{"product_id":"serpentin-devaporateur-york-ctf60d5chs1-a-5-tonnes","title":"YORK CTF60D5CHS1 Evaporator A-Coil | 5 Tons","description":"\u003ch2\u003eYork CTF60D5CHS1: the biggest coil in the series, 24-1\/2 in. wide and 74 lb\u003c\/h2\u003e\n\u003cp\u003eIn the family of 5-ton CTF coils, the \u003cstrong\u003eCTF60D5CHS1\u003c\/strong\u003e is the most imposing: 24-1\/2 in. wide, 37-1\/4 in. high, 74 lb net. It is a cased A-coil rated at 5 tons (60,000 BTU\/h), running on R-454B refrigerant. It targets the large furnace, the large plenum and the large house, where you want a big heat-exchange surface and a certified high-capacity system.\u003c\/p\u003e\n\u003cp\u003eThis page is written for homeowners in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e who are comparing several York coils and want to understand what really changes from one model to the next.\u003c\/p\u003e\n\n\u003ch3\u003eWhat you gain with a big cabinet\u003c\/h3\u003e\n\u003cp\u003eA wider, taller cabinet holds a more generous coil. The CTF60D5CHS1 lists a rated airflow of 1,800 CFM. It ships insulated, ready to sit on the furnace, with a TXV metering device that adjusts the refrigerant feed. The connections are 3\/8 in. for the liquid line and 7\/8 in. for the suction line, and the manufacturer publishes two installation positions: upflow or downflow.\u003c\/p\u003e\n\u003cp\u003eThis size does come at a cost in space, though: it needs room, in both width and height, and the plenum must be able to carry the cabinet's weight.\u003c\/p\u003e\n\n\u003ch3\u003eThe checklist before the visit\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\u003cstrong\u003eFurnace width.\u003c\/strong\u003e Ideally 24-1\/2 in. If it is narrower, we build an insulated transition on site.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAvailable height.\u003c\/strong\u003e The cabinet measures 37-1\/4 in. It must fit under the obstacles in the utility room, beams and pipes included.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStrength of the support.\u003c\/strong\u003e At 74 lb, the cabinet rests on the furnace: we check that its top is flat and in good condition.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eElectrical service.\u003c\/strong\u003e The outdoor unit's circuit must have room there.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBlower and ducts.\u003c\/strong\u003e They must deliver the airflow the system calls for.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eA single pairing, high ratings\u003c\/h3\u003e\n\u003cp\u003eYork publishes a single certified system for this coil:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eoutdoor unit \u003cstrong\u003eHH860E2S11\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003eAHRI number 214606580;\u003c\/li\u003e\n\u003cli\u003ecooling 54,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003eheating 55,000 BTU\/h at 47 °F;\u003c\/li\u003e\n\u003cli\u003eSEER2 15.2, HSPF2 8.1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HH8 series is an R-454B heat pump with a variable-speed compressor, ENERGY STAR certified for Canada and the United States. In this pairing, the published cooling and heating capacities are higher than those of the systems matched with the CTF60C5CGS1 and CTF60D5CGS1: that is one of the arguments for choosing it if your home is large.\u003c\/p\u003e\n\u003cp\u003eAn important point: the coil has no efficiency rating on its own. SEER2, EER2 and HSPF2 are read from the complete system, linked by its AHRI number.\u003c\/p\u003e\n\n\u003ch3\u003eThe CTF60D5CHS1 compared with its neighbours\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eAgainst the CTF60D5CGS1 and CTF60D5CJS1\u003c\/strong\u003e (same width): they are lower. If the plenum is limited in height, one of those two models is a better fit.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAgainst the CTF60C5CHS1\u003c\/strong\u003e (same 37-1\/4 in. height, 21 in. width): they have the same vertical profile, but this one is wider. The choice depends on the furnace width.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAgainst the CTF60C5CGS1:\u003c\/strong\u003e this is the opposite, the narrowest and lightest in the series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll share the A shape, the cabinet, the TXV and R-454B; all have the HH860E2S11 as their main outdoor unit. The CTF60D5CHS1 is the heaviest of the group.\u003c\/p\u003e\n\n\u003ch3\u003eThree scenarios where this model makes sense\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe large multi-storey house.\u003c\/strong\u003e A two-storey home with a finished basement calls for a lot of cool air in July. A well-ducted 5-ton system avoids putting window air conditioners in the upstairs bedrooms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe electric furnace to replace.\u003c\/strong\u003e You heat with electricity and the furnace is wide. By adding a heat pump, you keep your ducts, your blower and your thermostat, and you reduce reliance on the heating elements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe old central air conditioner on its last legs.\u003c\/strong\u003e Because R-454B does not mix with the old refrigerant, we replace the outdoor unit and the coil together. It is a chance to move to a complete certified system, with its AHRI number.\u003c\/p\u003e\n\n\u003ch3\u003eMaintenance: what stays simple\u003c\/h3\u003e\n\u003cp\u003eA large coil does not mean complicated maintenance, quite the opposite.\u003c\/p\u003e\n\u003cp\u003eThe coil asks almost nothing of a homeowner. Change the filter as your furnace recommends, keep the registers clear and check from time to time that the condensate drain flows well. A technician can inspect the pan and the sensor during a routine service visit. With a big cabinet like this one, we leave enough clearance for that inspection to stay easy.\u003c\/p\u003e\n\n\u003ch3\u003eHow the coil works in your home\u003c\/h3\u003e\n\u003cp\u003eThe blower sends the house air to the centre of the A. It passes through the two faces and gives up its heat to the cold refrigerant. The moisture condenses in the pan and runs out through the drain. In summer, you get cool, dry air in every room served by your ducts.\u003c\/p\u003e\n\u003cp\u003eWith a heat pump, the cycle reverses in winter. The furnace keeps its heating elements: it takes over below the temperature threshold we set with you.\u003c\/p\u003e\n\n\u003ch3\u003eThe R-454B leak sensor\u003c\/h3\u003e\n\u003cp\u003eR-454B is an A2L refrigerant. The coil includes a factory-installed sensor (code S), mounted on the coil plate and wired to the RDS control board. If the concentration exceeds 15% of the LFL, the call to the compressor is cut and the indoor fan starts. See the manufacturer's manual 6356510-UIM-C-0824.\u003c\/p\u003e\n\n\u003ch3\u003eDo you really need five tons?\u003c\/h3\u003e\n\u003cp\u003eThe 5-ton size is the largest common residential size. It suits large homes, finished basements and extensions. It is mostly justified when the air distribution can keep up: York mentions roughly 350 to 450 CFM per ton of outdoor unit, with an external static pressure of 0.2 to 0.6 in. w.c. If your ducts are too restrictive, we will tell you, and we then talk about two smaller systems.\u003c\/p\u003e\n\u003cp\u003eAn electric furnace produces as much heat as the energy it consumes. A heat pump moves heat: in mild weather, it provides two to three times more than the electricity it uses. That efficiency drops with the cold, hence the furnace's backup role.\u003c\/p\u003e\n\n\u003ch3\u003eOur installation\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the cabinet in the plenum and sealing the connections;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit, brazed piping, nitrogen test, evacuation;\u003c\/li\u003e\n\u003cli\u003econnecting the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment, explanations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe manufacturer offers a 10-year limited parts warranty.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe matched York system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it against the official list at quote time and prepare the application with you.\u003c\/p\u003e\n\n\u003ch3\u003eTake the next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":68402471633188,"sku":"CTF60D5CHS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_YORK_CTF_CTF60D5CHS1_00_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765672","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-york-ctf60d5chs1-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}