{"product_id":"serpentin-devaporateur-trane-5txcb006as3hca-a-2-a-5-tonnes","title":"TRANE 5TXCB006AS3HCA Evaporator A-Coil | 2 to 5 Tons","description":"\u003ch2\u003eTrane 5TXCB006AS3HCA: a 2 to 5 ton coil, a slim 17-1\/2 in wide and 26-3\/4 in high\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e5TXCB006AS3HCA\u003c\/strong\u003e is the coil with the widest nominal range in the Trane 5TXC series: 2 to 5 tons, or 60,000 BTU\/h. Its shape is that of a column, 17-1\/2 in wide by 26-3\/4 in high, and it is matched with three published outdoor units. It is meant for homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore who have a furnace of average width and a house with some scale.\u003c\/p\u003e\n\u003ch3\u003eWhy a range of 2 to 5 tons?\u003c\/h3\u003e\n\u003cp\u003eThis span does not mean the coil suits everything. It indicates that the same exchanger is matched with outdoor units of different capacities. It is the complete system, not the coil, that determines the real cooling and heating output.\u003c\/p\u003e\n\u003cp\u003eA telling example: among the published matches, cooling varies from 22,000 BTU\/h to 33,400 BTU\/h. The number of tons printed on the coil is therefore only a reference point. Only the system's AHRI number tells you what you will get.\u003c\/p\u003e\n\u003ch3\u003eThree matches, three personalities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWith the 5TWR7036A1\u003c\/strong\u003e (AHRI 216763871): cooling of 33,200 BTU\/h, heating of 33,000 BTU\/h at 47 °F, SEER2 16.0 and HSPF2 8.7.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWith the 5TWX7036A1\u003c\/strong\u003e (AHRI 216764367): 33,400 BTU\/h in cooling, 33,200 BTU\/h in heating at 47 °F, the same ratings, SEER2 16.0 and HSPF2 8.7.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWith the 5TWV8X24A1\u003c\/strong\u003e (AHRI 217179561): 22,000 BTU\/h in cooling, 23,000 BTU\/h in heating at 47 °F, SEER2 18.1 and HSPF2 8.5.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe third choice has the most modest capacity and the highest SEER2. It suits a house with a reduced load, for example one that is well insulated. The first two deliver more heat and more cooling. We guide you according to the calculated load, not according to the price of the unit.\u003c\/p\u003e\n\u003ch3\u003eReading the numbers without being fooled\u003c\/h3\u003e\n\u003cp\u003eHeating is published at 47 °F: that is the reference outdoor temperature for the calculation. In deep cold, a heat pump's capacity drops, which is why the furnace stays on as backup. SEER2 describes cooling efficiency over the season, HSPF2 that of heating. These two ratings belong to the certified system, never to the coil alone.\u003c\/p\u003e\n\u003cp\u003eIf a quote cites a SEER2 without an AHRI number, ask the question. A figure without a number cannot be verified.\u003c\/p\u003e\n\u003ch3\u003eDimensions and connections\u003c\/h3\u003e\n\u003cp\u003eDimensions W × H × D: 17-1\/2 × 26-3\/4 × 21-1\/2 in. Net weight of 55 lb. Liquid connection of 3\/8 in, suction connection of 7\/8 in, condensate drain of 3\/4 in NPT. TXV metering device, R-454B refrigerant. The manufacturer states that the coil is multi-position: upflow, downflow, horizontal left or right.\u003c\/p\u003e\n\u003cp\u003eThe height of 26-3\/4 in means you must check the space above the furnace. In a low mechanical room, another model may be more suitable.\u003c\/p\u003e\n\u003ch3\u003eWho are its closest neighbours?\u003c\/h3\u003e\n\u003cp\u003eAt the same width, there are three models: the \u003cstrong\u003e5TXCB003AS3HCA\u003c\/strong\u003e, 1.5 to 3 tons, lower; the \u003cstrong\u003e5TXCB004AS3HCA\u003c\/strong\u003e, 2 to 3.5 tons, with two matches; and this one. The choice comes down to the volume of air to treat and the available height.\u003c\/p\u003e\n\u003cp\u003eIf your furnace is 21 in wide, the \u003cstrong\u003e5TXCC007AS3HCA\u003c\/strong\u003e offers a range of 3 to 5 tons at the same height of 26-3\/4 in. If it is 24-1\/2 in, look at the \u003cstrong\u003e5TXCD008AS3HCA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat is the coil for, exactly?\u003c\/h3\u003e\n\u003cp\u003eIt is the exchanger that cools or warms the house air. In summer, the cold refrigerant absorbs heat from the air passing through it, and the condensation flows out through the drain. In winter, with a heat pump, the coil returns to the air the heat captured outdoors. A single duct network serves both seasons.\u003c\/p\u003e\n\u003ch3\u003eShould you keep the furnace?\u003c\/h3\u003e\n\u003cp\u003eYes, and it is an advantage. It keeps its blower, its filters and its heating elements. It provides backup heating when the outdoor temperature falls below the threshold that we set with you. An electric furnace converts each kilowatt-hour into an equal amount of heat; a heat pump supplies two to three times more in mild weather.\u003c\/p\u003e\n\u003ch3\u003eThe case of a house with a finished basement\u003c\/h3\u003e\n\u003cp\u003eIn a South Shore cottage whose basement has been finished, the furnace is often in a small utility room with a drop ceiling. The cabinet height then becomes the first question. Sometimes part of the ceiling has to be modified or a duct moved. We would rather see this at the visit, before the order, than on installation day.\u003c\/p\u003e\n\u003cp\u003eIn an open-plan North Shore house, it is rather the air distribution that will hold our attention: a large common room needs well-placed vents so that the cool air reaches the far end.\u003c\/p\u003e\n\u003ch3\u003eWhat we check at your home\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ethe furnace width, and the insulated transition to build if it differs from 17-1\/2 in;\u003c\/li\u003e\n\u003cli\u003ethe free height for a 26-3\/4 in cabinet;\u003c\/li\u003e\n\u003cli\u003ethe blower, which must deliver the system's airflow;\u003c\/li\u003e\n\u003cli\u003ethe electrical panel, which must accommodate the outdoor unit's circuit;\u003c\/li\u003e\n\u003cli\u003ethe location outside, sheltered from snow sliding off the roof.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOur installation method\u003c\/h3\u003e\n\u003cp\u003eA family-run heating and cooling company based in Montreal for more than fifteen years, AirGreen carries out its work under RBQ licence 5645-9605-01. For a system like this one, we place the coil in the plenum, seal the duct joints, set the outdoor unit on a pad or bracket, braze the piping, pressure-test with nitrogen and pull a vacuum. We then connect the condensate drain and the thermostat, then we set the airflow and explain the whole system to you.\u003c\/p\u003e\n\u003ch3\u003eWhat Trane publishes about these coils\u003c\/h3\u003e\n\u003cp\u003eTrane states that these coils are AHRI-certified with various split-system air conditioners and heat pumps (see www.ahrinet.org, Trane document COR-PSD003A-EN). An ENERGY STAR certified example from the series pairs the 5TXCB004 with the 5TWR7036A1 or 5TWX7036A1 heat pump, on R-454B, certified for cold climates, SEER2 15.2 to 15.5 and HSPF2 8.5.\u003c\/p\u003e\n\u003ch3\u003eOne last planning tip\u003c\/h3\u003e\n\u003cp\u003eIf you are planning future work, such as attic insulation, new windows or an addition, tell us before the quote. The home's load changes, and with it the choice of match among the three published. Better to think about it now than to adjust later.\u003c\/p\u003e\n\u003ch3\u003eTo consider before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B refrigerant requires an outdoor unit with the same refrigerant.\u003c\/li\u003e\n\u003cli\u003eThe ratings apply to the complete certified system.\u003c\/li\u003e\n\u003cli\u003eThe AHRI number must appear on the quote.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe matched Trane system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation; we check it on the official list at the quote and we prepare the application with you.\u003c\/p\u003e\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Trane system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Trane","offers":[{"title":"Default Title","offer_id":68402711101732,"sku":"5TXCB006AS3HCA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_TRANE_5TXC_5TXCB006AS3HCA_00_2_A_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766281","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-trane-5txcb006as3hca-a-2-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}