{"product_id":"serpentin-devaporateur-york-ctf48d5cfs1-a-4-tonnes","title":"YORK CTF48D5CFS1 Evaporator A-Coil | 4 Tons","description":"\u003ch2\u003eWide furnace, wide coil: the 4-ton, 24-1\/2 in York CTF48D5CFS1\u003c\/h2\u003e\n\u003cp\u003eOn a job site, the first question is almost never capacity. It is width. A large furnace, a blower cabinet roomier than average: if the coil does not line up with the plenum, everything gets complicated. The \u003cstrong\u003eCTF48D5CFS1\u003c\/strong\u003e is our York model for those cases. It measures 24-1\/2 in wide, while the other three coils in the series stay at 21 in.\u003c\/p\u003e\n\u003cp\u003eIt is an A-shaped evaporator coil, cased, of 4 tons (48,000 BTU\/h nominal), that runs on \u003cstrong\u003eR-454B\u003c\/strong\u003e. Our team installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eTake the tape measure first\u003c\/h3\u003e\n\u003cp\u003eMeasure the inside width of your plenum, or better, let us do it. If it is close to 24-1\/2 in, this model lines up naturally. If it is 21 in, the CTF48C5AFS1 or the CTF48C5CFS1 would be the better fit, offering the same nominal capacity in a narrower size.\u003c\/p\u003e\n\u003cp\u003eAnd what if the plenum matches none of the models exactly? We build an insulated transition on site. It is routine work, but the smaller the gap, the cleaner the installation.\u003c\/p\u003e\n\n\u003ch3\u003eThe dimensions of this model, one by one\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ewidth: 24-1\/2 in;\u003c\/li\u003e\n\u003cli\u003eheight: 27 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 58 lb, three pounds more than the 21 in version;\u003c\/li\u003e\n\u003cli\u003eliquid line connection: 3\/8 in;\u003c\/li\u003e\n\u003cli\u003esuction line connection: 7\/8 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis extra width gives the incoming air more face area. For the same nominal airflow of 1,600 CFM, the circulation is spread over a more generous surface. We take care not to promise a specific gain, however: the manufacturer does not publish one for this model.\u003c\/p\u003e\n\n\u003ch3\u003eThe same comfort engine as its siblings\u003c\/h3\u003e\n\u003cp\u003eApart from the width and the weight, the basic features are alike: 4-ton size, TXV metering, R-454B refrigerant, insulated cabinet, upflow or downflow installation. The choice is therefore made on the layout of your furnace rather than on the technology.\u003c\/p\u003e\n\n\u003ch3\u003eComparing in three lines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCTF42C5CES1\u003c\/strong\u003e: 3.5 tons, 21 in. For an average home.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTF48C5AFS1\u003c\/strong\u003e and \u003cstrong\u003eCTF48C5CFS1\u003c\/strong\u003e: 4 tons, 21 in. The second lists a matched outdoor unit, the HH836E2S11.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTF48D5CFS1\u003c\/strong\u003e (here): 4 tons, 24-1\/2 in, no matched unit listed on this page; we confirm it with the AHRI number before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow the coil works in your furnace\u003c\/h3\u003e\n\u003cp\u003eThe coil is installed in the plenum, in the path of the air. In summer, the refrigerant evaporates in its tubes and removes heat from the air passing through; the condensation is collected in a pan and sent to the drain. With a heat pump outside, the cycle reverses in winter and heat from outdoors is transferred into the air of the house. The furnace keeps its blower, its filters and its role as backup when the temperature falls below the agreed threshold.\u003c\/p\u003e\n\u003cp\u003eThis approach respects the existing duct network. No walls are drilled and no distribution is redone: we replace what makes the cold or the heat.\u003c\/p\u003e\n\n\u003ch3\u003eLeak detection from the factory\u003c\/h3\u003e\n\u003cp\u003eThe coil is delivered with an A2L sensor already fixed to the plate, which York’s manual associates with the RDS control board. If the reading exceeds 15% of the LFL, the call to the compressor is cut and the indoor blower turns on. This is what makes R-454B acceptable in a standard residential system.\u003c\/p\u003e\n\n\u003ch3\u003eEfficiency: what we can say and what we cannot\u003c\/h3\u003e\n\u003cp\u003eA coil has no SEER2, EER2 or HSPF2 of its own. These ratings are tied to a certified system, with an AHRI number. For the CTF48D5CFS1, we look for the match with a York outdoor unit of the same capacity, consult the directory and write the truly certified ratings into the quote. We would rather promise nothing than announce a figure that does not apply to your installation.\u003c\/p\u003e\n\u003cp\u003eYork publishes its matches starting from the HH8 heat pump on R-454B, variable speed. The liquid lines are 3\/8 in; for a long distance, larger diameters may be requested.\u003c\/p\u003e\n\n\u003ch3\u003eThe CTF48D5CFS1 in the daily life of a large home\u003c\/h3\u003e\n\u003cp\u003eIn a multi-storey home in Laval, a finished basement can stay cool while the upper floor is stifling, or the other way around. A 4-ton system with an adequate blower helps balance this. In the newer neighbourhoods of the South Shore or the North Shore, large furnaces are common: that is where the width of this coil makes the most sense.\u003c\/p\u003e\n\u003cp\u003eIn summer, a single outdoor unit replaces window air conditioners; in winter, the heat pump supplies most of the heating and the furnace serves as a supplement.\u003c\/p\u003e\n\n\u003ch3\u003eBefore calling us, check this\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ethe coil is matched to an outdoor unit that uses the same refrigerant and is installed with it;\u003c\/li\u003e\n\u003cli\u003ethe furnace width allows 24-1\/2 in, or a reasonable transition;\u003c\/li\u003e\n\u003cli\u003ethe blower can deliver the airflow needed;\u003c\/li\u003e\n\u003cli\u003ethe published ratings belong to the certified match.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eWe measure the furnace, check the blower and the electrical panel, install the coil in the plenum and seal the duct connections. The outdoor unit is mounted on a pad or bracket; the brazed piping undergoes a nitrogen pressure test before evacuation. The condensate drain and the thermostat are connected, then we set the airflow and show you how it works on site.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family-run \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company in Montreal for more than fifteen years, under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\n\u003ch3\u003eAbout York and the warranty\u003c\/h3\u003e\n\u003cp\u003eYork is a Johnson Controls brand, distributed in Quebec by Groupe Master. The manufacturer offers a 10-year limited parts warranty on this coil.\u003c\/p\u003e\n\n\u003ch3\u003eThe width mistakes we see most often\u003c\/h3\u003e\n\u003cp\u003eThe first is ordering on capacity alone. Four tons, very well, but for which furnace size? The second is relying on an outside measurement of the cabinet: the plenum opening is what determines what the coil can receive. The third is neglecting vertical clearance, because the 27 in high cabinet must fit without cutting into access to the filters.\u003c\/p\u003e\n\u003cp\u003eThat is why our assessment visit begins with these measurements. We take the time to note every dimension, photograph the mechanical room and validate it all against the installation plan before placing the order.\u003c\/p\u003e\n\u003ch3\u003eWhat you will receive in the quote\u003c\/h3\u003e\n\u003cp\u003eA written document specifies the coil model, the selected outdoor unit, the AHRI number of the match once verified, the planned work and any adaptations, such as the plenum transition. You thus know, before signing, what is included and what could change the price.\u003c\/p\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs apply to the complete system. We check the match on the official list at the time of the quote and tell you what applies to your project.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":68402471600420,"sku":"CTF48D5CFS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_YORK_CTF_CTF48D5CFS1_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765670","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-york-ctf48d5cfs1-a-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}