{"product_id":"serpentin-devaporateur-york-ctf60d5cgs1-a-5-tonnes","title":"YORK CTF60D5CGS1 Evaporator A-Coil | 5 Tons","description":"\u003ch2\u003eCTF60D5CGS1: the 24-1\/2 in. York coil, compact in height, for a wide furnace\u003c\/h2\u003e\n\u003cp\u003eA wide furnace, a low plenum, a big house to cool: the \u003cstrong\u003eYork CTF60D5CGS1 evaporator coil\u003c\/strong\u003e was designed for that kind of combination. At 24-1\/2 in. wide and 32-3\/4 in. high, this cased 5-ton (60,000 BTU\/h) A-coil takes up more width than the 21 in. models, but it stays short in height, which makes installation easier when the clearance above the furnace is limited.\u003c\/p\u003e\n\u003cp\u003eWe install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. Read what follows before comparing quotes.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently asked questions about this model\u003c\/h3\u003e\n\u003ch4\u003eCan it heat, or only cool?\u003c\/h4\u003e\n\u003cp\u003eThat depends on the outdoor unit. Paired with a heat pump, it cools in summer and heats in winter. With a central air conditioner, it only provides cooling.\u003c\/p\u003e\n\u003ch4\u003eCan I keep my current air conditioner?\u003c\/h4\u003e\n\u003cp\u003eGenerally, no. The coil runs on R-454B and must be paired with the outdoor unit specified by the manufacturer. We install the complete system.\u003c\/p\u003e\n\u003ch4\u003eMy furnace is a different width. What can be done?\u003c\/h4\u003e\n\u003cp\u003eWe measure it and, if needed, build an insulated transition on site.\u003c\/p\u003e\n\u003ch4\u003eIs the furnace still useful?\u003c\/h4\u003e\n\u003cp\u003eYes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the threshold set with you.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is inside the cabinet\u003c\/h3\u003e\n\u003cp\u003eThe CTF60D5CGS1 ships in an insulated cabinet, ready to sit on the furnace or on a blower cabinet. Here are the essentials of its specification sheet:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003edimensions (W × H × D): 24-1\/2 × 32-3\/4 in.;\u003c\/li\u003e\n\u003cli\u003enet weight: 66 lb;\u003c\/li\u003e\n\u003cli\u003erated airflow: 1,800 CFM;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in. for the liquid line, 7\/8 in. for the suction line;\u003c\/li\u003e\n\u003cli\u003emetering device: TXV;\u003c\/li\u003e\n\u003cli\u003einstallation positions: upflow or downflow;\u003c\/li\u003e\n\u003cli\u003emanufacturer's warranty: 10-year limited parts warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe A-coil forms an inverted roof in the plenum. The air rises to the centre, passes through the two faces and leaves cooled. This shape is the most common on upflow furnaces.\u003c\/p\u003e\n\n\u003ch3\u003eTwo certified pairings, two heating profiles\u003c\/h3\u003e\n\u003cp\u003eLike the CTF60C5CGS1, this model is published with two outdoor units from the York HH8 series. The ratings belong to the systems, not to the coil alone:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHH860E2S11\u003c\/strong\u003e, AHRI 214606579: cooling 44,500 BTU\/h, heating 46,000 BTU\/h at 47 °F, SEER2 15.2, HSPF2 8.5;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHH860E2S12\u003c\/strong\u003e, AHRI 218697633: cooling 44,500 BTU\/h, heating 45,500 BTU\/h at 47 °F, SEER2 15.2, HSPF2 8.1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth offer the same cooling capacity. The first shows a somewhat higher HSPF2 and slightly more heating at 47 °F. The second is the two-stage unit that York matches with CT*60*G coils. York also specifies that most of these pairings are certified for cold climates, with a few exceptions noted in its documents. We confirm the exact AHRI number for you before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eWhy talk about the AHRI number?\u003c\/h3\u003e\n\u003cp\u003eBecause it is the only reliable way to compare two offers. A coil has no efficiency rating of its own; SEER2, EER2 and HSPF2 attach to a specific combination of a coil and an outdoor unit. Without the number, you are comparing promises. With it, you are comparing tested systems. It is also the number used for rebate programs.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing within the series: where does the D5CGS1 stand?\u003c\/h3\u003e\n\u003cp\u003eThe five 5-ton CTF coils share the A shape, the cabinet, R-454B and the TXV. Here is how to place this one:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eAgainst the 21 in. models\u003c\/strong\u003e (CTF60C5CGS1 and CTF60C5CHS1): it is several inches wider. Choose it if the furnace is wide, to avoid a transition that narrows the passage.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAgainst the CTF60D5CHS1 and CTF60D5CJS1\u003c\/strong\u003e, of the same width: the CTF60D5CHS1 is taller and heavier; the CTF60D5CJS1 has the same 24-1\/2 × 32-3\/4 in. dimensions but is heavier than this one.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePairing:\u003c\/strong\u003e the CTF60D5CGS1 is one of the two models in the series that list two outdoor units, along with the CTF60C5CGS1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePlanning the installation when the furnace is wide\u003c\/h3\u003e\n\u003cp\u003eA wide furnace has an advantage: the air moves across a larger section, which limits the speed at the internal grilles. But it also means checking that the cabinet sits flat, that the plenum opening is clear and that the condensate drain can run down with a steady slope. We check those three points during the visit. We also look at where the refrigerant lines will run between the coil and the outdoor unit, to avoid pointless detours in the basement.\u003c\/p\u003e\n\u003cp\u003eIn homes in Laval or on the North Shore where the service area is open, installation is generally done without reworking the ducts. In older bungalows in Montreal or Longueuil, the utility room can be tight: that is when this model's reduced height makes the difference.\u003c\/p\u003e\n\n\u003ch3\u003eThe leak sensor that comes with R-454B\u003c\/h3\u003e\n\u003cp\u003eThis refrigerant is A2L class. York therefore fits a factory-installed sensor (code S) on the coil plate, connected to the RDS control board. Above 15% of the LFL, the call to the compressor is cut and the indoor fan turns on. The procedure is described in manual 6356510-UIM-C-0824.\u003c\/p\u003e\n\n\u003ch3\u003eWhat it means for your bill and your comfort\u003c\/h3\u003e\n\u003cp\u003eAn electric furnace converts every kilowatt-hour into an equal amount of heat. A heat pump, on the other hand, moves outdoor heat into the house: in mild weather, it delivers two to three times more than the electricity it consumes. That efficiency drops with the cold, hence the furnace's backup role. In summer, the same equipment replaces window air conditioners and dries the air.\u003c\/p\u003e\n\u003cp\u003eAt this size, two checks are essential: the electrical service, which must handle the outdoor unit's circuit, and the air distribution. York indicates roughly 350 to 450 CFM per ton of outdoor unit and an external static pressure of 0.2 to 0.6 in. w.c. If the house is not suited to it, we say so frankly: two smaller systems may be a better fit.\u003c\/p\u003e\n\n\u003ch3\u003eOur work, from the visit to commissioning\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company, in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum and sealing the connections;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit, brazed piping, nitrogen test, evacuation;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003eairflow adjustment and an explanation of how everything works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eBefore you order\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B requires an outdoor unit using the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to a specific matched system.\u003c\/li\u003e\n\u003cli\u003eThe furnace width and the blower capacity are confirmed on site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe matched York system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it against the official list at quote time and prepare the application with you.\u003c\/p\u003e\n\n\u003ch3\u003eGet a written quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":68402455707940,"sku":"CTF60D5CGS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_YORK_CTF_CTF60D5CGS1_00_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765671","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-york-ctf60d5cgs1-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}