{"product_id":"serpentin-devaporateur-york-ctm24b5abs1-a-2-tonnes","title":"YORK CTM24B5ABS1 Evaporator A-Coil | 2 Tons","description":"\u003ch2\u003eCTM24B5ABS1: 2 tons in a cabinet 17-1\/2 in wide, for the furnace that does not fit the mould\u003c\/h2\u003e\n\u003cp\u003eNot every furnace has the same width. When yours goes beyond the usual size, the \u003cstrong\u003eYork CTM24B5ABS1 evaporator coil\u003c\/strong\u003e spares you a lot of acrobatics. This cased A-coil from the York CTM range delivers 2 tons (24,000 BTU\/h) and measures 17-1\/2 in wide. It runs on R-454B. AirGreen installs it in the \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and \u003cstrong\u003eSouth Shore\u003c\/strong\u003e areas.\u003c\/p\u003e\n\n\u003ch3\u003eWhy width matters so much\u003c\/h3\u003e\n\u003cp\u003eThe coil sits on top of the furnace. If the cabinet is narrower than the plenum, the air finds ways to leak; if it is wider, it overhangs. That is why it pays to choose a width close to yours. Here, it is 17-1\/2 in by 23 in high. When a gap remains anyway, we build an insulated transition right at your home.\u003c\/p\u003e\n\n\u003ch3\u003eWhat 2 tons means for your home\u003c\/h3\u003e\n\u003cp\u003eThe 2-ton size is found in townhouses, compact bungalows and some plex units. We offer it only after calculating the load. A unit stronger than necessary starts and stops constantly, leaves moisture in place and wears out its components. It is better to have a size matched to your needs than a unit chosen out of habit.\u003c\/p\u003e\n\n\u003ch3\u003eA sample house\u003c\/h3\u003e\n\u003cp\u003eImagine a townhouse in Longueuil whose furnace, wider than average, takes up almost the whole basement alcove. The load calculation points to 2 tons. The narrower CTM24A5ABS1 would require a transition to cover the opening. The CTM24B5ABS1, at 17-1\/2 in, fits the plenum better. Fewer custom parts, fewer joints to seal, and a cleaner installation.\u003c\/p\u003e\n\n\u003ch3\u003eWhat you will feel day to day\u003c\/h3\u003e\n\u003cp\u003eWhen the capacity matches the load, the system runs for a long time at low speed. The air is more even from room to room and the summer humidity drops noticeably. With a heat pump, winter brings the same gentle heat through the existing vents, and the furnace waits its turn for the deep cold.\u003c\/p\u003e\n\n\u003ch3\u003eWeight, a reassuring detail\u003c\/h3\u003e\n\u003cp\u003eDespite its width, the CTM24B5ABS1 weighs 38 lb net, which is less than its narrower neighbour of the same capacity. For the crew carrying the unit down a basement staircase, this is noticeable.\u003c\/p\u003e\n\n\u003ch3\u003eThe coil up close\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: CTM24B5ABS1, cased coil;\u003c\/li\u003e\n\u003cli\u003enominal capacity: 2 tons, 24,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003edimensions: 17-1\/2 × 23 in;\u003c\/li\u003e\n\u003cli\u003emetering device: TXV;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid, 3\/4 in suction;\u003c\/li\u003e\n\u003cli\u003enominal airflow: 800 CFM;\u003c\/li\u003e\n\u003cli\u003epositions: upflow, downflow, horizontal left or right;\u003c\/li\u003e\n\u003cli\u003ewarranty: 10-year limited warranty on parts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe role of the TXV\u003c\/h3\u003e\n\u003cp\u003eThe TXV is a thermostatic expansion valve. It lets into the coil just the amount of refrigerant that the warm air needs. In a heat wave, it opens wider; in the shoulder seasons, it closes down. The coil stays well fed without flooding the compressor.\u003c\/p\u003e\n\n\u003ch3\u003eBuilt-in leak detection\u003c\/h3\u003e\n\u003cp\u003eR-454B is an A2L refrigerant, which requires a detector. The one on the CTM24B5ABS1 is factory-installed (code S), on the coil plate, and connected to the RDS control board. When the concentration passes 15% of the LFL, the call for the compressor stops and the indoor fan starts up, to dilute the air.\u003c\/p\u003e\n\n\u003ch3\u003eThe outdoor unit that goes with it\u003c\/h3\u003e\n\u003cp\u003eThis coil pairs with a York outdoor unit of the same capacity and the same refrigerant. Among the models published by York is the HH8 heat pump (LX series) using R-454B, variable-speed, ENERGY STAR certified for Canada and the United States. A heat pump of this type can heat in winter through the same ducts that cool in summer; with a central air conditioner, the coil only cools.\u003c\/p\u003e\n\u003cp\u003eThe efficiency ratings (SEER2, EER2, HSPF2) attach not to the coil alone but to the certified combination, identified by an AHRI number. We look up that number before placing the order so that the figures promised are the ones you will get.\u003c\/p\u003e\n\n\u003ch3\u003ePlacing this coil among its siblings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCTM18A5AAS1\u003c\/strong\u003e: 1.5 tons, 14-1\/2 in. For small volumes.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTM24A5ABS1\u003c\/strong\u003e: 2 tons, 14-1\/2 in. Same capacity as this one, but for a narrower furnace.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTM24B5ABS1\u003c\/strong\u003e: 2 tons, 17-1\/2 in. This page.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll three run on R-454B, with a TXV and a cabinet. The only thing separating the two 2-ton models is width: 14-1\/2 in versus 17-1\/2 in. Measure your furnace, or let us do it, and the answer becomes obvious.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we do on installation day\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. Our crew:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasures the furnace and checks the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003esets the coil in the plenum and seals the duct connections;\u003c\/li\u003e\n\u003cli\u003einstalls the outdoor unit, brazes the piping, runs the nitrogen test and pulls the vacuum;\u003c\/li\u003e\n\u003cli\u003econnects the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003esets the airflow, which sits around 350 to 450 CFM per ton of the outdoor unit, and explains the whole system to you.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eQuestions people ask us\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my current air conditioner?\u003c\/strong\u003e Generally not. The coil runs on R-454B and must be paired with the outdoor unit specified by the manufacturer. We install the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still useful?\u003c\/strong\u003e Yes. It keeps its blower and provides backup when it is too cold outside for the heat pump alone.\u003c\/p\u003e\n\n\u003ch3\u003eCheckpoints before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe same refrigerant on both sides, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eRatings valid for the certified match only.\u003c\/li\u003e\n\u003cli\u003eA furnace of the right width, with a blower able to deliver the system's airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA word on noise and air\u003c\/h3\u003e\n\u003cp\u003eA cabinet better fitted to the furnace reduces whistling at the joints, and a properly set blower avoids unpleasant drafts at the vents. These are details that appear on no spec sheet, but that you will notice from the first week, especially if your living rooms are close to the furnace.\u003c\/p\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs apply to the complete system, never to the coil alone. We check your match against the official list according to the installation date and explain what applies.\u003c\/p\u003e\n\n\u003ch3\u003eWhy use an installer rather than going it alone\u003c\/h3\u003e\n\u003cp\u003eA coil is only one part of the system. The match, the refrigerant charge, the vacuum, the airflow and the drain decide the lifespan of the whole. By entrusting everything to a single crew, you avoid the back-and-forth between the seller, the electrician and the refrigeration technician, and you know whom to call back if an adjustment needs to be revisited after the first season.\u003c\/p\u003e\n\u003cp\u003eWe also go over the basics with you: where the filter is, how to read the thermostat, which noise is normal and which one deserves a call.\u003c\/p\u003e\n\n\u003ch3\u003eLet us take the measurements\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":68402460360996,"sku":"CTM24B5ABS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_YORK_CTM_CTM24B5ABS1_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765673","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-york-ctm24b5abs1-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}