{"product_id":"serpentin-devaporateur-trane-5txcc007as3hca-a-3-a-5-tonnes","title":"TRANE 5TXCC007AS3HCA Evaporator A-Coil | 3 to 5 Tons","description":"\u003ch2\u003e5TXCC007AS3HCA or its twin 5TXCC009AS3HCA? How to choose a 3 to 5 ton Trane coil in 21 in\u003c\/h2\u003e\n\u003cp\u003eTwo coils in the 5TXC series show exactly the same commercial data sheet: 3 to 5 tons, 60,000 BTU\/h, 21 in wide, R-454B, TXV and the 5TWR7036A1 outdoor unit at the top of the list. They are the \u003cstrong\u003e5TXCC007AS3HCA\u003c\/strong\u003e and the 5TXCC009AS3HCA. They differ by cabinet height and by weight. This page covers the first, the lower of the two, which we install in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\u003ch3\u003eWhat really separates them\u003c\/h3\u003e\n\u003cp\u003eThe 5TXCC007AS3HCA is 26-3\/4 in high and weighs 61 lb. Its twin is taller and heavier. Everything else matches: the 21 in width, the 21-1\/2 in depth, the 3\/8 in and 7\/8 in connections, the 3\/4 in NPT drain, the TXV metering device.\u003c\/p\u003e\n\u003cp\u003eThe practical conclusion: you take the model that fits in your plenum. If the clearance above the furnace is limited, it is the lower one. If there is room, the published matches of the taller one may include another outdoor unit, and we look at both options with you.\u003c\/p\u003e\n\u003ch3\u003eComparing with the rest of the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e5TXCC005AS3HCA\u003c\/strong\u003e: also 21 in, but only 2 to 4 tons, with a lower cabinet.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5TXCB006AS3HCA\u003c\/strong\u003e: 2 to 5 tons, at 17-1\/2 in, at the same height of 26-3\/4 in. Choose it for a narrower furnace.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5TXCD008AS3HCA\u003c\/strong\u003e: 3 to 5 tons and the same height, but 24-1\/2 in wide.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn other words, the 5TXCC007AS3HCA sits at the crossroads of three cases: the same height as the narrow column, the same width as the small 21 in, the same range as the large models.\u003c\/p\u003e\n\u003ch3\u003eThree published systems\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWith the 5TWR7036A1\u003c\/strong\u003e (AHRI 216763889): 33,200 BTU\/h in cooling and 33,000 BTU\/h in heating at 47 °F, with SEER2 16.0 and HSPF2 8.7.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWith the 5TWX7036A1\u003c\/strong\u003e (AHRI 216764396): 33,400 BTU\/h in cooling, 33,200 BTU\/h in heating at 47 °F, SEER2 16.0 and HSPF2 8.7.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWith the 5TWV8X48A1\u003c\/strong\u003e (AHRI 215865103): 45,500 BTU\/h in both modes at 47 °F, SEER2 18.1 and HSPF2 8.5.\u003c\/p\u003e\n\u003cp\u003eThe third stands out: it delivers more capacity and the highest SEER2 of the three. It is aimed at a house with a heavier load. The first two suit an average house. The load calculation settles it.\u003c\/p\u003e\n\u003ch3\u003eWhy a 3 to 5 ton coil with 33,200 BTU\/h of capacity?\u003c\/h3\u003e\n\u003cp\u003eThe question comes up often. The coil's tonnage designates the range in which it can work, not the capacity the system will deliver. The real capacity depends on the outdoor unit. A house that only needs 33,000 BTU\/h does not have to pay for a bigger unit, which is why we start from the load, not from the tonnage printed on the box.\u003c\/p\u003e\n\u003ch3\u003eThe coil in its environment\u003c\/h3\u003e\n\u003cp\u003eIt fits into the plenum of the furnace or of a blower cabinet. In cooling, the refrigerant evaporates in its tubes and picks up heat and moisture from the air; in heating mode with a heat pump, it returns the heat captured outdoors. The furnace keeps its blower and its filters, and serves as backup heat when the cold goes beyond the threshold that we set with you.\u003c\/p\u003e\n\u003ch3\u003eA big basement, a big blower\u003c\/h3\u003e\n\u003cp\u003eAt this size, air distribution becomes as important as the coil. An undersized blower or a choked main duct gives too little airflow: the coil frosts up more easily, and the rooms far away stay lukewarm. We measure the airflow during commissioning and we correct what can be corrected, whether it is the blower speed, a damper or a section of duct.\u003c\/p\u003e\n\u003cp\u003eIn a North Shore house with a large finished basement, these checks avoid surprises during the first heat wave.\u003c\/p\u003e\n\u003ch3\u003eBefore ordering, we check\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ethat the furnace is 21 in wide, otherwise we prepare an insulated transition;\u003c\/li\u003e\n\u003cli\u003ethat the space above the unit accepts a 26-3\/4 in cabinet;\u003c\/li\u003e\n\u003cli\u003ethat the blower reaches the system's airflow;\u003c\/li\u003e\n\u003cli\u003ethat the electrical panel can accommodate the outdoor unit's circuit, which matters at this size.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHow the job unfolds\u003c\/h3\u003e\n\u003cp\u003eAirGreen, a family-run heating and cooling company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01. The installation day goes like this: first the coil goes into the plenum and the joints are sealed; the outdoor unit is set on its support; the piping is brazed, the leak test is done with nitrogen and a vacuum is pulled; the drain and the thermostat are connected; and we finish with commissioning, airflow adjustment and a step-by-step explanation.\u003c\/p\u003e\n\u003ch3\u003eRatings and certifications: what Trane writes\u003c\/h3\u003e\n\u003cp\u003eAccording to Trane, these coils are AHRI-certified with various split-system air conditioners and heat pumps (www.ahrinet.org, Trane COR-PSD003A-EN). An ENERGY STAR certified example from the series brings together the 5TXCB004 and the 5TWR7036A1 or 5TWX7036A1 heat pump, on R-454B, certified for cold climates, SEER2 15.2 to 15.5 and HSPF2 8.5.\u003c\/p\u003e\n\u003ch3\u003eHeating: what changes compared with electric\u003c\/h3\u003e\n\u003cp\u003eAn electric furnace produces as much heat as the energy it consumes. A heat pump, in mild weather, supplies two to three times more. That gain shrinks with the cold, and the furnace takes over. For a large house heated with electricity, the calculation is worth doing.\u003c\/p\u003e\n\u003ch3\u003eKeeping a cool head about the numbers\u003c\/h3\u003e\n\u003cp\u003eBrochures like big numbers. Instead, hold on to three simple questions. What is my home's real load? Which system, identified by its AHRI number, covers it without excess? Can the furnace and the plenum receive this coil as it is? If the answers are clear, the rest sorts itself out without difficulty. If not, it is better to stop and rethink the project than to install a mismatched unit.\u003c\/p\u003e\n\u003ch3\u003eTo remember before choosing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B requires an outdoor unit with the same refrigerant.\u003c\/li\u003e\n\u003cli\u003eThe ratings belong to the certified system, not to the coil.\u003c\/li\u003e\n\u003cli\u003eAlways ask for the AHRI number in writing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAfter the installation\u003c\/h3\u003e\n\u003cp\u003eWe remain reachable after commissioning. If a noise surprises you or if one room stays warmer than the others, call us: a damper or blower adjustment is often enough. A system that is well adjusted in the first week performs better for years.\u003c\/p\u003e\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe matched Trane system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation; we check it on the official list at the quote and we prepare the application with you.\u003c\/p\u003e\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Trane system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Trane","offers":[{"title":"Default Title","offer_id":68402711822628,"sku":"5TXCC007AS3HCA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_TRANE_5TXC_5TXCC007AS3HCA_00_3_A_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766281","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-trane-5txcc007as3hca-a-3-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}