large.\u003c\/p\u003e\n\n\u003ch3\u003eFinancial assistance\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec's programs apply to the complete system. We check the official list against the installation date and honestly tell you what is possible.\u003c\/p\u003e\n\n\u003ch2\u003eA Trane 3 to 5 ton coil, installed by AirGreen\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we measure the furnace, check the electrical service and give you a written quote for the complete system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e helps you spread the cost.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Trane","offers":[{"title":"Default Title","offer_id":68402707923236,"sku":"5MXCC009AC3HCA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_TRANE_5MXC_5MXCC009AC3HCA_00_3_A_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766274","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-trane-5mxcc009ac3hca-a-3-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}