{"product_id":"serpentin-devaporateur-york-ctf24a5abs1-a-2-tonnes","title":"YORK CTF24A5ABS1 Evaporator A-Coil | 2 Tons","description":"\u003ch2\u003eYork CTF24A5ABS1: the narrow 14-1\/2 in cased coil for a small furnace\u003c\/h2\u003e\n\u003cp\u003eWhen the furnace sits in a condo closet, in the basement of a plex or in the laundry room of a bungalow, every inch counts. York’s \u003cstrong\u003eCTF24A5ABS1\u003c\/strong\u003e is the narrower of the two 2-ton coils in the CTF series that we offer: 14-1\/2 in wide, in an insulated cabinet that sits directly on top of the furnace. It runs on \u003cstrong\u003eR-454B\u003c\/strong\u003e and can both cool and heat, depending on the outdoor unit it is paired with.\u003c\/p\u003e\n\u003cp\u003eAirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhat this coil does, in a few words\u003c\/h3\u003e\n\u003cp\u003eAn evaporator coil is the heat exchanger placed in the furnace’s airstream. Refrigerant arrives from the outdoor unit, evaporates inside it and absorbs heat from the air passing through. The result is that the air coming out of the vents is cooler and drier.\u003c\/p\u003e\n\u003cp\u003eWith a heat pump, the circuit can also run in reverse in winter. With a plain central air conditioner, it only does the cooling. It is the same part, but not the same use.\u003c\/p\u003e\n\n\u003ch3\u003eWhy 14-1\/2 in changes the technical visit\u003c\/h3\u003e\n\u003cp\u003eA cabinet has to fit the top of the furnace. If it is wider, it overhangs; if it is narrower, air goes around the coil and some of the heat is never exchanged. Here, the 14-1\/2 in width matches small furnaces, the kind found in townhouses and compact apartments.\u003c\/p\u003e\n\u003cp\u003eSo we measure the furnace before ordering. If the gap is small, we build an insulated transition on site. The cabinet measures 14-1\/2 × 21-5\/8 in and weighs 33 lb, which is still easy to handle in a tight space.\u003c\/p\u003e\n\n\u003ch3\u003eWhat you have at home before and after\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBefore: an electric furnace or an old central air conditioner, sometimes only window units.\u003c\/li\u003e\n\u003cli\u003eAfter: a matched York outdoor unit, a coil in the plenum, and the same air ductwork as before.\u003c\/li\u003e\n\u003cli\u003eThe existing blower, filters and ducts are kept.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThere is nothing to drill through the walls to distribute the air: it all already travels through the home’s ducts. That is the main argument for an installation on an existing furnace.\u003c\/p\u003e\n\n\u003ch3\u003eA word on the A shape\u003c\/h3\u003e\n\u003cp\u003eThe coil is an A-coil: two sloped faces that meet at the top. Air rises through the centre and passes through both faces. The positions published by the manufacturer are upflow or downflow, which gives some flexibility depending on the direction your furnace moves air.\u003c\/p\u003e\n\u003cp\u003eThe metering device is a TXV. It doses the refrigerant sent into the coil according to the actual load, instead of letting a fixed flow through.\u003c\/p\u003e\n\n\u003ch3\u003eCTF24A5ABS1 spec sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e York CTF, cased coil\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNominal size:\u003c\/strong\u003e 2 tons, or 24,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R-454B\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 14-1\/2 × 21-5\/8 in (W × H)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNet weight:\u003c\/strong\u003e 33 lb\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e 3\/8 in for the liquid line, 3\/4 in for the suction line\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNominal airflow:\u003c\/strong\u003e 800 CFM\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10-year limited parts warranty, as stated in the York brochure PUBL-8373-B-0324\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLeak detection: the A2L sensor\u003c\/h3\u003e\n\u003cp\u003eR-454B is an A2L refrigerant, and the coil ships with what is needed to monitor it. A factory-installed sensor (code S) is fixed to the coil plate and connected to the RDS control board.\u003c\/p\u003e\n\u003cp\u003eIf the concentration exceeds 15% of the LFL, the call to the compressor is cut and the indoor fan starts. York manual 6356510-UIM-C-0824 describes how this works. The CTF, CTM and CTU coils for R-454B include this sensor.\u003c\/p\u003e\n\n\u003ch3\u003eCTF24A5ABS1 or CTF24B5ABS1: how to choose\u003c\/h3\u003e\n\u003cp\u003eBoth models have the same 2-ton size, the same refrigerant, the same TXV and the same warranty. The difference comes down to the size of the cabinet.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCTF24A5ABS1 (this page):\u003c\/strong\u003e 14-1\/2 in wide.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTF24B5ABS1:\u003c\/strong\u003e 17-1\/2 in wide, for wider furnaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe right choice is the one that matches the width of your furnace. Choosing at random means building a larger transition. Our technician takes the measurement and makes the call on site.\u003c\/p\u003e\n\n\u003ch3\u003ePairing with the outdoor unit\u003c\/h3\u003e\n\u003cp\u003eTechnically speaking, the coil is not sold on its own: it forms a system with a York outdoor unit of the same capacity and the same refrigerant. Before ordering, we confirm the exact pairing and its AHRI number, so that the ratings we quote are the ones you will actually get.\u003c\/p\u003e\n\u003cp\u003eAmong other things, York publishes these reference points:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe YORK HH8 heat pump (LX series) on R-454B, with a variable-speed compressor, ENERGY STAR certified for Canada and the United States;\u003c\/li\u003e\n\u003cli\u003ecertified pairings with HH824E2S11, HH836E2S11, HH860E2S11 and HH860E2S12, depending on the coil;\u003c\/li\u003e\n\u003cli\u003eairflow of about 350 to 450 CFM per ton of outdoor unit, with an external static pressure of 0.2 to 0.6 in w.c.;\u003c\/li\u003e\n\u003cli\u003ea 3\/8 in liquid line, with larger lines possibly required for long distances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe coil has no efficiency rating on its own. The SEER2, EER2 and HSPF2 ratings belong to the matched system. The AHRI number is what lets you compare two quotes honestly.\u003c\/p\u003e\n\n\u003ch3\u003eHeat pump and furnace: who does what\u003c\/h3\u003e\n\u003cp\u003eIn an add-on installation, the heat pump handles most of the heating season. The furnace stays on as backup and takes over when the outdoor temperature drops below the threshold that we set with you.\u003c\/p\u003e\n\u003cp\u003eAn electric furnace turns every kilowatt-hour into an equal amount of heat. A heat pump moves heat and delivers two to three times more than the electricity it uses in mild temperatures. The colder it gets, the lower that efficiency falls, which is why it makes sense to keep the furnace.\u003c\/p\u003e\n\n\u003ch3\u003eThe right size for a small space\u003c\/h3\u003e\n\u003cp\u003eAn oversized system runs in short cycles. It cools quickly but does not have time to dry the air, and the house stays damp in July. The 2-ton size suits townhouses, compact bungalows and plex units that have their own furnace.\u003c\/p\u003e\n\u003cp\u003eWe confirm the home’s load before proposing this size. If the calculation points to a different one, we tell you.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to check before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B requires an outdoor unit that uses the same refrigerant, installed at the same time. Keeping your old air conditioner is generally not possible.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the system’s airflow.\u003c\/li\u003e\n\u003cli\u003eThe width of the furnace must be confirmed on site.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified pairing, not to the coil alone.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHydro-Québec incentives\u003c\/h3\u003e\n\u003cp\u003eEligibility depends on the complete system, never on the coil alone. We check Hydro-Québec’s official list according to the installation date and tell you what applies to your project.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan it heat?\u003c\/strong\u003e Yes, when it is paired with a heat pump. With a central air conditioner, it only does the cooling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still useful?\u003c\/strong\u003e Yes, as backup heating for the coldest days.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation by AirGreen in Greater Montreal\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, operating under RBQ licence 5645-9605-01. For this coil and its outdoor unit, we take care of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace and checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003emounting the coil in the plenum, with a transition built on site if needed, and sealing the connections;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit on a pad or bracket, the brazed piping, the nitrogen pressure test and the evacuation;\u003c\/li\u003e\n\u003cli\u003ethe condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and an explanation of how the system works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate\u003c\/strong\u003e: we measure the furnace, check the electrical service and give you a written quote for the complete York system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":68402461868324,"sku":"CTF24A5ABS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_YORK_CTF_CTF24A5ABS1_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765557","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-york-ctf24a5abs1-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}