{"product_id":"serpentin-devaporateur-trane-5txcb004as3hca-a-2-a-3-5-tonnes","title":"TRANE 5TXCB004AS3HCA Evaporator A-Coil | 2 to 3.5 Tons","description":"\u003ch2\u003e5TXCB004AS3HCA: the 2 to 3.5 ton coil whose match is documented, with its AHRI numbers\u003c\/h2\u003e\n\u003cp\u003eSome coils are sold on the strength of a tonnage. This one rests on certification numbers that you can check yourself. The \u003cstrong\u003e5TXCB004AS3HCA\u003c\/strong\u003e, from the Trane 5TXC range, covers 2 to 3.5 tons (42,000 BTU\/h nominal), measures 17-1\/2 in wide and is matched with the Trane 5TWR7036A1 or 5TWX7036A1 outdoor unit. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\u003ch3\u003eLearning to read an AHRI number\u003c\/h3\u003e\n\u003cp\u003eAn AHRI number identifies a specific combination: this coil, this outdoor unit, this furnace or this air handler. It is the system's identity card. The published efficiency ratings and capacities are tied to that number, not to an individual part.\u003c\/p\u003e\n\u003cp\u003eWhy does this concern you? Because two quotes can show the same capacity and rest on different matches. Ask for the number, then look it up in the AHRI directory. We do it with you, before ordering.\u003c\/p\u003e\n\u003ch3\u003eThe two systems published for this coil\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFirst system.\u003c\/strong\u003e With the \u003cstrong\u003e5TWR7036A1\u003c\/strong\u003e heat pump, the AHRI number is 216763806. Cooling is published at 31,800 BTU\/h, and heating at 32,600 BTU\/h at 47 °F. The ratings are SEER2 15.2 and HSPF2 8.5.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecond system.\u003c\/strong\u003e With the \u003cstrong\u003e5TWX7036A1\u003c\/strong\u003e heat pump, the number is 216764349. Cooling reaches 32,200 BTU\/h, heating 32,800 BTU\/h at 47 °F, with SEER2 15.5 and HSPF2 8.5.\u003c\/p\u003e\n\u003cp\u003eThe gap is slim, and it comes from the outdoor unit model, not from the coil. We help you choose according to the house, the outdoor noise and the available location.\u003c\/p\u003e\n\u003ch3\u003eAnd ENERGY STAR, in all this?\u003c\/h3\u003e\n\u003cp\u003eTrane gives this combination as an ENERGY STAR certified example: the 5TXCB004 with the 5TWR7036A1 or 5TWX7036A1 heat pump, from the 17 Multi-Speed series, two-stage compressor, R-454B, certified for cold climates, SEER2 15.2 to 15.5 and HSPF2 8.5. The manufacturer also states that these coils are AHRI-certified with various split-system air conditioners and heat pumps (www.ahrinet.org, Trane COR-PSD003A-EN).\u003c\/p\u003e\n\u003ch3\u003eThe measurements to know\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal size: 2 to 3.5 tons, or 42,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 17-1\/2 × 22-1\/2 × 21-1\/2 in.\u003c\/li\u003e\n\u003cli\u003eNet weight: 50 lb.\u003c\/li\u003e\n\u003cli\u003e3\/8 in liquid connection, 7\/8 in suction.\u003c\/li\u003e\n\u003cli\u003e3\/4 in NPT condensate drain.\u003c\/li\u003e\n\u003cli\u003eTXV metering device, R-454B refrigerant.\u003c\/li\u003e\n\u003cli\u003ePosition: upflow, downflow, horizontal left or right.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote that the suction line goes up to 7\/8 in here, while the two smallest models in the series stay at 3\/4 in. The copper lines of the match are sized accordingly.\u003c\/p\u003e\n\u003ch3\u003eThis model and its 17-1\/2 in neighbours\u003c\/h3\u003e\n\u003cp\u003eThree coils share this width, and they differ by capacity:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e5TXCB003AS3HCA\u003c\/strong\u003e, 1.5 to 3 tons: a lower cabinet and a more modest starting size, with no specific outdoor unit named on the data sheet.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5TXCB004AS3HCA\u003c\/strong\u003e, this one: 2 to 3.5 tons, with two certified matches.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5TXCB006AS3HCA\u003c\/strong\u003e: 2 to 5 tons, for the house that asks for more, with three published matches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAmong the 21 in models, the 5TXCC005AS3HCA offers 2 to 4 tons. If your furnace is wider, that is an avenue to look at.\u003c\/p\u003e\n\u003ch3\u003eFor which home?\u003c\/h3\u003e\n\u003cp\u003eThe 2 to 3.5 ton range corresponds to a mid-sized house: a two-storey cottage, an extended bungalow, a deep semi-detached with a finished basement. It is neither the smallest nor the largest unit in the series, and that is precisely its strength. It leaves some margin if the house has been insulated or a room is added, without imposing an oversized unit.\u003c\/p\u003e\n\u003cp\u003eAn overly generous size causes short cycles: the air cools quickly, the machine stops before it has removed the moisture, and the house stays clammy. We calculate the home's load before setting the size, and we tell you honestly if it is better to aim for another model in the series.\u003c\/p\u003e\n\u003ch3\u003eWhy the 7\/8 in suction line matters\u003c\/h3\u003e\n\u003cp\u003eThe suction line carries the refrigerant back to the compressor of the outdoor unit. Its diameter must match the coil and the unit outside. We do not leave this to chance: during installation, we connect the right piping, braze it with care, then pressurize it with nitrogen to check for leaks before pulling a vacuum.\u003c\/p\u003e\n\u003cp\u003eIf the existing line set is not the right diameter, it is replaced. It is a technical detail that avoids a lot of trouble later.\u003c\/p\u003e\n\u003ch3\u003eWhat the heat pump changes on the bill\u003c\/h3\u003e\n\u003cp\u003eAn electric furnace turns each kilowatt-hour into an equal amount of heat. A heat pump moves outdoor heat to the inside: in mild weather, it supplies two to three times more than the electricity consumed. The colder it gets, the lower that efficiency falls, and the furnace takes over at the lowest temperatures. In summer, a single system cools every room and replaces the window units.\u003c\/p\u003e\n\u003ch3\u003eThe coil at work\u003c\/h3\u003e\n\u003cp\u003eIn the furnace plenum, the coil serves as the exchange surface. In summer, the refrigerant evaporates in it and removes heat and moisture from the air. In winter, with a heat pump, it gives up to that air the heat captured outdoors. The furnace keeps its blower and its filters, and takes over below the temperature threshold that we set together.\u003c\/p\u003e\n\u003ch3\u003eInstallation and commissioning\u003c\/h3\u003e\n\u003cp\u003eAirGreen, a family-run heating and cooling company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01. For this system, the visit and installation cover:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the cabinet in the plenum, with an insulated transition if the width differs, and sealing the connections;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit, brazing, the nitrogen leak test and the vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003eadjusting the airflow and handing over the explanations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSimple maintenance for many years\u003c\/h3\u003e\n\u003cp\u003eAfter commissioning, maintenance comes down to very little: a clean filter, a condensate drain that runs freely and an outdoor unit kept clear of snow, leaves and branches. We show you each point when we hand over the system, and we remain available if a doubt arises during the season.\u003c\/p\u003e\n\u003ch3\u003eQuestions to ask before signing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhich AHRI number appears on the quote?\u003c\/li\u003e\n\u003cli\u003eIs the furnace really 17-1\/2 in wide, or is a transition planned?\u003c\/li\u003e\n\u003cli\u003eDoes the blower deliver the system's airflow?\u003c\/li\u003e\n\u003cli\u003eIs the outdoor unit on the same refrigerant, R-454B?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eComparing two quotes\u003c\/h3\u003e\n\u003cp\u003eSet them side by side and look for the same items: the AHRI number, the outdoor unit, the SEER2 and HSPF2 ratings, the detail of the electrical and piping work. A quote that specifies all of that compares well; a vague quote cannot be compared.\u003c\/p\u003e\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe systems matched with this coil appear on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation. We check it on the official list at the time of the quote and we prepare the application with you.\u003c\/p\u003e\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Trane system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Trane","offers":[{"title":"Default Title","offer_id":68402709102884,"sku":"5TXCB004AS3HCA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_TRANE_5TXC_5TXCB004AS3HCA_00_2_A_3_5_TONNES_42000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766280","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-trane-5txcb004as3hca-a-2-a-3-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}