{"product_id":"serpentin-devaporateur-trane-5txcd008as3hca-a-3-a-5-tonnes","title":"TRANE 5TXCD008AS3HCA Evaporator A-Coil | 3 to 5 Tons","description":"\u003ch2\u003e5TXCD008AS3HCA: 24-1\/2 in wide, 3 to 5 tons, for the widest furnaces in the Trane 5TXC range\u003c\/h2\u003e\n\u003cp\u003eFurnaces in large homes often have a wide plenum, sometimes wider than what coils of common size accept. In the 5TXC range, the letter D designates the greatest width: 24-1\/2 in. The \u003cstrong\u003e5TXCD008AS3HCA\u003c\/strong\u003e is part of it. It covers 3 to 5 tons (60,000 BTU\/h), measures 26-3\/4 in high and weighs 64 lb. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\u003ch3\u003eIs this coil made for my furnace?\u003c\/h3\u003e\n\u003cp\u003eThe first answer lies in a tape measure. If your furnace plenum is 24-1\/2 in wide, the coil fits it directly. If it is narrower, we build an insulated transition on site; but for a furnace of 21 in or less, a narrower coil from the series will generally be a better match, and you avoid unnecessary sheet-metal pieces.\u003c\/p\u003e\n\u003ch3\u003eQuestions and answers about this model\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy the D rather than the C?\u003c\/strong\u003e Because the width follows the furnace. The 5TXCD008AS3HCA is the natural choice for a 24-1\/2 in plenum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it taller than the others?\u003c\/strong\u003e No. At 26-3\/4 in, it is less tall than its sibling 5TXCD010AS3HCA, which is also 24-1\/2 in. It therefore suits a room where height is at a premium.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich outdoor unit?\u003c\/strong\u003e Three matches are published, detailed below.\u003c\/p\u003e\n\u003ch3\u003eThe systems published for the 5TXCD008AS3HCA\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWith the \u003cstrong\u003e5TWR7036A1\u003c\/strong\u003e (AHRI 216763913): cooling of 33,400 BTU\/h, heating of 33,200 BTU\/h at 47 °F, SEER2 16.0 and HSPF2 8.7.\u003c\/li\u003e\n\u003cli\u003eWith the \u003cstrong\u003e5TWR7048A1\u003c\/strong\u003e (AHRI 218334933): cooling of 43,500 BTU\/h, heating of 46,000 BTU\/h at 47 °F, SEER2 16.0 and HSPF2 8.5.\u003c\/li\u003e\n\u003cli\u003eWith the \u003cstrong\u003e5TWX7036A1\u003c\/strong\u003e (AHRI 216764416): cooling of 33,600 BTU\/h, heating of 33,400 BTU\/h at 47 °F, SEER2 16.0 and HSPF2 8.7.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 5TWR7048A1 is the one that brings the most capacity, notably in heating. The two 7036 units are closer to each other. For a large house, heating capacity at 47 °F is an important criterion, but it is not the only one: the level of insulation, the windows and the number of floors count just as much.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cp\u003eCased coil, 5TXC range. Dimensions W × H × D: 24-1\/2 × 26-3\/4 × 21-1\/2 in. Net weight of 64 lb. Nominal size of 60,000 BTU\/h. Liquid connection of 3\/8 in, suction of 7\/8 in, condensate drain of 3\/4 in NPT. TXV metering device and R-454B refrigerant. The manufacturer states that it is multi-position: upflow, downflow, horizontal left or right.\u003c\/p\u003e\n\u003ch3\u003eWhere it sits in the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSame 3 to 5 ton range in 21 in: the \u003cstrong\u003e5TXCC007AS3HCA\u003c\/strong\u003e and \u003cstrong\u003e5TXCC009AS3HCA\u003c\/strong\u003e, if the furnace is narrower.\u003c\/li\u003e\n\u003cli\u003eSame width, more height: the \u003cstrong\u003e5TXCD010AS3HCA\u003c\/strong\u003e, which is matched with the 5TWV0X48A1 unit.\u003c\/li\u003e\n\u003cli\u003eDifferent range: the \u003cstrong\u003e5TXCB006AS3HCA\u003c\/strong\u003e, 2 to 5 tons, at 17-1\/2 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBetween the two 24-1\/2 in models, the available height and the desired outdoor unit make the difference: the 5TXCD008AS3HCA stays in the family of 7036 and 7048 units, while its sibling turns toward the 5TWV line.\u003c\/p\u003e\n\u003ch3\u003eThe coil's role in the heat pump\u003c\/h3\u003e\n\u003cp\u003eInstalled in the plenum, it makes the refrigerant work in contact with the circulating air. In summer, it removes heat and moisture. In winter, with a heat pump, it gives up to the air the heat captured outdoors. The furnace keeps its blower and remains the backup heat below the temperature threshold set with you.\u003c\/p\u003e\n\u003ch3\u003eLarge homes have specific needs\u003c\/h3\u003e\n\u003cp\u003eIn a large house, you think first of capacity, but it is often the electricity and the air distribution that decide. A properly sized outdoor unit calls for a circuit dedicated to it. A large duct network calls for a blower capable of overcoming its resistance. We assess both. It can happen that two smaller systems serve a very large house better, and we will tell you frankly.\u003c\/p\u003e\n\u003ch3\u003eOne house, three seasons\u003c\/h3\u003e\n\u003cp\u003eIn spring and fall, when temperatures stay mild, the heat pump handles the heating alone, and that is the period when the saving compared with pure electricity is felt most. An electric furnace converts each kilowatt-hour into an equal amount of heat; the heat pump, for its part, moves heat and delivers two to three times more in mild weather. When the cold sets in, that ratio shrinks and the furnace takes the main role again.\u003c\/p\u003e\n\u003cp\u003eIn summer, the same coil cools the floors and removes humidity. In a large house, the difference between a well-sized system and an oversized one is noticed right away: the first maintains an even coolness, the second leaves the air cold but sticky.\u003c\/p\u003e\n\u003ch3\u003eA visit that takes its time\u003c\/h3\u003e\n\u003cp\u003eFor a large house on the South Shore or in Laval, the visit lasts longer than you might imagine. We go through every floor, we locate the main ducts, we look at where the air return is installed, we open the panel. We also note the possible location of the outdoor unit and its exposure to wind and snow. At the end, you receive a written quote, with the AHRI number of the proposed system.\u003c\/p\u003e\n\u003ch3\u003eTrane writes this\u003c\/h3\u003e\n\u003cp\u003eThese coils are AHRI-certified with various split-system air conditioners and heat pumps (see www.ahrinet.org, Trane document COR-PSD003A-EN). ENERGY STAR certified example from the series: the 5TXCB004 with a 5TWR7036A1 or 5TWX7036A1 heat pump, on R-454B, certified for cold climates, SEER2 15.2 to 15.5 and HSPF2 8.5.\u003c\/p\u003e\n\u003ch3\u003eOur installation in five steps\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMeasure the furnace, the blower and the electrical panel.\u003c\/li\u003e\n\u003cli\u003eSet the coil in the plenum and seal the duct joints.\u003c\/li\u003e\n\u003cli\u003eInstall the outdoor unit, braze the piping, pressure-test with nitrogen and pull a vacuum.\u003c\/li\u003e\n\u003cli\u003eConnect the condensate drain and the thermostat.\u003c\/li\u003e\n\u003cli\u003eCommission the system, set the airflow and explain everything to you.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eAirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, and its work is done under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\u003ch3\u003eTo consider before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B requires an outdoor unit with the same refrigerant.\u003c\/li\u003e\n\u003cli\u003ePublished ratings belong to the certified system.\u003c\/li\u003e\n\u003cli\u003eThe 24-1\/2 in width must match the furnace.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the system's airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOne last check\u003c\/h3\u003e\n\u003cp\u003eBefore the order, we go over the quote together: the coil model, the chosen outdoor unit, the AHRI number, the possible transition and the electrical work. Nothing should surprise you on installation day, and every line should be explainable in one sentence.\u003c\/p\u003e\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe matched Trane system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation; we check it on the official list at the time of the quote and we prepare the application with you.\u003c\/p\u003e\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Trane system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Trane","offers":[{"title":"Default Title","offer_id":68402714247460,"sku":"5TXCD008AS3HCA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_TRANE_5TXC_5TXCD008AS3HCA_00_3_A_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795766281","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-trane-5txcd008as3hca-a-3-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}