{"product_id":"serpentin-devaporateur-york-ctm36b5ads1-a-3-tonnes","title":"YORK CTM36B5ADS1 Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003eCTM36B5ADS1: the 17-1\/2 in York coil and its certified match\u003c\/h2\u003e\n\u003cp\u003eOf the 3-ton York coils we install, the \u003cstrong\u003eCTM36B5ADS1\u003c\/strong\u003e is the one whose match sheet shows the highest ratings in its series. The system it forms with the \u003cstrong\u003eHH824E2S11\u003c\/strong\u003e outdoor unit carries AHRI number 216010725, with a SEER2 and HSPF2 of 19.0 \/ 9.5. It is a cased A-coil, 17-1\/2 in wide, that runs on R-454B refrigerant. It is mostly of interest to homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore who have a gas, oil or electric furnace in good condition and want to add air conditioning, or even heat pump heating.\u003c\/p\u003e\n\n\u003ch3\u003eWhat this model does in your home\u003c\/h3\u003e\n\u003cp\u003eAn evaporator coil is the heat exchanger that sits in the plenum, right above the furnace. Air from the house passes through it, gives up its heat to the refrigerant circulating in the tubes, then goes back out through the vents, cooled. Without it, the outdoor unit is useless: it is the indoor half of the circuit.\u003c\/p\u003e\n\u003cp\u003eThe CTM36B5ADS1 belongs to York's CTM range. Its nominal size is 3 tons, or 36,000 BTU\/h. It is a multi-position model: it can be mounted upflow, downflow or horizontal, left or right, which leaves some room to work with depending on where your furnace is installed.\u003c\/p\u003e\n\n\u003ch3\u003eReading the AHRI number before you sign a quote\u003c\/h3\u003e\n\u003cp\u003eHere is a detail few people know: a coil has no efficiency rating on its own. Ratings belong to a pair, one specific coil and one specific outdoor unit, and the AHRI number is what links them. For this model, the number to keep is 216010725. It matches the York HH824E2S11 outdoor unit, an LX series heat pump on R-454B with a variable-speed compressor.\u003c\/p\u003e\n\u003cp\u003eWhen you compare two quotes, ask each contractor for this number. Two prices can look equivalent when one describes a certified match and the other an assembly of parts whose ratings nobody guarantees. With us, the number is on the quote, and we check it in the directory before ordering.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCooling for the match: 23,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003eheating at 47 °F: 23,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003eSEER2 \/ HSPF2: 19.0 \/ 9.5.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA slim size for compact furnaces\u003c\/h3\u003e\n\u003cp\u003eAt 17-1\/2 in wide, the CTM36B5ADS1 is aimed at modest-sized furnaces, the kind found in a laundry room, a small basement or a blower cabinet squeezed between two walls. Its full dimensions are 17-1\/2 × 25-5\/8 in, and it weighs 50 lb net. A narrower coil slides into a tight space more easily, but it still has to match the plenum opening.\u003c\/p\u003e\n\u003cp\u003eIf your furnace is wider, we build an insulated transition on site. This is not a makeshift repair: it is a routine job, done with the same care as the rest of the installation, and sealing the connections is part of the work.\u003c\/p\u003e\n\n\u003ch3\u003eHow to choose between this model and its three siblings\u003c\/h3\u003e\n\u003cp\u003eThe series has four 3-ton models, all cased, all on R-454B and all with a TXV metering device. What sets them apart comes down to two things: the width and the outdoor unit.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCTM36B5ADS1\u003c\/strong\u003e, the one on this page: 17-1\/2 in, matched to the HH824E2S11 unit;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTM36B5CDS1\u003c\/strong\u003e: also 17-1\/2 in, but matched to the HH836E2S11 unit;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTM36C5ADS1\u003c\/strong\u003e: 21 in wide, with no outdoor unit specified in our file;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTM36C5CDS1\u003c\/strong\u003e: 21 in wide, matched to the HH836E2S11 unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe rule is simple. First measure the width of your plenum: 17-1\/2 in or 21 in. Only then discuss the match with the outdoor unit. If the width of your furnace points you toward 17-1\/2 in, the question becomes: HH824E2S11 or HH836E2S11? We go over it on site, with the ratings of each in front of us.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the furnace keeps, what it gives up\u003c\/h3\u003e\n\u003cp\u003eOn a system like this, the furnace does not go away. It keeps its blower, its filters and the existing ductwork. In summer, the blower pushes air through the coil and the house cools down. In winter, if the outdoor unit is a heat pump, the cycle reverses and the refrigerant brings heat to the air; the furnace only takes over when the outdoor temperature drops below the threshold we set with you.\u003c\/p\u003e\n\u003cp\u003eIn practice, you can turn an electric furnace into a central heat pump, replace an old central air conditioner with a new system, or keep your furnace as backup heat for the coldest days. In all three cases, the coil sits in the same place and does the same job.\u003c\/p\u003e\n\n\u003ch3\u003eA refrigerant leak can be detected\u003c\/h3\u003e\n\u003cp\u003eR-454B belongs to the A2L family of refrigerants, which call for special monitoring. York has therefore built in a factory-installed A2L sensor (code S) on the coil plate. It is wired to the RDS control board: above 15% of the LFL, the call to the compressor is cut and the indoor fan is switched on to circulate the air. It is a passive safeguard that you do not have to manage, but it is good to know it exists.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: York, CTM range;\u003c\/li\u003e\n\u003cli\u003etype: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003enominal size: 3 tons (36,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003emetering device: TXV;\u003c\/li\u003e\n\u003cli\u003enominal airflow: 1,200 CFM;\u003c\/li\u003e\n\u003cli\u003eliquid connection: 3\/8 in; suction connection: 3\/4 in;\u003c\/li\u003e\n\u003cli\u003edimensions W × H × D: 17-1\/2 × 25-5\/8 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 50 lb;\u003c\/li\u003e\n\u003cli\u003ewarranty: 10-year limited parts warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAirflow deserves a word. York publishes about 350 to 450 CFM per ton of the outdoor unit, with an external static pressure of 0.2 to 0.6 in. W.C. This means your blower and ductwork must be able to deliver that volume of air. That is exactly what we check at the visit.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we do on installation day\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, and our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. For this coil and its outdoor unit, here is how it goes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, with a transition built on site if needed, and sealing the duct connections;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit on a pad or bracket, brazed piping, nitrogen leak test and vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and a walk-through of how it works at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe liquid line for the match is 3\/8 in; for long distances between the outdoor unit and the coil, larger lines may be required, and we include that in the quote.\u003c\/p\u003e\n\n\u003ch3\u003eFive checks before you order\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil uses R-454B: the outdoor unit must use the same refrigerant and be installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified match with the outdoor unit specified by the manufacturer.\u003c\/li\u003e\n\u003cli\u003eThe 17-1\/2 in width must suit your furnace.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the system's airflow.\u003c\/li\u003e\n\u003cli\u003eYour old air conditioner generally cannot be reused: it does not work with this refrigerant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert subsidy\u003c\/h3\u003e\n\u003cp\u003eThe matched York system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check it against the official list when we prepare the quote and put the application together with you, so you know what to expect before you say yes.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":68402461901092,"sku":"CTM36B5ADS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_YORK_CTM_CTM36B5ADS1_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765674","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-york-ctm36b5ads1-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}