{"product_id":"serpentin-devaporateur-york-ctf42c5ces1-a-3-5-tonnes","title":"YORK CTF42C5CES1 Evaporator A-Coil | 3.5 Tons","description":"\u003ch2\u003eCTF42C5CES1: the 3.5-ton York coil, the most compact of the group at 21 in wide\u003c\/h2\u003e\n\u003cp\u003eOf the four York CTF coils we compare here, this is the only one rated at 3.5 tons. The other three step up to 4 tons. If your home sits comfortably on one or two floors, without a large open-plan space, this is often the right starting point for a conversation about a central heat pump.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eCTF42C5CES1\u003c\/strong\u003e is an A-shaped evaporator coil, supplied cased, that runs on \u003cstrong\u003eR-454B\u003c\/strong\u003e refrigerant. We install it for customers in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhat an evaporator coil does, in plain terms\u003c\/h3\u003e\n\u003cp\u003ePicture the cold glass of an iced water in summer: warm room air cools against it and leaves water on the glass. The coil does the same thing on a much larger scale, inside the plenum of your furnace. Refrigerant arrives from the outdoor unit, evaporates in the tubes and absorbs heat from the air moved by the blower. The cooled air goes back out through the ducts; the moisture condenses and runs off to the drain.\u003c\/p\u003e\n\u003cp\u003eWith a heat pump outside, the cycle can be reversed. In winter, the refrigerant then carries heat into the house, and the furnace stays in reserve for the coldest days.\u003c\/p\u003e\n\n\u003ch3\u003eWhere it fits: 3.5 tons, or 42,000 BTU\/h nominal\u003c\/h3\u003e\n\u003cp\u003eThe 42,000 BTU\/h figure is a nominal size, a capacity label used to match the coil with the outdoor unit. On its own, it does not tell you whether the house will be comfortable. What counts is the real heat loss of the building envelope, the quality of the ductwork and the blower’s ability to move the air required. That is why we visit your home first, tape measure in hand, before suggesting a size.\u003c\/p\u003e\n\u003cp\u003eA coil that is too big for a compact house does not bring more comfort. It tends to run in short cycles and leave the air more humid. A 3.5-ton size therefore suits mid-sized homes whose ducts do not serve a long string of rooms.\u003c\/p\u003e\n\n\u003ch3\u003eA spec sheet you can read in a minute\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ecased, A-coil from the CTF range;\u003c\/li\u003e\n\u003cli\u003e21 in wide, 25 in high, net weight of 52 lb;\u003c\/li\u003e\n\u003cli\u003e3\/8 in liquid line connection and 7\/8 in suction line connection;\u003c\/li\u003e\n\u003cli\u003eTXV metering;\u003c\/li\u003e\n\u003cli\u003enominal airflow of 1,400 CFM;\u003c\/li\u003e\n\u003cli\u003eupflow or downflow installation, depending on the furnace;\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty from the manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 25 in height is the lowest of the four models. The CTF42C5CES1 therefore slips more easily into a mechanical room where the clearance above the furnace is tight, which we measure before confirming anything.\u003c\/p\u003e\n\n\u003ch3\u003eBuilt-in safety for R-454B\u003c\/h3\u003e\n\u003cp\u003eR-454B is classed A2L: it is hard to ignite, but regulations and the manufacturer call for monitoring. York has therefore mounted a factory sensor on the coil plate. This sensor is linked to the RDS control board. If the concentration approaches the set threshold (15% of the LFL), the call to the compressor is cut off and the indoor fan starts to dilute the air. There is no accessory to add: the protection is already in the coil.\u003c\/p\u003e\n\n\u003ch3\u003eThis 3.5-ton coil next to its three neighbours\u003c\/h3\u003e\n\u003cp\u003eHere is how we help customers decide between the models in the series, using only the published data:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCTF42C5CES1\u003c\/strong\u003e (this one): 3.5 tons, 21 in wide, TXV metering, R-454B.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTF48C5AFS1\u003c\/strong\u003e: 4 tons, 21 in wide, same metering and same refrigerant. Same width as ours, higher capacity.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTF48C5CFS1\u003c\/strong\u003e: 4 tons, 21 in, with a matched outdoor unit listed, the HH836E2S11.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTF48D5CFS1\u003c\/strong\u003e: 4 tons, 24-1\/2 in wide, for a wider furnace.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe practical conclusion: if your furnace is 21 in wide and the house is mid-sized, the 3.5-ton coil is the natural choice. If the house is larger, the 4-ton size is the one to look at, at the same 21 in width. And if the furnace is wider, think of the CTF48D5CFS1.\u003c\/p\u003e\n\n\u003ch3\u003eA concrete example\u003c\/h3\u003e\n\u003cp\u003eTake a family in Longueuil living in a mid-sized two-storey home, heated with electricity from an old furnace and with no air conditioning. They want to stop installing window air conditioners and cut their winter bill. The 3.5-ton coil goes on the existing furnace, a York heat pump of the same capacity is connected to it, and in a single project the house gets cool air in summer and more economical base heating in winter.\u003c\/p\u003e\n\u003cp\u003eAnother case, more common than you might think: a homeowner in Laval whose central air conditioner is at the end of its life. Because it runs on a different refrigerant, the coil cannot simply be swapped on its own; we install the coil and the outdoor unit together, designed to work with the same fluid.\u003c\/p\u003e\n\n\u003ch3\u003eOutdoor unit match and efficiency ratings\u003c\/h3\u003e\n\u003cp\u003eThis coil has no efficiency rating of its own. The SEER2, EER2 and HSPF2 values belong to the certified system, meaning a specific combination of coil and outdoor unit linked by an AHRI number. For this model, we confirm the AHRI number in the directory before ordering, so that the ratings shown in your quote are the ones you will actually get.\u003c\/p\u003e\n\u003cp\u003eYork publishes its matches with the HH8 heat pump on R-454B, with a variable-speed compressor. The liquid line is 3\/8 in, and larger diameters may be required when the distance between the units is long. We take all of this into account in the installation plan.\u003c\/p\u003e\n\n\u003ch3\u003eTo check before you buy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil is matched to an outdoor unit that uses the same refrigerant and is installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe 21 in width must match your furnace; if not, we build an insulated transition on site.\u003c\/li\u003e\n\u003cli\u003eThe blower must be able to deliver the system’s airflow, otherwise ice can form on the coil.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified match, not to the coil taken alone.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow we run the job\u003c\/h3\u003e\n\u003cp\u003eA visit is used first to measure the furnace, check the blower, examine the electrical panel and locate the return ducts. Then come:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003einstalling the coil in the plenum and sealing the duct connections;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit on a pad or bracket, the brazed piping, the nitrogen pressure test and the evacuation;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, setting the airflow and explaining how it all works, at your home, with you.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAirGreen is a family-run \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is carried out under our RBQ licence 5645-9605-01.\u003c\/p\u003e\n\n\u003ch3\u003eAbout York\u003c\/h3\u003e\n\u003cp\u003eYork is a residential brand of Johnson Controls, distributed in Quebec by Groupe Master. It makes central heat pumps, furnaces and the coils that go with them. The CTF, CTM and CTU coils on R-454B include the leak detection required for this refrigerant.\u003c\/p\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eEligibility for Hydro-Québec programs depends on the complete system, never on the coil alone. At the time of the quote, we check the match against the official list for your installation date, then tell you clearly what applies to your project.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":68402421956900,"sku":"CTF42C5CES1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_YORK_CTF_CTF42C5CES1_00_3_5_TONNES_42000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765671","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-york-ctf42c5ces1-a-3-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}